A comparison of immunohistochemical stain quality in conventional and rapid microwave processed tissues
Emerson LL, Tripp SR, Baird BC, Layfield LJ, Rohr LR
Purpose
Conclusion
Studies (1)
Purpose
The purpose of this study was to assess if microwave-assisted rapid tissue processing (paraffin embedding) adversely impacts immunohistochemical staining of 44 common tumor-associated markers as measured by tissue microarray, immunohistochemistry, and microscopic analysis in the following cancerous and normal tissue types: placenta, prostate, thyroid, tonsil, kidney, breast, cervix, colon, endometrium, stomach. Immunostaining was evaluated using 30 paired specimens by two pathologists that were blind to the tissue processing method applied.
Summary of Findings
Greater than 50% of the original 5,280 microarray tissue punches spotted for microarray analysis were excluded from analysis due to suboptimal staining, technical difficulties in tissue/slide adhesion, and tissue-specific background staining. Of the remaining interpretable tissue pairs, 14.5% differed in the extent of staining and 13.5% displayed differential staining intensity as a result of advanced microwave processing, indicating a high degree of concordance among the two processing regimes.
Biospecimens
TissueProstateTissuePlacentaTissueThyroid GlandTissueTonsilTissueKidneyTissueBreastTissueCervixTissueColorectalTissueEndometriumTissueStomachPreservation Types
FormalinDiagnoses
NeoplasticCarcinomaNormalPlatforms
ProteinTissue microarrayProteinImmunohistochemistryPre-analytical Factors
Classification Pre-Analytical Factor Value(s) Biospecimen Preservation Embedding medium Conventional paraffin embeddingMicrowave-assisted paraffin embedding