Skip to main content

From Sampling to Sequencing: A Liquid Biopsy Pre-Analytic Workflow to Maximize Multi-Layer Genomic Information from a Single Tube.

Maass KK, Schad PS, Finster AME, Puranachot P, Rosing F, Wedig T, Schwarz N, Stumpf N, Pfister SM, Pajtler KW

Publication: Cancers (Basel) (2021) • Vol 13PMID: 34203921View on PubMed

Purpose

The purpose of this paper was to investigate the effects of collection tube type, storage duration, and cell-free DNA (cfDNA) isolation method used on the cfDNA and cell-free RNA (cfRNA) yield and purity from cerebrospinal fluid (CSF), blood, and plasma.

Conclusion

The largest plasma volume and highest yield of 160 bp DNA was obtained when blood was collected in Norgen tubes but more copies of RPP30 were found when collected in EDTA tubes. cfDNA yield was lower when blood was stored in preservative tubes for 7 days than 3 days. cfDNA yields were highest when extraction was with NucleoSnap or the QIAamp MinElute ccfDNA Mini Kit. DNA purity and methylation profiles were comparable in all specimens, regardless of collection tube. Bioanalyzer analysis showed that size selection using magnetic beads successfully eliminated gDNA while retaining the cfDNA, resulting in an increase in the cfDNA fraction from 81% to 95%. cfRNA concentrations were higher when extraction was with NucleoSpin rather than NucleoSnap but were lower from Streck plasma than other tube types and when blood was stored for 5 days rather than 3 days. 

DNA yields were low to undetectable in the CSF of the four healthy patients, depending on collection tube type. cfDNA and cfRNA yield increased when PBS was added to Norgen, Streck, and PAXgene tubes prior to centrifugation but this increase was only observed in all tube types when analyzed by ddPCR.

Studies (3)

Purpose

The purpose of this study was to compare the cfDNA yield and purity and cfRNA yield from EDTA plasma and blood from four healthy patients stored in Norgen cf-DNA/cf-RNA Preservative Tubes, PAXgene Blood ccfDNA Tube IVD, and Streck Cell-Free DNA BCT for 3 or 7 days. The cfDNA and cfRNA yield using the NucleoSpin and NucleoSnap kits were also compared. Blood was collected from four healthy patients in duplicate into EDTA tubes, Norgen cf-DNA/cf-RNA Preservative Tubes, PAXgene Blood ccfDNA Tube IVD, and Streck Cell-Free DNA BCT. Plasma was obtained from blood in EDTA tubes by centrifugation of blood at 1900 x g for 10 min at 4°C within 1 h of collection. Plasma was obtained from blood in the other tube types 3 days and 7 days after collection by room temperature centrifugation at 500 x g for 20 min (Norgen), 1900 x g for 15 min (PAXgene), or 1600 x g for 15 min (Streck). cfDNA and cfRNA were isolated from plasma using the NucleoSpin and NucleoSnap kits. cfDNA was quantified by bioanalyzer (160 bp DNA) and total DNA was quantified by bioanalyzer (50-7000 bp DNA) and Qubit.  cfDNA levels were also assessed by ddPCR amplification of RPP30. cfRNA was quantified by Qubit. Methylation profiles were assessed in the plasma of one patient using EPIC array.

Summary of Findings

Plasma volume was significantly higher when blood was collected into Norgen or PAXgene tubes than EDTA tubes (P<0.0001 and P=0.0021, respectively) and significantly lower when collected into Streck tubes compared to EDTA, PAXgene, and Norgen tubes (P<0.0001). Yield of 160 bp DNA was highest when blood was collected in Norgen followed by EDTA, PAX, and Streck tubes but the differences in yields per mL plasma were small with highest yields per mL from EDTA tubes and the lowest from PAXgene tubes. ddPCR amplification of RPP30 found the highest genome equivalents per tube when blood was collected in EDTA followed by PAXgene tubes but significance of differences was dependent on isolation method and storage duration. The purity of the cfDNA (ratio 146 to 176 bp DNA to 50-7000 bp DNA) was close to one in all specimens, indicating a low level of genomic contamination in all specimens, regardless of collection tube type. cfDNA yield was slightly lower from blood stored in preservative tubes for 7 days than the specimen stored in the same type of preservative tube stored for 3 days but total DNA levels were equivalent between the two timepoints for Norgen and PAXgene tubes, indicating increased leukocyte DNA contamination with processing delay in these tubes. More cfDNA was obtained when extraction was with NucleoSnap than NucleoSpin, regardless of collection tube type and storage duration. Methylation profiles were similar among plasma specimens from a single patient stored for 7 days in each of the different tube types and the fresh EDTA specimen. cfRNA yield was low from Streck plasma, regardless of extraction method. cfRNA concentrations were higher when extraction was with NucleoSpin rather than NucleoSnap (P<0.0001) and for all three preservative tube the yields were lower when blood was stored 5 days rather than 3 days.   

  • Biospecimens

    FluidPlasma
    FluidBlood
  • Preservation Types

    Other PreservativePAXgeneStreck/BCTNone (Fresh)
  • Diagnoses

    Normal
  • Platforms

    DNABisulfite conversion assay
    DNAAutomated electrophoresis/Bioanalyzer
    DNADigital PCR
    DNAFluorometry
    RNADigital PCR
    RNAFluorometry
    RNAAutomated electrophoresis/Bioanalyzer
  • Pre-analytical Factors

    ClassificationPre-Analytical FactorValue(s)
    Biospecimen AcquisitionType of collection container/solution
    EDTA tube
    Norgen tube
    PAXgene tube
    Streck tube
    Biospecimen Aliquots and ComponentsCentrifugation
    Centrifugation delays investigated
    Biospecimen PreservationType of fixation/preservation
    Blood collection tube additive
    EDTA
    StorageStorage duration
    0 days
    3 days
    7 days
    Analyte Extraction and PurificationAnalyte isolation method
    NucleoSnap
    NucleoSpin
    Digital PCR SpecificTargeted nucleic acid
    RPP30
    Fluorometry SpecificTechnology platform
    Bioanalyzer
    Qubit
    TapeStation