Detection of circulating tumour cells in blood by quantitative real-time RT-PCR: effect of pre-analytical time.
Benoy Ina H, Elst Hilde, Van Dam Peter, Scharpe Simon, Van Marck Eric, Vermeulen Peter, Dirix Luc
Purpose
The purpose of this paper was to determine if storage of blood samples at room temperature for various durations (0-72 h) impacts RNA quality and mRNA levels of breast cancer tumor marker genes.
Conclusion
RNA quality began to deteriorate after 6 h of storage at room temperature. Detectable mRNA levels of CK-19, beta-actin, and GAPH declined significantly beginning 4 h after storage at room temperature. VEGF expression increased after 24 h at room temperature, while MAM expression remained stable for up to 6 h. mRNA levels were not affected by sequential blood collection. Authors recommend room temperature storage of blood samples be limited to 3 h or less.
Studies (3)
Purpose
The purpose of this study was to determine if storage of blood samples at room temperature (0-72 h) impacts RNA quality.
Summary of Findings
RNA quality, as determined by the presence of distinct 28S and 18S ribosomal peaks and their ratio, began to deteriorate after 6 h of storage at room temperature.
Biospecimens
FluidBloodPreservation Types
None (Fresh)Diagnoses
NormalNeoplasticPlatforms
RNAElectrophoresisPre-analytical Factors
Classification Pre-Analytical Factor Value(s) Storage Time at room temperature 0 h1 h2 h24 h4 h48 h6 h72 h
Purpose
To determine if storage of blood samples at room temperature (0-72 hr) impacts mRNA levels of breast cancer tumor markers (GAPDH, beta-actin, CK19, HER2, VEGF) as measured by real time quantitative RT-PCR.
Summary of Findings
Altered mRNA levels resultant from room temperature storage were marker and time-dependent. Expression significantly decreased for CK-19 and HER-2 after 4 h, beta-actin after 6 h, and GAPDH after 24 h. MAM expression appeared stable for up to 6 h in the two samples with detectable expression. VEGF expression significantly increased after 24 h at room temperature compared to time 0 h controls.
Biospecimens
FluidBloodPreservation Types
None (Fresh)Diagnoses
NormalNeoplasticPlatforms
RNAReal-time qRT-PCRPre-analytical Factors
Classification Pre-Analytical Factor Value(s) Storage Time at room temperature 0 h1 h2 h24 h4 h48 h6 h72 hReal-time qRT-PCR Specific Targeted nucleic acid CK-19GAPDHHER-2MAMVEGFbeta-actin
Purpose
To determine whether mRNA expression levels vary as a result of sequential blood collection.
Summary of Findings
No difference in CK-19, HER-2, or VEGF was observed among 3 ml blood samples collected sequentially.
Biospecimens
FluidBloodPreservation Types
None (Fresh)Diagnoses
NeoplasticNormalPlatforms
RNAReal-time qRT-PCRPre-analytical Factors
Classification Pre-Analytical Factor Value(s) Biospecimen Aliquots and Components Aliquot sequential collection FirstSecondReal-time qRT-PCR Specific Targeted nucleic acid CK-19HER-2VEGF