Skip to main content

Bicentric evaluation of stabilizing sampling tubes for assessment of monocyte HLA-DR expression in clinical samples.

Hamada S, Jeannet R, Gossez M, Cour M, Argaud L, Francois B, Daix T, Venet F, Monneret G

Publication: Cytometry B Clin Cytom (2021)PMID: 34117826View on PubMed

Purpose

The purpose of this paper was to compare the stability of monocyte human leukocyte antigen-DR isotype (mHLA-DR) levels in EDTA and Cyto-Chex BCT blood specimens from patients with the novel 2019 coronavirus disease (COVID, COVID-19, COVID19) caused by the SARS-CoV-2 virus and healthy controls.

Conclusion

mHLA-DR levels increased with room temperature storage of blood in EDTA tubes from healthy donors and patients and were 2-fold higher than baseline (<1.5 h) after 48-72 h. Levels of mHLA-DR in blood from Cyto-Chex BCT were 20% lower than in the EDTA baseline specimens and were unaffected by up to 168 h of room temperature storage.

Studies (1)

Purpose

The purpose of this study was to compare the stability of mHLA-DR levels in EDTA and CytoChex blood specimens from patients with Covid-19 and healthy controls. Blood from 12 septic COVID-19 patients and six healthy donors was simultaneously collected into EDTA tubes and Cyto-Chex BCT. mHLA-DR was quantified within 1.5 h and again after 6, 24, 48, 72, and 168 h (BCT only) at room temperature. mHLA-DR quantification included staining with QuantiBrite HLA-DR/Monocyte mixture and lysis using flow cytometry.

Summary of Findings

mHLA-DR levels increased with room temperature storage of blood in EDTA tubes from healthy donors or COVID-19 patients and were 2-fold higher than baseline (<1.5 h) after 48-72 h. Levels of mHLA-DR in blood from Cyto-Chex BCT were 20% lower than in the EDTA baseline specimens and were unaffected by up to 168 h of room temperature storage.

  • Biospecimens

    FluidBlood
  • Preservation Types

    None (Fresh)
  • Diagnoses

    Pneumonia/Respiratory Infection
    Normal
  • Platforms

    ProteinFlow cytometry
  • Pre-analytical Factors

    ClassificationPre-Analytical FactorValue(s)
    PreaquisitionDiagnosis/ patient condition
    Covid-19
    Healthy
    Biospecimen AcquisitionType of collection container/solution
    Cyto-Chex BCT
    EDTA tubes
    StorageStorage conditions
    Cyto-Chex BCT
    EDTA tube
    StorageStorage duration
    168 h
    24 h
    48-72 h
    6 h
    <1.5 h