Capillary blood sampling increases the risk of preanalytical errors in pediatric hospital care: Observational clinical study.

Hjelmgren H, Nilsson A, Myrberg IH, Andersson N, Ygge BM, Nordlund B

Publication: J Spec Pediatr Nurs (2021) • Vol 26 • Page e12337PMID: 33960595View on PubMed

Purpose

The purpose of this paper was to retrospectively identify factors that increase the risk of preanalytical errors in blood specimens from pediatric patients. In particular, the influence of sample type (venous versus capillary specimens), patient weight (<10 kg than ≥11 kg), patient age, patient gender, number of specimens collected, hospital ward of collection, and academic degree of the nurse performing the blood collection were investigated.

Conclusion

Preanalytical errors that included clotting, hemolysis, improper tube filling, sample mixing and wrong blood specimen type were observed in 128 of the 951 specimens examined. Overall, the most common preanalytical error was clotting which was present in 38% of specimens with a preanalytical error (49 of 128 specimens). Clotting was responsible for a larger percentage of errors in capillary than venous specimens (33% versus 5.5%, P<0.001) but rates of other preanalytical errors were comparable between the specimen types examined.  The percentage of specimens with a preanalytical error was higher for capillary than venous blood specimens, for specimens from patients <10 kg than ≥11 kg, for specimens collected from toddlers (1-2 years) and neonates (0-2 months) than adolescents (10-18 years) and when two or more tubes were collected rather than one tube. There was no difference in the percentage of specimens with a preanalytical error when specimens collected from the following patient groups were compared: males and females; adolescents and children (6-9 years), preschoolers (3-5 years,) and infants (3-11 months); specimens collected at two different wards; the academic degree of the attending nurse. Further analysis found that the risk of preanalytical errors was associated with a patient weight of <10 kg when all specimens (capillary and venous specimens) were considered, but not when only capillary blood was examined.  

Studies (1)

Purpose

The purpose of this study was to retrospectively identify factors that increase the risk of a preanalytical error in blood specimens collected from pediatric patients. In particular, the influence of sample type (venous versus capillary specimens), patient weight (<10 kg than ≥11 kg), patient age, patient gender, number of specimens collected, hospital ward of collection, and academic degree of the nurse performing the blood collection were investigated. Records from 951 blood specimens (354 capillary and 597 venous) collected at two hospital wards from 645 patients, which included 128 specimens with an identified preanalytical error, were included. Capillary blood was collected by nurse assistants into Microtainers and venous blood was collected by nurses into Microtainer (0.5 mL) or vacuum tubes (4 mL). For all specimens, the following details were documented: sampling method (capillary versus venous collection), the nurses’s academic degree, anatomical location of the blood draw, needle size, the number of punctures, as well as each patient’s gender, age, weight and diagnosis.

Summary of Findings

As expected, when only one specimen was collected it was more likely to be a capillary than a venous specimen, but when three or more specimens were needed venous blood was more likely to be collected.  Capillary blood specimens were also more likely to be collected than venous blood in patients with a fever or respiratory symptoms, but less likely in patients diagnosed with cancer. The preanalytical errors documented included clotting, hemolysis, improper tube filling, sample mixing, and wrong blood specimen type; one or more preanalytical error was observed in 128 of the 951 blood specimens evaluated. Overall, the most common preanalytical error was clotting, which was present in 38% (49 of 128 specimens) of specimens with a documented preanalytical error. While clotting was responsible for a larger percentage of preanalytical errors in capillary compared to venous specimens (33% versus 5.5%, P<0.001), preanalytical error rates due to the remaining errors did not differ significantly between specimen types.  The percentage of specimens with a preanalytical error was higher for capillary than venous blood specimens (20% versus 9.4%, P<0.001), for specimens from patients weighing <10 kg than ≥11 kg (20% versus 11%, P<0.001), for specimens collected from toddlers (1-2 years) and neonates (0-2 months) than adolescents (10-18 years) (16% and 22%, respectively versus 9.1%, P=0.021 and P=0.002, respectively), and when two or more tubes were collected rather than one tube (16% versus 8.9%, P=0.002). However, the percentage of specimens with a preanalytical error did not differ when the following groups were compared: males and females; specimens from adolescents and children (6-9 years), preschoolers (3-5 years) and infants (3-11 months); specimens collected at two different wards; and when blood specimens were collected by a nurse with or without an academic degree. Further analysis found that the risk of a preanalytical error was associated with a patient’s weight, specifically a weight <10 kg carried a higher risk when all specimens (capillary and venous specimens) were considered, but not when capillary blood was examined separately.  

  • Biospecimens

    FluidBlood
  • Preservation Types

    None (Fresh)
  • Diagnoses

    Not specified
  • Platforms

    Cell count/volumeMacroscopic observation
    MorphologyHematology/ auto analyzer
    ProteinHematology/ auto analyzer
  • Pre-analytical Factors

    ClassificationPre-Analytical FactorValue(s)
    PreaquisitionPatient age
    Adolescents (10-18 years)
    Children (6-9 years)
    Infants (3-11 months)
    Neonates (0-2 months)
    Preschoolers (3-5 years)
    Toddlers (1-2 years)
    PreaquisitionPatient gender
    Female
    Male
    PreaquisitionPatient weight
    <10 kg
    ≥11 kg
    Biospecimen AcquisitionAnatomical location of blood draw
    Capillary
    Vein
    Biospecimen AcquisitionLocale of biospecimen collection
    Two hospital wards compared
    Biospecimen AcquisitionMethod of fluid acquisition
    Staff group performing phlebotomy compared