The purpose of this paper was to compare tumor content (quantified as area and percentage) in formalin-fixed paraffin-embedded (FFPE) colorectal tumor sections immediately after collection (using captured whole slide images) and after > 4 years of storage as stained FFPE sections or blocks.
Accuracy of whole slide image based image analysis is adversely affected by preanalytical factors such as stained tissue slide and paraffin block age.
Shaker N, Sardana R, Hamasaki S, Nohle DG, Ayers LW, Parwani AV
Purpose
Conclusion
Rescanned slides had lower tumor area and tumor percentage than the original image; the magnitude of the difference in tumor content between timepoints was smaller for FFPE colorectal tumor specimens that were collected and sectioned in 2014 than in 2012. Fresh sections of stored FFPE blocks generally had a smaller tissue area than image of the section cut and evaluated at the time of collection. Fresh cut FFPE sections had a high incidence of “chatter” folds and/or wrinkles (present in 45% of sections), and holes (holes). Fresh- cut sections also had a smaller tumor area, although many had a higher percentage of tumor content. Importantly, the increase in tumor percentage was observed regardless of collection year or the presence of chatter or holes.
Studies (1)
Purpose
The purpose of this study was to compare tumor content (quantified as area and percentage) in whole slide images of FFPE colorectal tumor sections obtained immediately after collection and after > 4 years storage as stained FFPE sections or blocks. A total of 31 FFPE colorectal cancer specimens that had been fixed, H&E stained, and scanned within one month of collection were included in the study. Specimens were collected and originally imaged between 2012-2014 (73 images). For this study, either new sections were cut from the stored FFPE blocks, H&E stained, and scanned (69 images) or the original slides were rescanned (76 images) during or after 2018 (≥4 years). Tissue and tumor area were delineated using a morphometric algorithm based on whole slide images of adenocarcinoma. The significance of the changes observed was not evaluated.
Summary of Findings
Rescanned slides had lower tumor area and tumor percentage than the original image; the magnitude of the difference in tumor content between timepoints was smaller for FFPE colorectal tumor specimens that were collected and sectioned in 2014 than in 2012. Fresh sections of stored FFPE blocks generally had a smaller tissue area than image of the section cut and evaluated at the time of collection. Fresh cut FFPE sections had a high incidence of “chatter” folds and/or wrinkles (present in 45% of sections), and holes (holes). Fresh- cut sections also had a smaller tumor area, although many had a higher percentage of tumor content. Importantly, the increase in tumor percentage was observed regardless of collection year or the presence of chatter or holes.