This paper investigated potential effects of tourniquet time on the variability of the plasma metabolome of healthy women.
Variability of human fasted venous plasma metabolomic profiles with tourniquet induced hemostasis.
Devi S, Pasanna RM, Nadiger N, Ghosh S, Kurpad AV, Mukhopadhyay A
Purpose
Conclusion
Of the 353 metabolites identified in the plasma of healthy women,73% displayed more variability between tourniquet time-points than between individuals. Importantly, the coefficient of variance (CV) was smallest when blood was collected after the release of the tourniquet.
Studies (1)
Purpose
This study investigated potential effects of tourniquet time on the variability of the plasma metabolome of healthy women. EDTA blood was collected from five fasting, healthy (normoglycemic and normotensive) premenopausal women 1, 2, and 4 min after application of the tourniquet and then again 5 min after the tourniquet was released. EDTA blood was immediately placed on ice and stored for up to 1.5 h before plasma separation. Plasma was obtained by centrifugation at 1,166 g for 10 min at 4°C and stored at -80°C until analysis by high resolution liquid chromatography mass spectrometry.
Summary of Findings
A total of 353 metabolites were identified in the plasma of healthy women. The majority of the metabolites identified (73%) displayed more variability between tourniquet time-points than between individuals. Only 24 metabolites did not exhibit any temporal variation although variability between individuals ranged between 11.4-98.1%. Importantly, the coefficient of variance (CV) was smallest when blood was collected after the tourniquet was released.
Biospecimens
FluidPlasmaFluidBloodPreservation Types
FrozenDiagnoses
NormalPlatforms
Small moleculeLC-MS or LC-MS/MSPre-analytical Factors
Classification Pre-Analytical Factor Value(s) Biospecimen Acquisition Method of fluid acquisition Tourniquet times compared