Skip to main content

Isolation of Small Extracellular Vesicles from Human Sera.

Małys MSS, Aigner C, Schulz SMM, Schachner H, Rees AJJ, Kain R

Publication: Int J Mol Sci (2021) • Vol 22PMID: 33925027View on PubMed

Purpose

The purpose of this paper was to compare the size, number, morphology, and protein profile of small extracellular vesicles (sEVs) isolated from sera using differential ultracentrifugation (DUC) and ExoSpin.

Conclusion

More particles were isolated, the distribution of particles sizes was narrower, and the mean particle diameter was smaller when sEV isolation was with ExoSpin rather than differential ultracentrifugation (DUC). However, DUC purified sEVs had higher levels of exosomal markers and contained many cup-shaped particles consistent with exosomes which were not as apparent in ExoSpin-isolated particles. While particle number was correlated with the intensity of the exosomal marker CD9 when exosomes were isolated using DUC, particle number was correlated with Apolipoprotein B (ApoB), triglycerides, total serum cholesterol, high density lipoprotein (HDL), and low density lipoprotein (LDL) concentration when exosomes were isolated with ExoSpin. The median fluorescence intensity of all 37 exosomal proteins was also higher when sEVs were purified by DUC than ExoSpin but, as the input volume was higher in DUC, the authors state ExoSpin may be as efficient at isolating exosomes as DUC.

Studies (1)

Purpose

The purpose of this study was to compare the size, number, morphology, and protein profile of sEVs isolated from sera using DUC and ExoSpin. Blood was obtained from six healthy volunteers into No Additive VACUETTE Z Tubes. Blood was allowed to clot for 20-30 min before separation of sera by centrifugation at 2500 x g for 15 min at room temperature. Serum (2 mL) was diluted in PBS before isolation of sEVs by DUC which included centrifugation at 30,000 x g for 2 h at 4°C followed by washing of the pellet in PBS and centrifugation at 100,000 x g for 2 h at 4°C. sEVs were also isolated from 100 µL serum using ExoSpin. Particles were counted and measured by nanoparticle tracking analysis. Protein levels were quantified by ELISA (CD9, CD63, CD81, calnexin, and ApoB100) and Western blotting (CD9 and CD63). Morphology and protein expression were also evaluated by transmission electron microscopy and immuno–electron microscopy using gold-labelled secondary antibodies. Levels of 32 exosomal markers were quantified by the flow cytometry-based MACSPlex Exosome Kit.

Summary of Findings

Purification of sEVs by differential centrifugation resulted in the isolation of fewer particles overall and per mL serum than ExoSpin (2.72 x 108 versus 49.76 x 108, P=0.03147 and 0.99 x 108/mL versus 497.56 x 108/mL, P=4.114 x 10-5, respectively). The distribution of particles sizes was narrower and the mean particle diameter was smaller when sEVs isolation was with ExoSpin than DUC (132.52 ± 12.05 nm versus 148.11 ± 14.64 nm, P=0.0215). DUC-purified sEVs had higher levels of CD9, CD63, and CD81 than ExoSpin purified exosomes (P=0.031, all) indicating isolation of more exosomes. The CD9 intensity was strongly correlated with particle number when isolation was with DUC (R2=0.7703, P=0.021), but not correlated when isolated using ExoSpin (R2=0.111, P=0.842) and intensity of CD63 and CD81 were not correlated with particle number regardless of purification method. Electron microscopy confirmed 30% of the sEVs isolated by DUC were CD9 positive and 70% CD63 positive, but only a small number of the sEVs were CD9 and/or CD63 positive and instead many were positive for ApoB when isolation was by ExoSpin. The DUC-isolated sEVs contained many cup-shaped particles consistent with exosomes, but the ExoSpin vesicles contained multiple particle types of which few were exosomes. The predominant protein found in DUC-purified specimens was albumin, which was not detected in specimens purified using ExoSpin where the predominant band was >250 kDa, which the authors state is suggestive of lipoproteins. Comparable amounts of ApoB were quantified by ELISA in ExoSpin and DUC- purified sEVs (0.4 ± 0.23 and 0.39 ± 0.17, respectively). However, the ApoB, triglycerides, total serum cholesterol, HDL, and LDL concentrations were only correlated with particle number when sEVs were isolated with ExoSpin (R2= 0.8538; R2=0.9449, R2=0.5313, R2=0.4346, and R2=0.6087; respectively). Multiplex flow cytometry analysis found the fluorescence intensities of 21/37 and 10/37 exosomal proteins were above the limit of detection in sEVs isolated by DUC and ExoSpin, respectively. The median fluorescence intensity of all 37 exosomal proteins was also higher when sEVs were purified by DUC than ExoSpin (7124.80 ± 12,203.11 and 1462.42 ± 2451.13, respectively, P= 0.00012), but as the input volume was higher in DUC, the authors state ExoSpin may be as efficient at isolating exosomes as DUC.

  • Biospecimens

    FluidSerum
  • Preservation Types

    None (Fresh)
  • Diagnoses

    Normal
  • Platforms

    Cell count/volumeLight scattering
    MorphologyLight scattering
    MorphologyElectron microscopy
    ProteinLight microscopy
    ProteinWestern blot
    ProteinFlow cytometry
    ProteinELISA
    LipoproteinELISA
    SteroidELISA
    Protein1D/2D gels
    ProteinElectron microscopy
  • Pre-analytical Factors

    ClassificationPre-Analytical FactorValue(s)
    Analyte Extraction and PurificationAnalyte isolation method
    DUC
    ExoSpin
    ELISA SpecificTargeted peptide/protein
    ApoB
    CD63
    CD81
    CD9
    HDL
    LDL
    Western blot SpecificTargeted peptide/protein
    CD63
    CD9