The purpose of this paper was to compare cell-free DNA (cfDNA) levels among ear lobe and fingertip blood specimens obtained before, during and after exercise and venous specimens obtained before and after exercise. Potential effects of serial sampling from the ear lobe and fingertip while the patient was at rest and the use of hyperemizing ointment on cfDNA levels in venous specimens were also investigated. Correlations between cfDNA levels and oxygen consumption (VO2), heart rate, lactate level and rate of perceived exhaustion (Borg scores) were also evaluated.
Feasibility of Cell-Free DNA Measurement from the Earlobe during Physiological Exercise Testing.
Haller N, Tomaskovic A, Stöggl T, Simon P, Neuberger E
Purpose
Conclusion
While there were no significant differences in cfDNA concentration between venous fingertip and ear lobe specimens pre-exercise, cfDNA levels increased in both specimen types during exercise, and ear lobe specimens had significantly higher cfDNA levels than fingertip specimens collected 5- and 15-min post-exercise. cfDNA levels in ear lobe specimens were very strongly correlated with cfDNA levels in fingertips specimens, and VO2, heart rate, and Borg scores in fingertip specimens; very strong correlations were also observed between cfDNA levels and VO2 in venous specimens. Strong correlations were observed between cfDNA levels in venous specimens and earlobe and fingertip specimens. While the serial fingertip specimens collected while the patient was at rest remained consistent, cDNA levels appeared to increase in serial ear lobe specimens collected while the patient was at rest, with larger increases noted in both patients when hyperemizing ointment was used.
Studies (1)
Purpose
The purpose of this study was to compare cfDNA levels among ear lobe and fingertip blood specimens obtained before, during and after exercise and venous specimens obtained before and after exercise. Potential effects of serial sampling from the ear lobe and fingertip collected while the patient was at rest and the use of hyperemizing ointment on cfDNA levels in venous specimens were also investigated. Correlations between cfDNA levels and oxygen consumption (VO2), heart rate, lactate level, and rate of perceived exhaustion (Borg scores) were also evaluated. Ear lobe and fingertip blood were collected into Microvette CB 300 K2E tubes and venous blood was collected in K3EDTA S-Monovette tubes prior to (ear lobe, fingertip, and venous specimens), during (ear lobe and fingertip specimens) and post- exercise (ear lobe, fingertip, and venous specimens) from five volunteers (diagnosis not specified) with three patients completing two rounds of exercise testing. Patients exercised for intervals of 3 min followed by a 30-45 sec pause for blood sampling from the fingertip (rotating through finger) and ear lobe (two specimens, one for lactate and followed by one for cfDNA analysis). The initial speed of walking (6 km/h) was increased by 2 km/h after each pause until the patients reached voluntary exhaustion. Additional venous blood was obtained immediately following exercise from the ear lobe and fingertip, as well as 5- and 15-min post-exercise. To investigate repeated sampling effects, blood was collected from two patients nine consecutive times 3 min apart from the fingertip, from the ear lobe without hyperemizing ointment, and from the ear lobe with hyperemizing ointment. Plasma was separated by centrifugation at 1600 x g for 10 min and stored at -20°C. cfDNA was quantified in plasma by real-time PCR amplification of a 90 bp fragment of human long nuclear elements (LINEs). The method for analysis of lactate levels and VO2 was not specified.
Summary of Findings
cfDNA levels were higher in earlobe than fingertip specimens (P<0.001) and increased in both specimen types during exercise (P<0.001). While there were no significant differences in cfDNA concentration between venous, fingertip, and ear lobe specimens pre-exercise, ear lobe specimens had significantly higher cfDNA levels 5- and 15-min post-exercise than fingertip specimens (P<0.05, both). There was a mean log10 difference of 0.09 between ear lobe and fingertip specimens. Analysis of serially collected earlobe and fingertip specimens showed a good and excellent degree of repeatability, respectively, as assessed by intraclass correlation coefficients (ICC=0.85 and ICC=0.93, respectively). Very strong correlations were observed between ear lobe cfDNA levels and fingertip cfDNA levels (r=0.91, P<0.001), VO2 (r=0.92, P<0.001), heart rate (r=0.93, P<0.001) and Borg scores(r=0.93, P<0.001); between fingertip cfDNA levels and heart rate (r=0.90, P<0.001) and Borg scores (r=0.93, P<0.001); and between venous cfDNA levels and VO2 (r=0.91, P<0.001). Strong correlations were observed between cfDNA levels in venous specimens and earlobe (r=0.80, p<0.05) and fingertip specimens (r=0.82, P<0.01) . While serial fingertip specimens taken while the patient was at rest remained consistent, cDNA levels appeared to increase in serial ear lobe specimens collected while the patient was at rest, with larger increases noted in both patients when hyperemizing ointment was used (significance not evaluated due to sample size).
Biospecimens
FluidBloodFluidPlasmaPreservation Types
FrozenDiagnoses
Not specifiedPlatforms
DNAReal-time qPCRSmall moleculeClinical chemistry/auto analyzerPre-analytical Factors
Classification Pre-Analytical Factor Value(s) Preaquisition Anesthesia Hyperemizing ointmentNoneBiospecimen Acquisition Anatomical location of blood draw Ear lobeFingertipVeinBiospecimen Acquisition Time of biospecimen collection 15 min post-exercise5 min post-exerciseDuring exerciseImmediately after exercisePre-exercise