Skip to main content

Effect of storage time of paraffin sections on the expression of PD-L1 (SP142) in invasive breast cancer.

He J, Wang X, Cai L, Jia Z, Liu Y, Sun X, Wu S, Ding C, Zhang Z, Liu C

Publication: Diagn Pathol (2023) • Vol 18 • Page 131PMID: 38053121View on PubMed

Purpose

This study compared Programmed Cell Death-Ligand 1 (PD-L1) immunohistochemistry (IHC) staining in case-matched breast tumor sections stored unstained for up to 12 weeks at room temperature, 4°C, -20°C or -80°C.

Conclusion

When breast tumor formalin-fixed, paraffin-embedded (FFPE) sections were stained for PD-L1, scores ranged between 1-5 in 43 cases (60.56%), 5-10 in 16 cases (22.54%) and >10 in the remaining 12 cases (16.9%).  PD-L1 positivity (score ≥1) decreased with longer storage durations of unstained sections, regardless of storage temperature. After only 1 week, positivity was 97.18% in sections stored at room temperature or 4°C and 98.59% in sections stored at -20°C or -80°C, but positivity was 54.93% in sections after 12 weeks at room temperature, 43.66% in sections stored at 4°C and 47.89% in specimens stored at -20°C or -80°C. Similarly, PD-L1 Tumor-Infiltrating Immune Cell score (IC) score declined with storage of unstained sections, regardless of storage temperature, declining from 7.84% to 6.62-6.70% after 1 week, 0.85 -1.24% after 12 weeks and 0.42- 0.56% after 24 weeks. Concordance with fresh sections was excellent (Intraclass Correlation Coefficient, ICC ≥ 0.9) when sections were stored at room temperature for ≤ 2 weeks, stored at 4°C or -20°C for ≤ 4 weeks and stored at -80°C for ≤ 3 weeks, good (ICC≥ 0.75) when sections were stored at room temperature or -80°C for 4 weeks or stored at 4°C or -20°C for 8 weeks, moderate (ICC≥ 0.5) when sections were stored at room temperature or -80°C for 8 weeks, and poor (ICC<0.5) at 12 weeks at all storage temperatures evaluated. The authors concluded that PD-L1 staining declines with FFPE section storage; when storage is necessary, unstained FFPE sections should be stored at 4 or -20°C for ≤4 weeks.

Studies (1)

Purpose

This study compared PD-L1 immunohistochemistry (IHC) staining in case-matched breast tumor sections stored unstained for up to 12 weeks at room temperature, 4°C, -20°C or -80°C. This study included 71 PD-L1-positive FFPE breast tumor specimens obtained during radical surgery for invasive breast cancer (67 invasive ductal carcinoma and 4 cases of invasive lobular carcinoma). Details on specimen processing were not provided. Each FFPE specimen was sectioned (details not provided), and unstained serial sections were stored at room temperature, 4°C, -20°C or -80°C for 1, 2, 3, 4, 8, 12, and 24 weeks. Sections were stained by IHC for PD-L1; IHC staining was scored based on the percentage of PD-L1-positively stained immune cells in the tumor area determined independently by two pathologists. A specimen was defined as PD-L1 positive f positive immunostaining was detected in ≥1% of tumor interstitial infiltrating immune cells.

Summary of Findings

When breast tumor formalin-fixed, paraffin-embedded (FFPE) sections were stained for PD-L1, scores ranged between 1-5 in 43 cases (60.56%), 5-10 in 16 cases (22.54%) and >10 in the remaining 12 cases (16.9%).  PD-L1 positivity (score ≥1) decreased with longer storage durations of unstained sections, regardless of storage temperature. After only 1 week, positivity was 97.18% in sections stored at room temperature or 4°C and 98.59% in sections stored at -20°C or -80°C, but positivity was 54.93% in sections after 12 weeks at room temperature, 43.66% in sections stored at 4°C and 47.89% in specimens stored at -20°C or -80°C. Similarly, PD-L1 Tumor-Infiltrating Immune Cell score (IC) score declined with storage of unstained sections, regardless of storage temperature, declining from 7.84% to 6.62-6.70% after 1 week, 0.85 -1.24% after 12 weeks and 0.42- 0.56% after 24 weeks. Concordance with fresh sections was excellent (Intraclass Correlation Coefficient, ICC ≥ 0.9) when sections were stored at room temperature for ≤ 2 weeks, stored at 4°C or -20°C for ≤ 4 weeks and stored at -80°C for ≤ 3 weeks, good (ICC≥ 0.75) when sections were stored at room temperature or -80°C for 4 weeks or stored at 4°C or -20°C for 8 weeks, moderate (ICC≥ 0.5) when sections were stored at room temperature or -80°C for 8 weeks, and poor (ICC<0.5) at 12 weeks at all storage temperatures evaluated. The authors concluded that PD-L1 staining declines with FFPE section storage; when storage is necessary, unstained FFPE sections should be stored at 4 or -20°C for ≤4 weeks.

  • Biospecimens

    TissueBreast
  • Preservation Types

    Formalin
  • Diagnoses

    NeoplasticCarcinoma
  • Platforms

    ProteinImmunohistochemistry
  • Pre-analytical Factors

    ClassificationPre-Analytical FactorValue(s)
    StorageStorage duration
    0 weeks
    1 week
    12 weeks
    2 weeks
    24 weeks
    3 weeks
    4 weeks
    8 weeks
    StorageStorage temperature
    -20°C
    -80°C
    4°C
    Room temperature
    Immunohistochemistry SpecificTargeted peptide/protein
    PD-L1