The influence of dead space in blood sampling needle on FVIII level and pharmacokinetic profiles in children with hemophilia.

Zhen Y, Ai D, Huang K, Li G, Chen Z, Wu R

Publication: Hematology (2024) • Vol 29 • Page 2314871PMID: 38346146View on PubMed

Purpose

The purpose of this paper was to investigate the potential impact of dead space from the sampling needle on the quantification of Factor (F)VIII levels and activated partial thromboplastin time (APTT) in specimens collected pre-infusion and post FVIII-infusion from boys with hemophilia.

Conclusion

When blood was collected directly into the first tube, there was dead space from the sampling needle. Significantly longer median APTT and lower FVIII levels were observed in tubes containing dead space than in case-matched properly filled tubes at each timepoint (pre-infusion, and 1, 3, 9, 24 and 48 h post-infusion).  The biases in APTT and FVIII levels observed in tubes containing a dead space were correlated with the levels of APTT and FVIII, respectively, in the properly filled tube. The measured half-life of FVIII was shorter in the tube containing dead space than in properly filled tubes, resulting in a shorter time post-infusion to 5, 2 or 1 IU/dL.

Studies (1)

Purpose

The purpose of this study was to investigate the potential impact of dead space from the sampling needle on the quantification of FVIII levels and APTT in specimens collected pre-infusion and post FVIII-infusion from boys with hemophilia. Blood was collected from nineteen boys (3-14 years of age) with hemophilia before and 1 h, 3 h, 9 h, 24 h and 48 h after infusion of standard half-life FVIII. At each timepoint, two specimens were collected into trisodium citrate tubes. Because the first specimen was collected directly, the space in the needle resulted in “dead space” in the first tube that was not there for the second tube. Immediately after collection, plasma was separated by centrifugation at 2500 g for 15 min at room temperature and stored frozen at -80°C. Factor VIII activity and APTT were quantified using an ACL TOP-700 analyzer.

Summary of Findings

The median APTT was longer in tubes with a dead space than in case-matched properly filled tubes at each timepoint (pre-infusion: 124.3 versus 108.6s, P< 0.0001; 1 h: 40.6 versus 36.6s, P< 0.001; 3 h: 39.0 versus 35.1, P< 0.001; 9 h: 42.5 versus 41.4, P< 0.01; 24 h: 51.9 versus 48.9, P< 0.01; and 48 h: 65.9 versus. 65.8, P< 0.01). Correspondingly, the median FVIII levels were lower in plasma from tubes with a dead space than case-matched properly filled tubes at each timepoint (pre-infusion: 0.5 versus 0.6 IU/dL; P< 0.01, at 1 h: 96.5 versus 102.4 IU/dL, P< 0.01; at 3 h: 78.2 versus 87.2 IU/dL, P< 0.0001; at 9 h: 49.2 versus 51.3 IU/dL, P< 0.001; at 24 h: 14.7 versus 20.1 IU/dL, P< 0.001; and at 48 h: 4.2 versus 4.7 IU/dL, P< 0.05). The biases in APTT and FVIII levels observed in tubes containing a dead space were correlated with the level of APTT and FVIII, respectively, in the properly filled tube (r=0.44, P<0.0001 and r=0.68, P<0.0001, respectively), but the percentage of bias in APTT was not correlated with APTT in the properly filled tube. The measured half-life of FVIII post-infusion was shorter in the tubes containing dead space than the properly filled tubes (9.0 versus 9.75 h, P<0.001), resulting in a shorter time to 5, 2 or 1 IU/dL (41.13 versus 43.38 h, P<0.0001; 55.13 versus 59.0 h, P<0.001; and 68.88 versus 74.63 h, P<0.0001).

  • Biospecimens

    FluidBlood
    FluidPlasma
  • Preservation Types

    Frozen
  • Diagnoses

    Hemophilia
  • Platforms

    MorphologyHematology/ auto analyzer
    ProteinHematology/ auto analyzer
  • Pre-analytical Factors

    ClassificationPre-Analytical FactorValue(s)
    Biospecimen AcquisitionMethod of fluid acquisition
    Improperly filled tube
    Properly filled tube
    Biospecimen AcquisitionTime of biospecimen collection
    1 h post-infusion
    24 h post-infusion
    3 h post-infusion
    48 h post-infusion
    9 h post-infusion
    Pre-infusion
    Biospecimen Aliquots and ComponentsAliquot size/volume
    Properly filled tube
    Tube partially filled due to needle dead space