Skip to main content

Development of Methods to Extract RNA From Archived Pediatric Needle Liver Biopsies to Produce Sequencing Data.

Shin E, Jones-Brando LV, Florea LD, Schwarz KB, Yolken RH

Publication: J Pediatr Gastroenterol Nutr (2021) • Vol 72 • Page 436-441PMID: 33560759View on PubMed

Purpose

The purpose of this paper was to determine the optimal specimen format (unstained FFPE slide-mounted section versus FFPE block cores) and RNA extraction procedure for analysis of archived pediatric and adult liver biopsies by high throughput sequencing.  The paper also explored if informative data can be collected from archived pediatric and adult liver biopsies by high throughput sequencing as well as to investigate potential effects of FFPE block storage duration.

Conclusion

Although no differences in RNA yield or quality were reported, the authors preferred FFPE tissue cores as input material for RNA extraction due to the occasional loss of sample that occurred when unstained slide-mounted FFPE sections were transferred between processing steps. The authors noted that while the QIAGEN miRNeasy FFPE kit and the ZymoPinPoint Slide Isolation System produced RNA of comparable quantity and quality, the QIAGEN miRNeasy FFPE kit generated consistent RNA yield and quality and was more user friendly than the ZymoPinPoint Slide Isolation System. Tissue cores of archived FFPE liver biopsies generated RNA fragments of ~200 nts in length. RNA from tissue cores of archived FFPE blocks containing pediatric or adult biopsies generated a mean of 55,136,519 sequences per library. FASTQC analysis showed that RNA from 5 of 45 patients generated sequencing results that were of low quality (mean base pair quality <20) over the entire read length The fraction of human RNA (as opposed to bacterial and/or other contaminants) ranged between 14-90% across samples from the 45 patients. The year that the biopsy was procured was strongly correlated with the number of reads mapping to human RNA (r=0.717, p<1.98 x 10-07), indicating that the duration of FFPE block storage has an adverse effect on sequencing results.  However, more than 90% of reads among FFPE blocks stored for less than 10 years were classifiable by the Kraken program. The authors hypothesize that the decrease in the number of  reads mapping to human RNA with FFPE block storage may be the result of contamination over time. 

Studies (2)

Purpose

The purpose of this study was to determine the optimal specimen format (unstained FFPE slide-mounted section versus FFPE block cores) and RNA extraction method for analysis of archived pediatric and adult liver biopsies by high throughput sequencing.  Liver biopsies were collected from 34 individuals using a 15-20 gauge needle for the purpose of diagnosing a non-infectious pathology. FFPE blocks were stored for 0.5 to 20 y in the John Hopkins Hospital surgical pathology archive. Additional details on fixation, processing, and storage conditions were not provided.  FFPE liver specimens were sampled from archived blocks as tissue cores (0.6 mm diameter and 1-2 mm in length; 2-3 cores/patient) or unstained slide-mounted FFPE sections (5 µm thick sections, 2-5 sections/patient), were stored in RNase and DNase-free tubes, and were randomly assigned to one of two different RNA isolation methods (QIAGEN miRNeasy FFPE kit or the Zymo Pinpoint Slide Isolation System).  FFPE liver specimens processed using the QIAGEN miRNeasy FFPE kit were deparaffinized with QIAGEN deparaffinization solution, digested with proteinase K, and the sample was purified with RNAeasy MinElute Spin Columns.  FFPE liver specimens processed using the Zymo Pinpoint Slide Isolation System were deparaffinized in xylene, digested in proteinase K, and purified with Zymo-Spin IC Columns.  All isolated RNA was stored at -75°C until analysis for RNA yield using a Nanodrop spectrophotometer and RNA quality using an Agilent 2200 TapeStation.

Summary of Findings

The yield and quality of RNA isolated from FFPE liver biopsies using the QIAGEN miRNeasy FFPE kit and the Zymo Pinpoint Slide isolation System were comparable. However, the authors noted their preference for the QIAGEN miRNeasy FFPE kit due to technical challenges associated with the ZymoPinpoint Slide Isolation System, which included a lengthy deparaffinization step and specimen loss when the blue tape used to transfer FFPE sections shattered. While the authors did not report any differences in RNA yield or quality between the starting material for RNA extraction, FFPE cores were preferred given their consistent yield and quality and due to the loss of FFPE tissue sections during transfer to RNase/DNase-free tubes.

  • Biospecimens

    TissueLiver
  • Preservation Types

    Formalin
  • Diagnoses

    Other diagnoses
  • Platforms

    RNASpectrophotometry
    RNAAutomated electrophoresis/Bioanalyzer
  • Pre-analytical Factors

    ClassificationPre-Analytical FactorValue(s)
    Analyte Extraction and PurificationAnalyte isolation method
    QIAGEN miRNeasy FFPE kit
    Zymo Pinpoint Slide Isolation System
    Analyte Extraction and PurificationDeparaffinization
    QIAGEN deparaffinization solution
    Xylene
    Analyte Extraction and PurificationSpecimen format
    FFPE tissue core
    Unstained FFPE slide-mounted sections