Choice of blood collection methods influences extracellular vesicles counts and miRNA profiling.

Tran V, de Oliveira-Jr GP, Chidester S, Lu S, Pleet ML, Ivanov AR, Tigges J, Yang M, Jacobson S, Gonçalves MCB, Schmaier AA, Jones J, Ghiran IC

Publication: J Extracell Biol (2024) • Vol 3 • Page e70008PMID: 39440167View on PubMed

Purpose

This paper compared the abundance, size, antigenic profile, and miRNA expression among extracellular vesicles (EVs) isolated from EDTA, citrate, and heparin plasma and serum obtained from healthy men and women and examined whether differences were present based on sex, and individual centrifugation steps during EV separation from other particles, and inclusion of an additional freeze-thaw cycle after 3 months of frozen storage. Antigenic profiles of EVs isolated from different Streck cell stabilization tubes (DNA BCT, RNA Complete, and Nucleic Acid) were compared with those from EDTA plasma and serum.

Conclusion

Centrifugation at 12,500 g for 15 min was required for the removal of cells, debris and platelets but did not remove all non-EV light scattering particles; an additional centrifugation at 260,000 g for 24 h did not remove these particles. More EVs were isolated and the mean fluorescent intensity of Acoerela labeling was higher for EVs from serum than citrate, heparin, or EDTA plasma (P<0.01, all). The relative EV diameter range was higher for serum EVs than EDTA plasma EVs (P<0.05). The effects of an additional freeze-thaw cycle on EV surface marker detection were small, with very strong correlations observed between specimens before and after freeze-thaw cycling, regardless of anticoagulant (serum, or EDTA, citrate and heparin plasma) or patient sex. Clustering based on antigenic profile did not separate specimens based on patient sex.  The EVs captured and analyzed by MACSPlex analysis were very similar in plasma among the anticoagulants evaluated, indicating similar surface antigens. Serum had more EVs captured with antibodies against CD2, CD41b, CD41, CD62p, or HLA-ABC and detected with antibodies against CD9 and/or CD63 than plasma, but the significance of the differences was dependent on anticoagulant type.

miRNA expression was highest in EVs from EDTA plasma and lowest in those from heparin plasma, and principal component analysis based on miRNA expression clustered specimens by anticoagulant.  A few miRNAs with higher expression in serum than EDTA plasma were identified (miR-511-5p, miR−381-3p, miR −1-5p, miR −511-3p, miR −4662a-5p, and miR−548j-5p).

EVs isolated from plasma from Streck cell-stabilizing tubes had more platelet-derived EVs than EDTA plasma, with the largest difference relative to EDTA plasma observed with Streck DNA BCT and the smallest difference with Streck Nucleic Acid tubes.

Studies (2)

Purpose

This study compared the abundance, size, antigenic profile, and miRNA expression among extracellular vesicles (EVs) isolated from EDTA, citrate, and heparin plasma and serum obtained from healthy men and women and examined whether differences were present based on sex, and individual centrifugation steps during EV separation from other particles, and inclusion of an additional freeze-thaw cycle after 3 months of frozen storage. Blood was collected from 20 healthy fasting volunteers (15 men and 5 women; 23-52 years of age) using a 21-gauge butterfly needle into K2EDTA, Sodium Citrate (3.2%), PST Gel Lithium Heparin and Serum SST Vacutainer tubes. All tubes were inverted 6-8 times before separation of plasma and serum by centrifugation at 500 g for 10 min at room temperature; cellular material was then removed by centrifugation at 2,500 g for 5 min followed by 12,500 g for 15 min at room temperature. To test if further centrifugation could reduce lipoprotein contamination, an additional centrifugation at 260,000 g for 24 h was performed for some specimens. To investigate the effects of freeze-thaw cycling and frozen storage, specimens were analyzed before and after frozen storage at -20°C for 3 months. RNA was isolated using the miRNeasy Serum/Plasma Advanced Kit and reverse transcribed using the TaqMan microRNA reverse transcription Kit. Levels of 28 miRNAs were quantified in triplicate using real-time PCR using TaqMan-advanced miRNA assays and normalized to miR-4433b-3p. EVs were isolated from the plasma/serum of four volunteers by centrifugation at 2500 g for 10 min and then 12,000 g for 20 min followed by size exclusion chromatography with qEV original 35 nm EV isolation columns. EVs were stained with Acoerela 490 dye and characterized by flow cytometry using a CytoFLEX S. EVs from the plasma/serum of 6 volunteers were further characterized by MACSPlex Human Exosome Multiplex Assay Kit, which uses 39 fluorescent capture beads with antibodies against CD9, CD63, and CD81. EVs were visualized by dark field microscopy using an Olympus BX62 microscope.

Summary of Findings

The presence of red blood cell ghosts, platelets and cell debris in plasma obtained by centrifugation at 500 g for 10 min followed by 2,500 g for 5 min were visible by dark field microscopy, but these were effectively removed by subsequent centrifugation at 12,500 g for 15 min. While light scattering particles remained after centrifugation at 12,500 g for 15 min, they were also present after an additional centrifugation step at 260,000 g for 24 h. The authors postulated that these light scattering particles are likely low-density lipoprotein complexes, as the Acoerela-labelled EVs were pelleted by the ultra high-speed centrifugation step. More EVs were isolated from serum (6.74 × 105 events/uL) than citrate (1.25 × 105 events/uL), heparin (7.88 × 104 events/uL), or EDTA (7.56 × 104 events/uL) plasma (P<0.01, all). The relative EV diameter range was higher for EVs from serum (80.8–210.2 nm) than those from citrate (155.4–171.9 nm), heparin (149.8–164.6 nm), or EDTA (161.1–181.3 nm) plasma, but only the difference between serum and EDTA EVs was significant (P<0.05). The mean fluorescent intensity of Acoerela labeling was also higher for EVs from serum than plasma. The effects of freeze-thaw cycling on EV surface marker detection were small. Overall, antigenic expression levels were very strongly correlated (r=0.9461-0.9962) in specimens before and after an additional freeze-thaw cycle, regardless of anticoagulant (serum and EDTA, citrate and heparin plasma) or patient sex; however, small changes in CD63/CD3 detection were observed regardless of patient gender, and changes in CD9/ROR1 detection were observed in specimens from females. Clustering based on antigenic profile did not separate specimens based on patient sex.

EVs captured and characterized by MACSPlex analysis were very similar among plasma obtained with different anticoagulants, indicating similar surface antigens. Serum had more EVs captured with antibodies against CD2, CD41b, CD41, CD62p, or HLA-ABC and detected with antibodies against CD9 and/or CD63 than plasma, but the significance of the differences was dependent on anticoagulant type; the authors noted that the detection antibody signal was not evenly distributed, indicating at that not all  epitopes on EVs were detected.

miRNA expression was highest in EVs from EDTA plasma and lowest in those from heparin plasma; principal component analysis based on miRNA expression clustered specimens by anticoagulant.  A few miRNAs that had higher expression in serum than EDTA plasma were identified (miR-511-5p, miR−381-3p, miR −1-5p, miR −511-3p, miR −4662a-5p, and miR−548j-5p).

  • Biospecimens

    FluidBlood
    FluidPlasma
    FluidSerum
  • Preservation Types

    Frozen
  • Diagnoses

    Normal
  • Platforms

    RNAReal-time qRT-PCR
    RNALow density array
    ProteinFlow cytometry
    Cell count/volumeLight scattering
  • Pre-analytical Factors

    ClassificationPre-Analytical FactorValue(s)
    PreaquisitionPatient gender
    Female
    Male
    Biospecimen AcquisitionAnticoagulant
    Lithium heparin
    None
    Potassium EDTA
    Sodium citrate
    Biospecimen AcquisitionType of collection container/solution
    K2EDTA Vacutainer
    PST Gel Lithium Heparin tube
    SST Vacutainer tubes
    Sodium Citrate Vacutainer tubes
    Biospecimen Aliquots and ComponentsCentrifugation
    Different number of centrifugation steps compared
    StorageFreeze/thaw cycling
    1 cycle
    2 cycles
    StorageStorage duration
    An additional 3 months frozen storage
    Unspecified