Skip to main content

Fine-needle Aspiration Biopsy of Non-Hodgkin Lymphoma for Use in Expression Microarray Analysis.

Morrison C, Palatini J, Riggenbach J, Radmacher M, Porcu P

Publication: Cancer (2006) • Vol 108 • Page 311PMID: 16944538View on PubMed

Purpose

Comparative analysis of RNA yield and integrity in lymph node fine needle aspirate (FNA) specimens collected in either Trizol or RNAlater with various needle gauges.

Conclusion

Collection of FNA specimens in Trizol, compared to RNAlater, resulted in greater RNA yield and superior quality. Although RNA yield increased with needle gauge in RNAlater specimens, no effect was observed among specimens collected in Trizol. Specimens collected via FNA in Trizol did not differ significantly in terms of gene expression when compared to matched frozen surgical specimens, indicating microarray analysis of FNA specimens is a feasible approach.

Studies (3)

Purpose

To determine if RNA quality and quantity differs among FNA specimens collected in Trizol versus RNAlater.

Summary of Findings

FNA specimen collection in Trizol resulted in a significantly greater RNA yield compared with specimens stored in RNAlater (31.8 vs 4.9 ug, respectively). Further, RNA quality of Trizol collected specimens was superior to those collected in RNAlater, with the majority displaying some evidence of RNA degradation.
  • Biospecimens

    TissueLymph Node
  • Preservation Types

    RNAlater
  • Diagnoses

    NeoplasticLymphoma
  • Platforms

    RNASpectrophotometry
    RNAElectrophoresis
  • Pre-analytical Factors

    ClassificationPre-Analytical FactorValue(s)
    Biospecimen PreservationRNA stabilization method
    RNAlater
    Trizol reagent