This paper compared the yield of protein, microRNA (miRNA, miR), mRNA, and long non-coding RNA (lncRNA) expression of extracellular vesicles (EVs) isolated from plasma using different methods.
Extracellular vesicles isolated by size-exclusion chromatography present suitability for RNomics analysis in plasma.
Yang Y, Wang Y, Wei S, Zhou C, Yu J, Wang G, Wang W, Zhao L
Purpose
Conclusion
EVs isolated with Exosupur had the highest particle-to-protein ratio of the size exclusion chromatography (SEC) methods tried and was used for further comparisons. All four isolation methods tested yielded EVs of the expected size range with the expected protein biomarkers but the miRNA profiles depended on EV isolation method. ExoSupur yielded the highest particle-to-protein ratios, levels of CD9 and CD63, levels of the long chain RNAs solute carrier family 25 (SLC25A) and Phosphoglycerate Kinase 1 (PGK1), percentage of miRNA-derived reads, and LncRNA exon mapping rate. ExoQuick performed similarly to ExoSupur in terms of number of particles isolated, levels of the EV-specific miRNAs, and percentage of mRNA and lncRNA reads.
Studies (1)
Purpose
This study compared the yield of protein, miRNA, mRNA, and lncRNA expression of EVs isolated from plasma using different methods. Plasma was obtained from the EDTA blood from an unspecified number of healthy patients by centrifugation at 1600 x g for 15 min at room temperature followed by 10,000 x g for 30 min within 30 min of blood collection. EVs were isolated from plasma by ultracentrifugation, SEC, ExoQuick, or exoEasy. Ultracentrifugation included centrifugation at 2000 x g for 10 min, filtration through a 0.22 µm filter, centrifugation at 100,000 x g for 2 h at 4°C, and resuspension in PBS. Three different SEC methods were compared: ExoSupur, qEV, and 4ff. Additionally, EV isolation using ExoSupur, ExoQuick and exoEasy were compared. The concentration and size of the particles were assayed by nano-flow cytometry. EV morphology was investigated by transmission electron microscopy. Protein concentrations were quantified using the BCA assay and levels of APOB, AGO2, HSA, Alix, Tsg101, CD9, and CD63 were evaluated by Western Blot analysis. RNA was isolated from EVs using the miRNeasy Mini Kit. miRNA was quantified by NanoDrop and the Agilent Bioanalyzer 2100 System. Sequencing libraries were prepared using the Ovation SoLo RNA-Seq Library Preparation Kit and the NEB Next Multiplex Small RNA Library Prep Set for Illumina and pair-end sequenced on an Illumina Hiseq.
Summary of Findings
EVs isolated with ExoSupur had a particle-to-protein ratio close to 100% but the other SEC methods resulted in a particle-to-protein ratio of <10%, thus only ExoSupur was used in further comparisons. More particles were isolated using ExoQuick then ExoSupur (P<0.05) and using ExoSupur than ExoEasy (P<0.001) or ultracentrifugation (P<0.05). The particle-to-protein ratios were highest when EV isolation was with ExoSupur and significantly higher than when isolation was with ultracentrifugation or ExoQuick (P<0.001, both). EVs isolated using ExoQuick ranged in size to over 100 nm and had higher levels of Argonaute 2 (AGO2), human serum albumin (HSA), and apolipoprotein B (APOB) but those isolated by ultracentrifugation, ExoSupur, and exoEasy were under 100 nm and HSA and AGO2 were lowest in EVs isolated by ExoSupur. Levels of CD9 and CD63 were highest when EVs were isolated by SEV but EVs isolated using all four methods expressed all of the EV-specific markers.
Compared to ExoSupur, more miRNA was obtained from EVs isolated using ExoEasy and ExoQuick (P<0.001) and less RNA was obtained when EVs were isolated by ultracentrifugation. Levels of the EV markers miR-146, miR-150, and miR-18a were higher when EVs were isolated by ExoSupur or ExoQuick than by ultracentrifugation or ExoEasy (P<0.001) but levels of U6 were highest in EVs isolated by ExoEasy. Further, levels of the long chain RNAs SLC25A and PGK1 were higher in EVs obtained by ExoSupur than EVs obtained by ExoQuick (P<0.01 and P<0.05, respectively) and ultracentrifugation (P<0.01 and P<0.05, respectively). Further, the miRNA profiles depended on the EV isolation method with the largest percentage of miRNA-derived reads found when EVs were isolated using ExoSupur and the lowest when isolated with ExoQuick. mRNA and lncRNA reads were highest when extraction was with ExoSupur (57.49% and 6.78%, respectively) or ExoQuick (47.02% and 8.47%, respectively) and the most types of mRNA with Fragments Per Kilobase (FPKM) >5 were found when EVs were isolated with ExoSupur. LncRNA mapping rates were higher when EVs were isolated using ExoSupur and ExoEasy but the exon rate was highest using ExoSupur (63.66% versus 55.09% for ExoQuick, 4.48% for ultracentrifugation, and 4.75% for ExoEasy).
Biospecimens
FluidPlasmaPreservation Types
None (Fresh)Diagnoses
NormalPlatforms
ProteinColorimetric assayProteinWestern blotCell count/volumeFlow cytometryMorphologyElectron microscopyRNAReal-time qRT-PCRRNAAutomated electrophoresis/BioanalyzerRNASpectrophotometryRNANext generation sequencingPre-analytical Factors
Classification Pre-Analytical Factor Value(s) Analyte Extraction and Purification Analyte isolation method ExoQuickSEC with 4ffSEC with ExoSupurSEC with qEVUltracentrifugationexoEasyWestern blot Specific Targeted peptide/protein AGO2APOBAlixCD63CD9HSATsg101