Fine-needle Aspiration Biopsy of Non-Hodgkin Lymphoma for Use in Expression Microarray Analysis.
Morrison C, Palatini J, Riggenbach J, Radmacher M, Porcu P
Purpose
Comparative analysis of RNA yield and integrity in lymph node fine needle aspirate (FNA) specimens collected in either Trizol or RNAlater with various needle gauges.
Conclusion
Collection of FNA specimens in Trizol, compared to RNAlater, resulted in greater RNA yield and superior quality. Although RNA yield increased with needle gauge in RNAlater specimens, no effect was observed among specimens collected in Trizol. Specimens collected via FNA in Trizol did not differ significantly in terms of gene expression when compared to matched frozen surgical specimens, indicating microarray analysis of FNA specimens is a feasible approach.
Studies (3)
Purpose
To determine if RNA quality and quantity differs among FNA specimens collected in Trizol versus RNAlater.
Summary of Findings
FNA specimen collection in Trizol resulted in a significantly greater RNA yield compared with specimens stored in RNAlater (31.8 vs 4.9 ug, respectively). Further, RNA quality of Trizol collected specimens was superior to those collected in RNAlater, with the majority displaying some evidence of RNA degradation.
Biospecimens
TissueLymph NodePreservation Types
RNAlaterDiagnoses
NeoplasticLymphomaPlatforms
RNASpectrophotometryRNAElectrophoresisPre-analytical Factors
Classification Pre-Analytical Factor Value(s) Biospecimen Preservation RNA stabilization method RNAlaterTrizol reagent
Purpose
Comparative analysis of gene expression, as determined by microarray, among surgically excised specimens and those collected via FNA in Trizol.
Summary of Findings
No significant differences in gene expression were observed among FNA and matched frozen surgical specimens.
Biospecimens
TissueLymph NodePreservation Types
FrozenDiagnoses
NeoplasticPlatforms
RNADNA microarrayPre-analytical Factors
Classification Pre-Analytical Factor Value(s) Biospecimen Acquisition Method of tissue acquisition Fine needle aspirationSurgical resection
Purpose
The purpose of this study was to determine if the gauge of the needle used in FNA impacts RNA yield.
Summary of Findings
The RNA yield of specimens collected in RNAlater increased as a function of needle gauge, although no effect was observed among specimens collected in Trizol.
Biospecimens
TissueLymph NodePreservation Types
RNAlaterDiagnoses
Not specifiedPlatforms
RNASpectrophotometryPre-analytical Factors
Classification Pre-Analytical Factor Value(s) Biospecimen Acquisition Needle gauge 21-gauge22-gauge23-gauge25-gaugeBiospecimen Preservation RNA stabilization method RNAlaterTrizol reagent