Skip to main content

Comparison of blood collection tubes for 29 biochemical analytes in pediatric patients with central venous catheters.

Kang H, Cho HW, Rim JH, Hahn SM, Han JW, Lee SG, Lyu CJ, Lim JB

Publication: Clin Biochem (2022) • Vol 107 • Page 73-79PMID: 35545160View on PubMed

Purpose

This paper compared levels of 29 clinical chemistry analytes in paired serum and lithium heparin plasma specimens from pediatric oncology patients.

Conclusion

Lithium heparin plasma had clinically higher levels (bias exceeded the total allowable error) of total protein and albumin and lower levels of sodium and potassium than serum specimens. Passing and Bablok regression analysis showed that bias in all total protein, albumin, sodium, and potassium levels were constant and not proportional.  The bias in all other analytes evaluated was less than the total allowable error.

Studies (1)

Purpose

This study compared levels of 29 clinical chemistry analytes in paired serum and lithium heparin plasma specimens from pediatric oncology patients.  Blood was collected from 52 (25 male and 27 female) pediatric oncology patients (43 patients were < 17 years of age and nine were 18-41 years of age) diagnosed with acute leukemia (19 patients), neuroblastoma (7 patients), medulloblastoma (5 patients), retinoblastoma (five patients), rhabdomyosarcoma (5 patients), Ewing’s sarcoma (3 patients), Wilms’ tumor (2 patients), or other diagnosis (6 patients). After discarding the first 5-8 mL of heparin locked blood, blood was collected via chemoports or Hickman catheters into matched SST and lithium heparin gel tubes.  Serum tubes were allowed to clot for 20 min before separation of serum. Serum and plasma were separated by centrifugation at 2,456 × g for 10 min at 25°C. Levels of calcium, inorganic phosphate, glucose, blood urea nitrogen (BUN), creatinine, uric acid, cholesterol, total protein, albumin, alkaline phosphatase, aspartate transaminase (AST), alanine transaminase (ALT), total bilirubin, direct bilirubin, gamma-glutamyl transferase (GGT), lactate dehydrogenase, creatine kinase  triglycerides, high-density lipoprotein (HDL) cholesterol, low-density lipoprotein (LDL) cholesterol, sodium, potassium, chloride, total carbon dioxide, iron, amylase, lipase, and C-reactive protein (CRP) were quantified in serum and plasma using a Cobas c702 instrument. Clinical significance was defined as a change greater than the smallest total allowable error specified in the desirable biological variation database or the Clinical Laboratory Improvement Amendments.

Summary of Findings

Lithium heparin plasma had slightly higher levels of calcium (+0.8%), glucose (+0.9%), creatinine (+1.0%), total protein (+3.8%), alanine transaminase (+0.1%), direct bilirubin (+0.5%), glutamyl transferase (+0.6%), chloride (+0.2%), tCO2 (+1.5%), magnesium (+1.0%), amylase (+0.3%), and lipase (+0.3%) and lower levels of inorganic phosphate (-1.59%), blood urea nitrogen (- 0.3%), cholesterol (-1.2%), albumin (- 3.0%), alkaline phosphatase (- 1.8%), aspartate transaminase (-0.6%), total bilirubin (- 1.0%), lactate dehydrogenase (-0.1%), creatinine kinase (-1.1%), triglycerides (-0.1%), high-density lipoprotein cholesterol  (-1.7%), low-density lipoprotein cholesterol (-0.9%), sodium (- 0.3%), iron (-1.7%), C-reactive protein (-4.8%), and potassium (-5.3%) than matched serum specimens . However, only differences in total protein, albumin, sodium, and potassium exceeded the desirable bias limit.  Passing and Bablok regression analysis revealed that bias in all total protein, albumin, sodium, and potassium were constant and not proportional.

  • Biospecimens

    FluidBlood
    FluidPlasma
    FluidSerum
  • Preservation Types

    None (Fresh)
  • Diagnoses

    NeoplasticPediatric
    NeoplasticSarcoma
    NeoplasticLeukemia
  • Platforms

    CarbohydrateClinical chemistry/auto analyzer
    Electrolyte/MetalClinical chemistry/auto analyzer
    GasClinical chemistry/auto analyzer
    LipidClinical chemistry/auto analyzer
    LipoproteinClinical chemistry/auto analyzer
    ProteinClinical chemistry/auto analyzer
    PeptideClinical chemistry/auto analyzer
    Small moleculeClinical chemistry/auto analyzer
    SteroidClinical chemistry/auto analyzer
  • Pre-analytical Factors

    ClassificationPre-Analytical FactorValue(s)
    Biospecimen AcquisitionType of collection container/solution
    Lithium heparin tube
    SST
    Biospecimen Aliquots and ComponentsBlood and blood products
    Plasma
    Serum