The effect of fixation and processing on the sensitivity of oestrogen receptor assay by immunohistochemistry in breast carcinoma
Lee H, Douglas-Jones A G, Morgan J M, Jasani B
Purpose
Conclusion
Studies (1)
Purpose
Results of diagnostic testing for ER immunoreactivity were compared among 7 institutions employing biospecimen handling protocols differing in fixative, dehydration and clearing agents, as well as the temperature and duration of the embedding procedure.
Summary of Findings
Biospecimens obtained and differentially processed by 7 institutions did not differ significantly in the proportion of ER diagnostic categories (negative, moderate, strong immunoreactivity), suggesting differences in fixation and processing regimes failed to influence assay sensitivity. ER immunoreactivity was assessed by immunohistochemistry after antigen retrieval with automated equipment.
Biospecimens
TissueBreastPreservation Types
FormalinOther PreservativeDiagnoses
NeoplasticBenignNeoplasticCarcinomaPlatforms
ProteinImmunohistochemistryPre-analytical Factors
Classification Pre-Analytical Factor Value(s) Biospecimen Preservation Clearing agent AlcoholChloroformChloroform/ xyleneIndustrial methylated spiritIsopropanol/ chloroformIsopropyl alcoholXyleneBiospecimen Preservation Embedding duration/condition 180 min240 min285 min300 min360 min56 degrees C60 degrees CFour changes of paraffinThree changes of paraffinTwo changes of paraffinBiospecimen Preservation Type of fixation/preservation 10% acetic formal saline10% formal saline10% neutral buffered formal saline