This paper compared levels of 25 biochemistry analytes and hemolysis indices in paired blood specimens transported by pneumatic tube system (PTS) with those that were hand-delivered; comparisons were drawn both before and after corrective action to reduce hemolysis during transport in the PTS system.
Impact of Pneumatic Transport System on Preanalytical Phase Affecting Clinical Biochemistry Results.
Kumari S, Kumar S, Bharti N, Shekhar R
Purpose
Conclusion
In the initial analysis, a total of 9% of PTS transported samples and 2.5% of hand-delivered specimens were classified as hemolyzed (>0.3 g/L of hemoglobin), and levels of potassium, lactate dehydrogenase (LDH), aspartate aminotransferase (AST), and phosphorus were higher and levels of bilirubin and direct bilirubin were lower in specimens transported by PTS compared to matched hand-delivered specimens. However, only increases in LDH and potassium were considered clinically significant. After corrective action (additional cushioning, lowering the blower speed, and reducing transport distance), levels of sodium, potassium, and AST were still significantly higher in the PTS transported specimens compared to hand-delivered specimens, but the differences were smaller and no longer clinically significant. Further, only 2.5% PTS transported and 2% of hand-delivered samples were hemolyzed after corrective action.
Studies (1)
Purpose
This study compared levels of 25 biochemistry analytes and hemolysis indices in paired blood specimens transported by pneumatic tube system (PTS) with those that were hand-delivered; comparisons were drawn both before and after corrective action to reduce hemolysis during transport in the PTS system. Blood was collected from 100 healthy volunteers (age 18-60 years) into two clot activator and two potassium fluoride tubes using a 21-gauge needle before and after alteration of the PTS system. PTS system alterations included adding cushioning in the carrier and below the station, reprogramming to the shortest possible path, and decreasing the blower pressure applied to the carrier from ±160 mbar to ±105 mbar, resulting in an increase in transit time from 61 (±10) seconds to 106 (±7) seconds. One tube of each type was transported by PTS while the other was hand-delivered. After arrival, tubes were placed in an ATRAS machine for sorting, and analytes were quantified using Beckman Coulter AU 5800 and DxC 700 AU analyzers. Specimens with >0.3 g/L of hemoglobin were considered hemolyzed. Clinical significance was set at a change > 10% or changes of ≥0.075 mmol/L for calcium, ≥3.0 mmol/L for sodium, and ≥0.3 mmol/L for potassium.
Summary of Findings
In the initial analysis, a total of 9% of PTS transported samples and 2.5% of hand-delivered specimens were classified as hemolyzed (>0.3 g/L of hemoglobin). Levels of potassium, LDH, AST, and phosphorus were higher in specimens transported by PTS compared to matched hand-delivered specimens (p=0.000, p=0.001, p=0.025, and p=0.047, respectively), and levels of bilirubin and direct bilirubin were lower in PTS transported specimens (p=0.032 and p=0.47, respectively). The increases in LDH and potassium were considered clinically significant (>10%), and, according to the authors, were likely the result of hemolysis. Levels of sodium, potassium, and AST were still significantly higher in PTS transported after corrective action than hand-delivered specimens (p=0.045, p=0.012, and p=0.042, respectively), but the differences were smaller and no longer clinically significant. Further, only 2.5% of PTS transported and 2% of hand-delivered samples were hemolyzed after corrective action. Levels of calcium, chloride, creatinine, high-density lipoprotein, sodium, urea, alanine aminotransferase, albumin, alkaline phosphatase, amylase, glucose, iron, low-density lipoproteins, magnesium, protein, total cholesterol, triglycerides, and uric acid were unaffected by PTS transport.
Biospecimens
FluidBloodPreservation Types
None (Fresh)Diagnoses
Not specifiedPlatforms
CarbohydrateClinical chemistry/auto analyzerElectrolyte/MetalClinical chemistry/auto analyzerLipidClinical chemistry/auto analyzerProteinClinical chemistry/auto analyzerSmall moleculeClinical chemistry/auto analyzerSteroidClinical chemistry/auto analyzerPre-analytical Factors
Classification Pre-Analytical Factor Value(s) Storage Specimen transport duration/condition After corrective action (additional cushioning, lowering blower speed, and reducing transport distance)Pre-corrective action to PTS systemStorage Within hospital transportation method Hand-deliveredPneumatic tube system