Detection of circulating tumour cells in blood by quantitative real-time RT-PCR: effect of pre-analytical time.

Benoy Ina H, Elst Hilde, Van Dam Peter, Scharpe Simon, Van Marck Eric, Vermeulen Peter, Dirix Luc

Publication: Clin Chem Lab Med (2006) • Vol 44 • Page 1082PMID: 16958599View on PubMed

Purpose

The purpose of this paper was to determine if storage of blood samples at room temperature for various durations (0-72 h) impacts RNA quality and mRNA levels of breast cancer tumor marker genes.

Conclusion

RNA quality began to deteriorate after 6 h of storage at room temperature. Detectable mRNA levels of CK-19, beta-actin, and GAPH declined significantly beginning 4 h after storage at room temperature. VEGF expression increased after 24 h at room temperature, while MAM expression remained stable for up to 6 h. mRNA levels were not affected by sequential blood collection. Authors recommend room temperature storage of blood samples be limited to 3 h or less.

Studies (3)

Purpose

The purpose of this study was to determine if storage of blood samples at room temperature (0-72 h) impacts RNA quality.

Summary of Findings

RNA quality, as determined by the presence of distinct 28S and 18S ribosomal peaks and their ratio, began to deteriorate after 6 h of storage at room temperature.
  • Biospecimens

    FluidBlood
  • Preservation Types

    None (Fresh)
  • Diagnoses

    Normal
    Neoplastic
  • Platforms

    RNAElectrophoresis
  • Pre-analytical Factors

    ClassificationPre-Analytical FactorValue(s)
    StorageTime at room temperature
    0 h
    1 h
    2 h
    24 h
    4 h
    48 h
    6 h
    72 h