Skip to main content

Effects of Preanalytical Factors on the Molecular Size of Cell-Free DNA in Blood.

Chan K, Yeung S, Lui W, Rainter T, Lo YM

Publication: Clin Chem (2005) • Vol 51 • Page 781PMID: 15708950View on PubMed

Purpose

The purpose of this paper was to investigate the impact of (1) clotting, (2) delayed separation of blood cells from plasma, (3 and 4) freeze thaw cycling of both plasma and DNA samples, and (5) prolonged frozen storage on the integrity of circulating DNA in plasma collected from healthy volunteers.

Conclusion

The integrity (yield and DNA size) of circulating DNA was impacted by clotting (serum versus plasma), sample storage at room temperature or 4 degrees C for 6 h or more, and repeated freeze/thaw cycling of plasma but not DNA samples. The authors recommend processing blood samples within 6 h, aliquoting samples, and extracting DNA prior to long term frozen storage.

Studies (5)

Purpose

To determine if clotting (serum vs plasma) affects the integrity of circulating DNA.

Summary of Findings

Fresh serum samples had a significantly greater DNA yield (leptin gene) compared to plasma samples. Further, the ratio of amplicons of differing size (201 bp/ 105 bp) was greater in serum samples, indicating an increase in the size of circulating DNA.

  • Biospecimens

    FluidPlasma
    FluidSerum
  • Preservation Types

    None (Fresh)
  • Diagnoses

    Normal
  • Platforms

    DNAReal-time qPCR
  • Pre-analytical Factors

    ClassificationPre-Analytical FactorValue(s)
    Biospecimen Aliquots and ComponentsBlood and blood products
    Plasma
    Serum
    Real-time qPCR SpecificLength of gene fragment
    105 bp
    201 bp