Skip to main content

Delta-S-Cys-Albumin: A Lab Test that Quantifies Cumulative Exposure of Archived Human Blood Plasma and Serum Samples to Thawed Conditions.

Jeffs JW, Jehanathan N, Thibert SMF, Ferdosi S, Pham L, Wilson ZT, Breburda C, Borges CR

Publication: Mol Cell Proteomics (2019) • Vol 18 • Page 2121-2137PMID: 31324658View on PubMedSuggested by: Chad Borges, Arizona State University

Purpose

The purpose of this paper was to develop and validate a mass spectrometric assay (the change in S-cysteineylated form of albumin, ∆S-Cys-Alb) that can be used to quantify the cumulative exposure of frozen serum and plasma specimens to thaw temperatures (> -30°C).

Conclusion

Both initial S-Cys-Alb levels and the change in (𝛥)S-Cys-Alb levels in plasma from patients undergoing a nonacute cardiac event were modestly but significantly higher than in case-matched serum specimens (p<0001 for both).  Using time course experiments the authors determined the rate law for S-Cys-Alb formation via oxidation for delays up to 28 h at 23°C.   ∆S-Cys-Alb values of control plasma and serum samples stored at -80°C were significantly higher than case-matched specimens exposed to warmer temperatures (23°C to -20°C) for 2 to 48 h (p<0.1). When a subset of aliquots that were exposed to longer thaw durations (23°C for 24, 48, 72 h; 4°C for 7 or 14 days; -20°C for 60 or 90 days) were examined individually, all 60 samples were correctly assigned as a control (-80°C) or thawed specimens based whether ∆S-Cys-Alb values fell above or below 2.58 standard deviations of mean ∆S-Cys-Alb values for reference plasma and serum samples. .  Serum specimens from healthy donors that displayed unexpectedly elevated glucose levels and significantly lower ∆S-Cys-Alb levels than observed among serum of lung cancer patients (p<1 x 10-20) were found to have been housed in a freezer that experienced a 3-4 day power outage.  Based on the determined rate law for S-Cys-Alb formation the authors estimate that the control samples were exposed to ambient temperature (23°C) for 23 h.

Studies (2)

Purpose

The purpose of this study was to develop a mass spectrometric assay that can be used to quantify the cumulative exposure of frozen serum and plasma specimens to thaw temperatures (> -30°C). The assay developed entails quantification of the S-cysteineylated form of albumin (S-Cys-Alb) by mass spectrometry in plasma and serum specimens, initially and after sample incubation at 37°C for 18 h; thus, ∆S-Cys-Alb reflects the relative change in sample S-Cys-Alb. S-Cys-Alb levels were determined using blood collected into K2EDTA, sodium heparin, and serum tubes that were processed within 30 min of collection (plasma) or allowed to clot for 40 min (serum) prior to processing, aliquoting, and freezing at -80°C.  The reference range of S-Cys-Alb and calculated ∆S-Cys-Alb were assessed using blood from 106 patients undergoing testing for nonacute cardiac events that was collected in to K2EDTA and BD vacutainer red top serum tubes. The time course of changes in S-Cys-Alb was assessed in plasma and serum from three of the patients that were incubated at 23°C for up to 4 days, at 4°C for up to 28 days, and at -20°C for up to 65 days. ∆S-Cys-Alb was determined by mass spectrometry in plasma and serum samples following dilution (1:1000, in 0.1% TFA) and injection into the LC-MS immediately (initial S-Cys-Alb) and after incubation in a 37°C oven for 18 h (maximum S-Cys-Alb).

Summary of Findings

Both initial S-Cys-Alb levels and ∆S-Cys-Alb levels in plasma from patients undergoing a nonacute cardiac event (106 patients) were modestly but significantly higher than case-matched serum specimens  (p<0001 for both).  A timecourse experiment using plasma and serum from three patients revealed that ∆S-Cys-Alb levels were lower in both plasma and serum samples that experienced thaw conditions at 23°C for up to 4 days, at 4°C for up to 28 days, and at -20°C for up to 60 days compared to those that did not experience a thaw event. The authors inferred that S-cysteinylation occurs ex vivo in samples during exposure to temperatures <-30°C, resulting in a smaller difference between initial and maximum values of S-Cys-Alb (∆S-Cys-Alb) in thawed samples compared to those that were not thawed.  The time course experiment allowed the authors to determine the rate law for S-Cys-Alb formation via oxidation for delays at 23°C, which facilitated prediction of thaw durations.

  • Biospecimens

    FluidBlood
    FluidPlasma
    FluidSerum
  • Preservation Types

    Frozen
  • Diagnoses

    Normal
    Cardiovascular Disease
  • Platforms

    ProteinLC-MS or LC-MS/MS
  • Pre-analytical Factors

    ClassificationPre-Analytical FactorValue(s)
    Biospecimen AcquisitionBiospecimen location
    Plasma
    Serum
    StorageThaw duration
    0-28 d
    0-4 d
    0-65 d
    StorageThaw temperature/condition
    -20°C
    23°C
    4°C