Skip to main content

Effects of Prolonged Storage of Whole Plasma or Isolated Plasma DNA on the Results of Circulating DNA Quantification Assays

Sozzi G, Roz L, Conte D, Mariani L, Andriani F, Verderio P, Pastorino U

Publication: J Nat Cancer Inst (2005) • Vol 97 • Page 1848PMID: 16368947View on PubMed

Purpose

To determine the impact of long-term specimen storage (plasma, purified plasma DNA) on DNA quantification by real time quantitative PCR.

Conclusion

DNA content of both plasma aliquots and purified plasma DNA decreased progressively with storage duration, by approximately 30% per year.

Studies (1)

Purpose

To determine the impact of long-term storage of plasma at -80 degrees C and purified plasma DNA at -20 degrees C on DNA quantification of the human telomerase reverse transcriptase (hTERT) gene by real time quantitative PCR.

Summary of Findings

DNA content significantly decreased as a function of storage duration in both plasma aliquots and purified plasma DNA by approximately 30% per year. No significant differences were observed between normal and cancerous specimens.
  • Biospecimens

    FluidPlasma
  • Preservation Types

    Frozen
  • Diagnoses

    NeoplasticCarcinoma
    Normal
  • Platforms

    DNAReal-time qPCR
  • Pre-analytical Factors

    ClassificationPre-Analytical FactorValue(s)
    StorageStorage duration
    4 months
    56 months
    StorageStorage temperature
    -20 degrees C
    -80 degrees C
    Real-time qPCR SpecificTargeted nucleic acid
    hTERT