Skip to main content

Optimizing Concentration of Polyethelene Glycol for Exosome Isolation from Plasma for Downstream Application.

Tangwattanachuleeporn M, Muanwien P, Teethaisong Y, Somparn P

Publication: Medicina (Kaunas) (2022) • Vol 58PMID: 36363557View on PubMed

Purpose

This paper compared exosomes isolated from pooled plasma by three different methods (precipitation with 5-20% polyethelene glycol (PEG), the ExoQuick Kit, and Total Exosome Isolation Reagent) with regards to exosome size and yield, protein expression levels, cell-free DNA (cfDNA) levels, and microRNA (miRNA, miR) levels.

Conclusion

The mean size distribution range of isolated exosomes was dependent on the isolation method, which led the authors to conclude that PEG can precipitate smaller EVs. The highest yield of exosomess was obtained when isolation was by precipitation with 10% PEG followed by the Exoquick Kit. Isolation of exosomes using 10%, 15% and 20% PEG or the ExoQuick Kit led to higher protein levels of the exosome markers, CD9, CD63, and ALIX and a higher abundance of cfDNA (170-176 bp) than when exosomes were isolated using the Total Exosome Isolation Reagent or 5% PEG.  cfDNA levels of ALU115 were not significantly different among the exosome isolation methods evaluated.  However, significantly lower quantification cycle (Cq) values were obtained for miR-122 when exosomes were isolated using 10% PEG compared to the ExoQuick Kit or with 5% PEG, while miR-16 Cq values were lower when exosomes were precipitated with 10 or 15% PEG than the Total Exosome Isolation Reagent. SDS-PAGE band intensities were greatest when exosomes were isolated using 20% PEG. However, the most proteins were identified when exosomes were isolated using 15% PEG, and the authors note a higher number of low-density and high-density lipoproteins when isolation was with PEG than the commercial kits evaluated.

Studies (1)

Purpose

This study compared exosomes isolated from pooled plasma by three different methods (precipitation with 5-20% PEG, the ExoQuick Kit, and Total Exosome Isolation Reagent) with regards to exosome size and yield, protein expression levels, cfDNA levels, and miRNA levels. Pooled plasma (from 3 male and 3 female volunteers) was centrifuged at 3000 g for 15 min and treated with thrombin, and then recentrifuged at 10,000 g for 5 min.  DNA and RNA (not encased within an exosome) was removed from platelet poor plasma specimens by incubation with DNase I or RNase A at 37°C for 15 min. Exosomes were isolated by precipitation with 5, 10, 15 or 20% PEG 8000; the Total Exosome Isolation Reagent, or the ExoQuick Kit.  Isolated exosomes were stored at -80°C and were characterized by nanoparticle tracking analysis. cfDNA was isolated from exosomes using the QIAamp Circulating Nucleic Acid Kit and yield and fragment size were evaluated by bioanalyzer and real-time PCR amplification of a 115 bp amplicon of ALU. miRNA was extracted from exosomes using the QIAamp Serum/blood Kit and levels of miR-122 and miR-16 were quantified by real-time PCR.  Levels of CD63, CD9 and TSG101 were analyzed in exosomes by Western Blot. Proteins were separated by SDS-PAGE, excised, trypsin-digested and identified by LC-MS/MS.

Summary of Findings

The mean size distribution range of isolated exosomes was 134 nm when the ExoQuick Kit was used for isolation, 149 nm when the Total Exosome Isolation Reagent was used, and 168, 126, 146 and 134 nm when exosomes were precipitated with 5, 10, 15 and 20% PEG, respectively. The authors interpreted this data as supporting the capability of PEG for precipitating smaller extracellular vesicles The highest yield of exosomes was obtained when isolation was by precipitation with 10% PEG, followed by the Exoquick Kit; exosome yield was lowest when isolation was by precipitation with 5% PEG.  Protein expression of exosome markers (CD9, CD63 and ALIX) were higher in exosomes isolated using 10%, 15% and 20% PEG or using the ExoQuick Kit as opposed to isolation using the Total Exosome Isolation Reagent or 5% PEG.  cfDNA of 170-176 bp was detected in exosomes precipitated with 10, 15 or 20% PEG; and using the ExoQuick Kit, but not among exosomes precipitated with 5% PEG or Total Exosome Isolation Reagent. While ALU115 levels were not significantly different among the exosome isolation methods, levels were non-significantly lower in exosomes when precipitated with 5% PEG.  Significantly lower quantification cycle (Cq) values were obtained for miR-122 when exosomes were isolated using 10% PEG than the ExoQuick Kit or 5% PEG (P<0.05, both) and for miR-16 when exosomes were precipitated with 10 or 15% PEG compared to the Total Exosome Isolation Reagent (P<0.001 and P<0.05, respectively). SDS-PAGE band intensities were greatest when exosomes were isolated using 20% PEG, followed by 15% PEG, 10%PEG, the ExoQuick Kit, and the Total Exosome Isolation Reagent and lowest when exosomes were isolated using 5% PEG. However, 475 proteins were identified when exosomes were isolated using 15% PEG, but only 339-372 proteins were identified in exosomes isolated by all other methods evaluated. The authors noted a higher number of low-density and high-density lipoproteins when exosome isolation was with PEG compared to the commercial kits.

  • Biospecimens

    FluidPlasma
  • Preservation Types

    Frozen
  • Diagnoses

    Normal
  • Platforms

    DNAAutomated electrophoresis/Bioanalyzer
    DNAReal-time qPCR
    RNAReal-time qRT-PCR
    ProteinWestern blot
    ProteinLC-MS or LC-MS/MS
    Cell count/volumeLight scattering
  • Pre-analytical Factors

    ClassificationPre-Analytical FactorValue(s)
    Analyte Extraction and PurificationAnalyte isolation method
    ExoQuick kit
    Precipitation with 10% PEG
    Precipitation with 15% PEG
    Precipitation with 20% PEG
    Precipitation with 5% PEG
    Total Exosome Isolation reagent