Skip to main content

Adapting clinical chemistry plasma as a source for liquid biopsies.

Ding SC, Yu J, Liao T, Ahmann L, Yao Y, Ho C, Wang L, Pinsky BA, Gu W

Publication: Elife (2026) • Vol 14PMID: 42065375View on PubMed

Purpose

This paper investigated whether heparin separator tubes are suitable for cell-free DNA (cfDNA)  analysis by comparing yield, fragment size, fragment end motif frequencies, viral loads, copy number alteration (CNA) profiles, estimated tumor fraction, and/or CpG methylation between case-matched plasma from blood collected in heparin separator, EDTA and Streck tubes and processed immediately; between case matched blood collected and stored (up to 24 h at 4°C, room temperature or 37°C) in heparin separator or EDTA tubes; and in case-matched leftover viral positive heparin and EDTA plasma specimens

Conclusion

Fragment size profiles and end motif frequencies were comparable among the heparin, EDTA and Streck plasma that were processed immediately, and methylation levels for CpG sites with ≥30x coverage and cell type proportion estimates were modestly to strongly correlated between the plasma types (ρ≥0.65, all pairs).  The fragment size profiles were comparable between (a) the immediately processed specimen and (b) plasma from blood that was stored for 24 h prior to the first centrifugation in EDTA tubes at room temperature or 4°C and then stored for 7 days at 4°C before the second centrifugation and  (c) plasma from blood stored in heparin tubes at 4°C, and then  stored for 7 days at 4°C before the second centrifugation. However, when blood was stored in heparin tubes at room temperature prior to the first centrifugation, cfDNA fragment size decreased with pre-centrifugation storage duration, indicating degradation. Not surprisingly, DNA became extremely degraded when blood was stored in heparin tubes at 37°C for 24 h between centrifugation steps.

Analysis of case-matched leftover heparin and EDTA plasma, revealed that cfDNA yield (ng/mL plasma) was highly variable and only weakly correlated between case-matched pairs, but  the ratio of read counts aligning to the human genome normalized to the lambda reads was very strongly correlated between EDTA and heparin plasma when lambda phage was spiked in during library preparation (R2=0.998). cfDNA from heparin plasma was more degraded than EDTA plasma, as evidenced by a shift in fragment size distribution and changes in the frequency of four of the six most frequent 4-mer motifs at the 5’ end of the cfDNA fragments. Nevertheless, viral loads, CNA profiles, and estimated tumor fraction were comparable and strongly to very strongly correlated between case-matched EDTA and heparin plasma (ρ=0.95, P<0.001; ρ=0.72-0.96, P<0.001; and ρ=0.77, P<0.001, respectively). When case-matched EDTA and heparin plasma were compared, CpG methylation levels were modestly correlated (ρ=0.63, P<0.001), and cell type proportion estimates were comparable.

Studies (3)

Purpose

This study compared fragment size, fragment end motif frequencies, CpG methylation and estimated cell proportions between case-matched plasma from blood collected in heparin separator, EDTA and Streck tubes. Blood was collected from 5 healthy volunteers during a single venipuncture into heparin separator, EDTA and Streck tubes (further tube details not provided). Plasma was separated by centrifugation at 1,600×g for 10 min followed by 16,000×g for 10 min. Plasma aliquots were then stored at -80°C. cfDNA was extracted using the Maxwell RSC ccfDNA Plasma Kit on a Maxwell RSC 48 instrument. Sequencing libraries were constructed using the NEBNext Ultra II DNA Library Prep Kit, and sequenced on a NovaSeq X platform; fragment size distributions were calculated based on the frequency of fragments between 50 and 600 bp. Copy number alterations were identified using ichorCNA. DNA was converted using the NEBNext Enzymatic Methyl-seq Conversion Module, and FLEXseq DNA libraries were sequenced using the NovaSeq X platform. Tissue of origin was calculated based on the top 250 unmethylated CpG markers for each cell type.

Summary of Findings

Fragment size profiles and end motif rankings of the 256 possible 4-mers were comparable among plasma isolated from K2EDTA, Streck, and heparin separator tubes . Methylation levels for CpG sites with ≥30x coverage and cell type proportion estimates were modestly to strongly correlated between heparin and EDTA (ρ=0.70 and ρ=0.65-0.70, respectively) and heparin and Streck specimens (ρ=0.69, ρ=0.65-0.69, respectively).

  • Biospecimens

    FluidBlood
    FluidPlasma
  • Preservation Types

    Frozen
  • Diagnoses

    Normal
  • Platforms

    DNANext generation sequencing
    DNABisulfite conversion assay
  • Pre-analytical Factors

    ClassificationPre-Analytical FactorValue(s)
    Biospecimen AcquisitionType of collection container/solution
    Heparin separator tube
    K2EDTA tube
    Streck tube