Tissue microarrays from HOPE-fixed specimens allow for enhanced high through put molecular analyses in paraffin-embedded material.
Goldmann Torsten, Dromann Daniel, Marzouki Marouane, Schimmel Udo, Debel Karsten, Branscheid Detlev, Zeiser Tobias, Rupp Jan, Gerdes Johannes, Zabel Peter, Vollmer Ekkehard
Purpose
Conclusion
Studies (2)
Purpose
The purpose of this study was to determine if HOPE-fixed, paraffin-embedded tissues can be successfully used for tissue microarray detection of breast cancer markers (Ki-67, Her2) and TLR2 in lung.
Summary of Findings
Tissue microarray detection of Ki-67, Her2, and TLR2 using HOPE-fixed paraffin embedded tissues yielded comparable results to those obtained with single tissue sections, and with formalin fixation, with a high degree of staining quality and well preserved morphological detail.
Biospecimens
TissueBreastTissueLungPreservation Types
Other PreservativeFormalinDiagnoses
NeoplasticCarcinomaPlatforms
ProteinTissue microarrayProteinImmunohistochemistryPre-analytical Factors
Classification Pre-Analytical Factor Value(s) Biospecimen Aliquots and Components Type of slide Tissue microarray sectionWhole tissue sectionBiospecimen Preservation Type of fixation/preservation Formalin (buffered)HOPE-Fixation
Purpose
Summary of Findings
Biospecimens
TissueLungPreservation Types
Other PreservativeDiagnoses
NeoplasticPlatforms
RNATissue microarrayRNAIn situ hybridizationPre-analytical Factors
Classification Pre-Analytical Factor Value(s) Biospecimen Preservation Type of fixation/preservation HOPE-Fixation