The purpose of this paper was to determine the optimal specimen format (unstained FFPE slide-mounted section versus FFPE block cores) and RNA extraction procedure for analysis of archived pediatric and adult liver biopsies by high throughput sequencing. The paper also explored if informative data can be collected from archived pediatric and adult liver biopsies by high throughput sequencing as well as to investigate potential effects of FFPE block storage duration.
Development of Methods to Extract RNA From Archived Pediatric Needle Liver Biopsies to Produce Sequencing Data.
Shin E, Jones-Brando LV, Florea LD, Schwarz KB, Yolken RH
Purpose
Conclusion
Although no differences in RNA yield or quality were reported, the authors preferred FFPE tissue cores as input material for RNA extraction due to the occasional loss of sample that occurred when unstained slide-mounted FFPE sections were transferred between processing steps. The authors noted that while the QIAGEN miRNeasy FFPE kit and the ZymoPinPoint Slide Isolation System produced RNA of comparable quantity and quality, the QIAGEN miRNeasy FFPE kit generated consistent RNA yield and quality and was more user friendly than the ZymoPinPoint Slide Isolation System. Tissue cores of archived FFPE liver biopsies generated RNA fragments of ~200 nts in length. RNA from tissue cores of archived FFPE blocks containing pediatric or adult biopsies generated a mean of 55,136,519 sequences per library. FASTQC analysis showed that RNA from 5 of 45 patients generated sequencing results that were of low quality (mean base pair quality <20) over the entire read length The fraction of human RNA (as opposed to bacterial and/or other contaminants) ranged between 14-90% across samples from the 45 patients. The year that the biopsy was procured was strongly correlated with the number of reads mapping to human RNA (r=0.717, p<1.98 x 10-07), indicating that the duration of FFPE block storage has an adverse effect on sequencing results. However, more than 90% of reads among FFPE blocks stored for less than 10 years were classifiable by the Kraken program. The authors hypothesize that the decrease in the number of reads mapping to human RNA with FFPE block storage may be the result of contamination over time.
Studies (2)
Purpose
The purpose of this study was to determine the optimal specimen format (unstained FFPE slide-mounted section versus FFPE block cores) and RNA extraction method for analysis of archived pediatric and adult liver biopsies by high throughput sequencing. Liver biopsies were collected from 34 individuals using a 15-20 gauge needle for the purpose of diagnosing a non-infectious pathology. FFPE blocks were stored for 0.5 to 20 y in the John Hopkins Hospital surgical pathology archive. Additional details on fixation, processing, and storage conditions were not provided. FFPE liver specimens were sampled from archived blocks as tissue cores (0.6 mm diameter and 1-2 mm in length; 2-3 cores/patient) or unstained slide-mounted FFPE sections (5 µm thick sections, 2-5 sections/patient), were stored in RNase and DNase-free tubes, and were randomly assigned to one of two different RNA isolation methods (QIAGEN miRNeasy FFPE kit or the Zymo Pinpoint Slide Isolation System). FFPE liver specimens processed using the QIAGEN miRNeasy FFPE kit were deparaffinized with QIAGEN deparaffinization solution, digested with proteinase K, and the sample was purified with RNAeasy MinElute Spin Columns. FFPE liver specimens processed using the Zymo Pinpoint Slide Isolation System were deparaffinized in xylene, digested in proteinase K, and purified with Zymo-Spin IC Columns. All isolated RNA was stored at -75°C until analysis for RNA yield using a Nanodrop spectrophotometer and RNA quality using an Agilent 2200 TapeStation.
Summary of Findings
The yield and quality of RNA isolated from FFPE liver biopsies using the QIAGEN miRNeasy FFPE kit and the Zymo Pinpoint Slide isolation System were comparable. However, the authors noted their preference for the QIAGEN miRNeasy FFPE kit due to technical challenges associated with the ZymoPinpoint Slide Isolation System, which included a lengthy deparaffinization step and specimen loss when the blue tape used to transfer FFPE sections shattered. While the authors did not report any differences in RNA yield or quality between the starting material for RNA extraction, FFPE cores were preferred given their consistent yield and quality and due to the loss of FFPE tissue sections during transfer to RNase/DNase-free tubes.
Biospecimens
TissueLiverPreservation Types
FormalinDiagnoses
Other diagnosesPlatforms
RNASpectrophotometryRNAAutomated electrophoresis/BioanalyzerPre-analytical Factors
Classification Pre-Analytical Factor Value(s) Analyte Extraction and Purification Analyte isolation method QIAGEN miRNeasy FFPE kitZymo Pinpoint Slide Isolation SystemAnalyte Extraction and Purification Deparaffinization QIAGEN deparaffinization solutionXyleneAnalyte Extraction and Purification Specimen format FFPE tissue coreUnstained FFPE slide-mounted sections
Purpose
The purpose of this study was to determine if RNA isolated from archived pediatric FFPE liver biopsies can generate informative high throughput sequencing data. Liver biopsies were collected using a 15-20 gauge needle from pediatric and adult patients diagnosed with autoimmune hepatitis (AIH) type 1 (45 patients; 9-30 years of age) or diagnosed with a noninfectious pathology (21 patients; 4-25 years of age). FFPE blocks were stored for 0.5 to 20 y in the John Hopkins Hospital surgical pathology archive. Additional details on fixation, processing, and storage conditions were not provided. FFPE liver specimens were sampled from archived blocks as tissue cores (0.6 mm diameter and 1-2 mm in length; 2-3 cores/patient), transferred to RNase and DNase-free tubes, and stored at -20°C until RNA extraction with the QIAGEN miRNeasy FFPE kit. Isolated RNA was stored at -75°C until analysis for RNA yield using a Nanodrop spectrophotometer and RNA quality using an Agilent 2200 TapeStation. Total cDNA libraries were constructed using 7-113 ng of RNA and the Low Sample Protocol with the Illumina TrSeq Stranded Total RNA Sample Preparation Kit with Ribo-Zero. Libraries were paired-end sequenced with a Illumina HeSeq2000 with 90 million paired reads/sample.
Summary of Findings
RNA extracted from the tissue cores of archived FFPE liver biopsies was ~200 nts in length. TapeStation electropherograms of cDNA libraries from this RNA revealed peaks at 220-314 bp (which includes the 120 bp sequencing adaptors). The mean number of sequences obtained by high throughput sequencing of RNA isolated from tissue cores from archived FFPE liver biopsies was 55,136,519 per library. Based on FastQC analysis, sequencing of RNA from 5 of the 45 patient samples was of poor quality over the entire length of the read (mean base pair quality <20). The percentage of reads mapping to human RNA (as opposed to bacterial and/or other contaminants) ranged between 14-90% across samples from the 45 patients. The year that the biopsy was procured was strongly correlated with the number of reads mapping to human RNA (r=0.717, p<1.98 x 10-07) regardless of patient age or sex, which corresponds to fewer reads mapping to human RNA with longer FFPE block storage. More than 90% of reads among FFPE blocks stored for less than 10 years were classifiable by the Kraken program. The authors also note that FFPE block storage duration was also inversely proportional to the number of bacterial sequences detected in a sample, although data was not provided. The authors hypothesize that the decrease in the number of reads mapping to human RNA with FFPE block storage may be the result of contamination over time.
Biospecimens
TissueLiverPreservation Types
FormalinDiagnoses
HepatitisOther diagnosesPlatforms
RNASpectrophotometryRNAAutomated electrophoresis/BioanalyzerRNANext generation sequencingPre-analytical Factors
Classification Pre-Analytical Factor Value(s) Preaquisition Diagnosis/ patient condition Autoimmune hepatitis type ICongenital hepatic fibrosisGlycogen accumulationGranulomatous liverIron overloadSickle cell hepatopathySteatohepatitisSteatosisStorage Storage duration 0.5-20 y