Skip to main content

Comparison of single and double centrifugation methods for preparation of Platelet-Rich Plasma (PRP).

Saqlain N, Mazher N, Fateen T, Siddique A

Publication: Pak J Med Sci (2023) • Vol 39 • Page 634-637PMID: 37250535View on PubMed

Purpose

This paper compared platelet, red blood cell (RBC), and white blood cell counts (WBC) in plasma obtained by a single centrifugation step at 3500 x g and plasma obtained by centrifugation at 1000 x g followed by 800 x g.

Conclusion

Platelet counts and the percentage of platelets retained in the plasma (platelet yield) were higher in plasma obtained by double centrifugation (1000 x g for 5 min followed by 800 x g for 10 min) than by single centrifugation (3500 x g for 10 min). However, WBC counts were higher in single-spin plasma than in double-spin plasma, but there was no difference in RBC counts.

Studies (1)

Purpose

This study compared platelet, RBC, and WBC counts in plasma obtained by a single centrifugation step at 3500 x g and plasma obtained by centrifugation at 1000 x g followed by 800 x g. Blood was collected from fifty volunteers (age: 20-45 years) into tri-sodium citrate syringes and transferred to tubes. Plasma was separated from matched tubes by single centrifugation at 3500 x g for 10 min, and by double centrifugation at 1000 x g for 5 min followed by centrifugation at 800 x g for 10 min. Platelet and cell counts were enumerated in whole blood and plasma using a SYSMEX hematology analyzer.

Summary of Findings

Platelet counts and the percentage of platelets retained in the plasma (platelet yield) were higher in plasma obtained by double centrifugation (1000 x g for 5 min followed by 800 x g for 10 min) than by single centrifugation (3500 x g for 10 min) (P<0.01, both). However, WBC counts were higher in single-spin plasma than double-spin plasma (6.05 x 103 versus 1.06 x 103 per µL, P<0.01), but there was no difference in RBC counts.

  • Biospecimens

    FluidBlood
    FluidPlasma
  • Preservation Types

    None (Fresh)
  • Diagnoses

    Normal
    Not specified
  • Platforms

    Cell count/volumeHematology/ auto analyzer
  • Pre-analytical Factors

    ClassificationPre-Analytical FactorValue(s)
    Biospecimen Aliquots and ComponentsCentrifugation
    Different number of centrifugation steps compared
    Multiple speeds compared