Long-term Storage and Recovery of Buccal Cell DNA from Treated Cards
Sigurdson AJ, Ha M, Cosentino M, Franklin T, Haque KA, Qi Y, Glaser C, Reid Y, Vaught JB, Bergen AW
Purpose
Conclusion
Studies (3)
Purpose
DNA yield was assessed using 7 year old saliva coated filter paper cards stored at different temperatures via real time quantitative PCR analysis of the beta-globin gene generating amplicons of increasing length (268, 536, 989 bp).
Summary of Findings
DNA yields were variable across storage conditions and recovery methods. In general the highest gDNA yield was obtained from samples stored at room temperature using DNA recovery method 1 (a single elution in the PCR plate), and the lowest in samples stored at room temperature using DNA recovery method 2 (three elutions using fresh microcentrifuge tubes).
Biospecimens
CellBuccalFluidSalivaPreservation Types
Other PreservativeDiagnoses
Not specifiedPlatforms
DNAReal-time qPCRPre-analytical Factors
Classification Pre-Analytical Factor Value(s) Storage Storage temperature -20 degrees C-80 degrees CRoom temperatureAnalyte Extraction and Purification Analyte isolation method DNA recovery method 1DNA recovery method 2
Purpose
DNA quality was assessed using 7 year old saliva coated filter paper cards stored at different temperatures via real time quantitative PCR analysis of the beta-globin gene generating amplicons of increasing length (268, 536, 989 bp).
Summary of Findings
The lowest incidence of nondetectable DNA (3.4%) occurred in samples stored at room temperature using DNA recovery method 1. PCR amplification of beta-globin was most successful with samples stored at room temperature for all amplicon sizes using DNA recovery method 1. PCR success was inversely proportional to amplicon size.
Biospecimens
CellBuccalFluidSalivaPreservation Types
Other PreservativeDiagnoses
Not specifiedPlatforms
DNAReal-time qPCRPre-analytical Factors
Classification Pre-Analytical Factor Value(s) Storage Storage temperature -20 degrees C-80 degrees CRoom temperatureReal-time qPCR Specific Length of gene fragment 268 bp536 bp989 bp
Purpose
DNA quality was assessed using 7 year old saliva coated filter paper cards stored at different temperatures via multiplex genotyping for short tandem repeats (STR) in the amelogenin locus using DNA recovery methods 1 and 2.
Summary of Findings
Standard tandem repeat genotyping using samples stored at room temperature had the highest success rate, although failure rates were high (>70%). DNA recovery methods 1 and 2 yielded comparable results.
Biospecimens
CellBuccalFluidSalivaPreservation Types
Other PreservativeDiagnoses
Not specifiedPlatforms
DNAReal-time qPCRPre-analytical Factors
Classification Pre-Analytical Factor Value(s) Storage Storage temperature -20 degrees C-80 degrees CRoom temperatureAnalyte Extraction and Purification Analyte isolation method DNA recovery method 1DNA recovery method 2