Validation of a New Protocol to Collect and Isolate Plasma from Pregnant Women for Noninvasive Prenatal Testing (NIPT).

Giroux S, Badeau M, Jeuken J, Caron A, Girouard J, Rousseau F

Publication: J Appl Lab Med (2020)PMID: 33215208View on PubMed

Purpose

The purpose of this paper was to determine if collection tube type and plasma purification by filtration rather than centrifugation impacts the quality or quantity of isolated cell-free DNA (cfDNA) or the calculated cell-free fetal DNA (cffDNA) fraction.

Conclusion

Comparable cfDNA amounts, cfDNA size profiles, and cffDNA fractions were obtained from all specimens regardless of tube type (EDTA versus Streck BCT) or plasma purification method (filtration versus centrifugation).

Studies (1)

Purpose

The purpose of this study was to determine if collection tube type and plasma purification by filtration rather than centrifugation impacts the quality or quantity of isolated cfDNA or the calculated cffDNA fraction. Blood was collected from 51 pregnant women into one K2EDTA Gel Blood Tube and two Streck BCTs. Plasma was obtained by centrifugation at 1600 x g for 10 min within 6 h of blood collection. Plasma from one Streck BCT and the EDTA tube was passed through a 0.45 µm filter. The plasma from the remaining Streck tube was recentrifuged at 16000 x g for 10 min. cfDNA was isolated from the plasma using the QIAamp Circulating Nucleic Acid Kit and quantified by Qubit dsDNA HS Assay Kit. Sequencing libraries were constructed using a modification of the KAPA Hyper Prep Kit including both the Kapa Unique Dual-indexed adapters and the Illumina Unique Dual-indexed adapters. Libraries were quantified using the Kapa Library Quantification Kit and sequenced on a NovaSeq 6000. 

Summary of Findings

A comparable amount of cfDNA was obtained from all specimens regardless of tube type and plasma purification method. Further, the size profile of isolated cfDNA and sequencing library yields were comparable among the tube types and methods. Only a non-significant difference of 0.2% in the cffDNA fraction was observed in the EDTA specimen relative to the Streck specimen when purified by centrifugation and 0.4% between the Streck specimen types. Strong correlations in the cfDNA fraction were observed between the EDTA specimen purified with filtration and the Streck BCT specimens purified by centrifugation (r=0.861, P<0.0001).

  • Biospecimens

    FluidBlood
    FluidPlasma
  • Preservation Types

    None (Fresh)
  • Diagnoses

    Pregnant
  • Platforms

    DNAFluorometry
    DNANext generation sequencing
  • Pre-analytical Factors

    ClassificationPre-Analytical FactorValue(s)
    Biospecimen AcquisitionType of collection container/solution
    EDTA-gel tube
    Streck BCT
    Biospecimen Aliquots and ComponentsCentrifugation
    Different number of centrifugation steps compared
    Biospecimen Aliquots and ComponentsFiltration
    Centrifuged instead
    Filtered with 0.45 µn filter