Decreasing formalin concentration improves quality of DNA extracted from formalin-fixed paraffin-embedded tissue specimens without compromising tissue morphology or immunohistochemical staining.

Cummings M, King H, Hurst J, Tanner G, Khazin L, Thompson P, Gray A, Gahir N, Cartlidge C, Farooq Z, Raveendran K, Allen K, Rotimi O, Orsi NM

Publication: J Clin Pathol (2020) • Vol 73 • Page 514-518PMID: 31919142View on PubMed

Purpose

This paper compared the number of amplifiable copies of DNA and H&E and immunohistochemistry (IHC) staining analyses in matched liver, colon, and uterus specimens fixed for 24 or 48 h in different concentrations of formaldehyde in phosphate buffered saline (PBS). The number of amplifiable copies of DNA was also compared between DNA extracted from specimens fixed in unbuffered formal saline and 4% formaldehyde in PBS.

Conclusion

The number of amplifiable copies of Ferritin heavy chain (FTH1) was higher in DNA from colon, liver, and uterus specimens fixed in NBF (4% formaldehyde) than in matched specimens fixed in unbuffered formalin. The concentration of formaldehyde buffered in PBS but not duration of fixation significantly affected the percentage of amplifiable DNA with more amplifiable copies when fixed in lower concentrations of formaldehyde in PBS. Analysis of H&E staining by two blinded pathologists and the automated analysis found no effect of fixative concentration or duration. Although IHC staining for multicytokeratin (MCK) and α-smooth muscle actin (SMA) had comparable intensity and specificity when reviewed by blinded pathologists, the automated method found greater 3,3’-Diaminobenzidine (DAB) intensity in liver specimens fixed for 24 h in 1% formaldehyde than when fixed for 48 h in 4% or 5% formaldehyde.

Studies (1)

Purpose

This study compared the number of amplifiable copies of DNA and H&E and IHC staining analyses in matched liver, colon, and uterus specimens fixed for 24 or 48 h in different concentrations of formaldehyde in PBS. The number of amplifiable copies of DNA was also compared between DNA extracted from specimens fixed in unbuffered formal saline and 4% formaldehyde in PBS. Each of eight normal colon, liver, and uterus specimens obtained during resection were divided into 10 pieces that were <5 mm thick. Matched tissue pieces were fixed in 5%, 4%, 3%, 2%, or 1% formaldehyde in PBS; in unbuffered formal saline (4% formaldehyde); or in neutral buffered formalin (4% formaldehyde) at room temperature for 24-48 h. After fixation, specimens were placed in 70% ethanol and paraffin embedded. DNA was extracted using QIAamp DNA FFPE Tissue Kit with RNAse treatment. DNA was quantified by spectrophotometry. Amplifiable copies of DNA were determined by real-time PCR amplification of a 180 bp region of FTH1. H&E was performed on 5 µm sections using an autostainer and scored by two blinded observers as 2 if morphology was good, 1 if sub-par, and 0 if compromised. H&E staining was also evaluated by QuPath. IHC was performed on 5 µm sections using antibodies against MCK and SMA using an autostainer and staining intensity and specificity were measured using QuPath.

Summary of Findings

Although DNA quality was comparable in specimens fixed in unbuffered formal saline and 4% formaldehyde in PBS, the number of amplifiable copies of FTH1 was higher in DNA from colon, liver, and uterus specimens fixed in 4% formaldehyde in PBS than in matched specimens fixed in unbuffered formalin (P<0.01, all). The concentration of formaldehyde in PBS significantly affected the percentage of amplifiable DNA (P=1.63×10-9) with significantly more amplifiable copies when fixed for 24 h in 1% or 2% than 4% formaldehyde in PBS (P<0.01, both) or fixed for 48 h in 1, 2, or 3% rather than 4% formaldehyde (P<0.001, P<0.01, and P<0.05; respectively). However, duration of fixation did not significantly affect the number of amplifiable copies of DNA. The number of specimens scored 1 versus 2 by the histopathologists did not differ significantly among specimens fixed in the different concentrations of formaldehyde or between the two fixation durations. Further, automated analysis found no differences in mean nuclear area or number of nuclei per unit. Similarly, IHC staining for MCK and SMA had comparable intensity and specificity when reviewed by blinded pathologists. Using QuPath, no differences in SMA intensity and specificity were observed, but a significant effect of fixation time (P=0.0004) and concentration (P=0.048) on intensity was observed for MCK with greater DAB intensity when fixed for 24 h in 1% formaldehyde than when fixed for 48 h in 4% or 5% formaldehyde (adjusted P=0.046).

  • Biospecimens

    TissueColorectal
    TissueLiver
    TissueUterus
  • Preservation Types

    FormalinOther Preservative
  • Diagnoses

    NeoplasticNormal Adjacent
    Other diagnoses
  • Platforms

    DNASpectrophotometry
    DNAReal-time qPCR
    MorphologyH-and-E microscopy
    ProteinImmunohistochemistry
  • Pre-analytical Factors

    ClassificationPre-Analytical FactorValue(s)
    Biospecimen AcquisitionBiospecimen location
    Breast
    Colon
    Liver
    Biospecimen PreservationConcentration of fixative
    1%
    2%
    3%
    4%
    5%
    Biospecimen PreservationTime in fixative
    24 h
    48 h
    Biospecimen PreservationType of fixation/preservation
    Formaldehyde
    Formol saline
    Real-time qPCR SpecificTargeted nucleic acid
    FTH1
    Immunohistochemistry SpecificTargeted peptide/protein
    MCK
    SMA