Obtaining miRNA from Saliva-Comparison of Sampling and Purification Methods.

Urbizu A, Arnaldo L, Beyer K

Publication: Int J Mol Sci (2023) • Vol 24PMID: 36768706View on PubMed

Purpose

This paper compared RNA yield, DNA contamination, and levels of seven microRNA (miRNA, miR) among case-matched saliva specimens collected in three different containers (Oragene, Salimetrics, and a 50 mL tube) that was isolated by three different methods (miRNeasy, miRVana and NucleoSpin).

Conclusion

Collection of saliva in Oragene tubes resulted in the highest RNA yields and highest levels of four of the seven miRNAs quantified, but slightly lower recovery of two of the extraction spike-in controls. Generally, the highest RNA yields were obtained when extraction was with mirVana Kit, but the percentage of specimens with acceptable purity (a ratio of absorbance at 260 to 280 nm that was between 1.8-2.1) was lower than when the miRNeasy Kit was used. Notably, both the miRVana and NucleoSpin Kits required an additional DNase step to completely eliminate DNA contamination. Except for miR-375-3p, significantly higher levels of each targeted miRNA were obtained when extraction was with miRNeasy Kit as opposed to miRVana or Nucleospin Kits. The authors report no differences in the levels of the investigated miRNAs among specimens collected from males and females volunteers. The authors shared that three of the five participants had difficulty collecting saliva using the Salimetrics collector, and that the Oragene tube required an additional 1-2 h of incubation time.

Studies (1)

Purpose

This study compared RNA yield, DNA contamination, and levels of seven miRNAs among case-matched saliva specimens collected in three difference containers (Oragene, Salimetrics and 50 mL tube) using RNA isolated using three different extraction kits (miRNeasy, miRVana, and NucleoSpin Kits). Saliva was collected by passive drooling between 8-10 AM from five volunteers (three females and two males) on three days into Oragene RNA collection tubes, Salimetrics 2 mL cryovials and 50 mL sterile conical tubes. Immediately after collection, Oragene containers were thoroughly mixed and stored at room temperature while Salimetrics tubes and 50 mL tubes were immediately stored at -80°C. RNA was extracted from saliva spiked with UniSp2, UniSp4, and UniSp5 using the mirVana miRNA Isolation Kit, the NucleoSpin miRNA Plasma Kit and the miRNeasy Serum/Plasma Advanced Kit. RNA concentration and purity were quantified by spectrophotometer. DNA contamination was evaluated by PCR amplification of the synuclein gene (SNCA) and a fragment of noncoding mitochondrial DNA. DNA was removed from specimens with DNA contamination with the DNA-free DNA Removal Kit and verified by PCR. RNA was spiked with UniSp6 prior to reverse transcription with the miRCURY LNA RT Kit. Levels of spike-in controls and 7 miRNAs were quantified by real-time PCR using the miRCURY LNA SYBR Green PCR Kit, which contains UniSp3.

Summary of Findings

RNA yields were higher when saliva was collected in Oragene tubes compared to specimens collected in 50 mL conical or Salimetrics tubes (10.1 µg versus 4.31 or 2.05 µg, respectively, P < 0.002); and, this difference was particularly pronounced when extraction was with the NucleoSpin or miRNeasy Kits. While ANOVA analysis did not identify an effect of RNA extraction method on RNA yield,  the Wilcoxon Signed-Rank Test revealed that total RNA yield was higher when RNA was extracted from saliva in 50 mL conical tubes using the mirVana versus the NucleoSpin Kit (P=0.0317) or the miRNeasy Kit (P=0.0317), and RNA yields were higher in saliva in Salimetrics tubes when extraction was with the mirVana Kit compared to the NucleoSpin Kit (P=0.0317). Extraction efficiency (yield/saliva volume) was significantly higher when RNA was extracted from saliva in Salimetrics or 50 mL conical tubes with the mirVana Kit compared to extraction with the NucleoSpin Kit (P<0.05), and from saliva in 50 mL conical tubes when extraction was with the mirVana Kit compared to the miRNeasy Kit. The percentage of specimens with acceptable purity (a ratio of absorbance at 260 to 280 nm that was between 1.8-2.1) was highest when extraction was with miRNeasy Kit. The miRNeasy Kit also effectively removed all detectable DNA contamination; but when extraction was with the Norgen or miRVana Kit, an additional DNase step was required to completely eliminate DNA contamination. Recovery of the extraction spike in controls UniSp2, UniSp4, and UniSp5 were all highest when extraction was with the miRNeasy Kit, and recovery of UniSp2 and UniSp4 were higher when saliva was collected in Salimetrics tubes rather than Oragene or 50 mL conical tubes.  Levels of the spike-in controls UniSp3 (PCR control) and UniSp6 (added before reverse transcription) were comparable among the collection tubes and extraction methods evaluated. ANOVA identified a significant effect of saliva collection device on levels of miR-30c-5 (P < 0.0001), miR-191-5p (P < 0.0001), miR223-3p (P < 0.0001), has-miR-24-3p (P < 0.0001), miR-27a-3p (P < 0.02), and miR-375- 3p (P < 0.02); significantly higher levels of miR-223-3p,miR-24-3p, miR-191-5p, and miR-30c-5p were observed when Oragene tubes were used for saliva collection compared to when Salimetrics or 50 mL conical tubes were used. ANOVA analysis also identified a significant effect of RNA extraction method on levels of all seven miRNAs investigated (P ≤ 0.0004, all). With the exception of miR-375-3p, significantly higher levels of each of the miRNAs investigated was obtained when extraction was with the miRNeasy Kit as opposed to either the miRVana or NucleoSpin Kits (P<0.005 all). Higher levels of hsa-miR-24-3p and hsa-miR-27a-3p were obtained following extraction with the miRVana Kit than the NucleoSpin Kit (P = 0.0023 and P < 0.001, respectively). The authors report no differences in the levels of the investigated miRNAs between saliva specimens collected from males and females. The authors shared that three of the five participants had difficulty collecting saliva using the Salimetrics collector, and that the Oragene tube was the most expensive collection option evaluated and required an additional 1-2 h of incubation time.

  • Biospecimens

    FluidSaliva
  • Preservation Types

    FrozenOCT
  • Diagnoses

    Not specified
  • Platforms

    RNAReal-time qRT-PCR
    RNASpectrophotometry
    DNAPCR
    DNAElectrophoresis
  • Pre-analytical Factors

    ClassificationPre-Analytical FactorValue(s)
    PreaquisitionPatient gender
    Female
    Male
    Biospecimen AcquisitionType of collection container/solution
    50 mL sterile conical tubes
    Oragene RNA collection tubes
    Salimetrics 2 mL cryovials
    Analyte Extraction and PurificationAnalyte isolation method
    NucleoSpin
    miRNeasy
    miRVana
    mirVana
    Analyte Extraction and PurificationNucleic acid digestion
    Extra DNAse step
    One DNase step
    Real-time qRT-PCR SpecificTargeted nucleic acid
    miR-191-5p
    miR-223-3p
    miR-24-3p
    miR-26b-5p
    miR-27a-3p
    miR-30c-5p
    miR-375-3p