This paper investigated the effects of tissue type, formalin buffering, and fixation duration by comparing histology, DNA yield, and PCR success among matched formalin-fixed paraffin-embedded (FFPE) autopsy specimens of five different tissues fixed in buffered or unbuffered formalin for 6 h up to 2 months. The effect of DNA extraction method on DNA yield and purity and subsequent PCR success was also evaluated.
Effect of formalin fixation on pcr amplification of DNA isolated from healthy autopsy tissues.
Vitošević K, Todorović M, Varljen T, Slović Ž, Matić S, Todorović D
Purpose
Conclusion
Although specimens fixed in buffered and unbuffered formalin generally had comparable tissue architecture as well as cytological and nuclear details regardless of fixation duration, staining was slightly better when fixed and stored in buffered formalin. Although DNA yield and quality did not differ between specimens fixed in buffered and unbuffered formalin, amplification success was significantly lower in specimens fixed in unbuffered formalin than buffered formalin at each fixation duration. DNA yields and purity were higher when extraction was with the phenol-chloroform-isoamyl alcohol method rather than the PureLink Kit. Prolonged fixation in either fixative had an adverse effect on PCR success with amplification only possible for the longest amplicon (407 bp) when fixed for ≤72 h in buffered formalin or ≤6 h in unbuffered formalin and for the shortest amplicon (150 bp) when fixed for ≤28 days in buffered formalin or ≤7 days in unbuffered formalin. The effects of formalin buffering and fixation duration were observed in all five tissue types examined.
Studies (1)
Purpose
This study investigated the effects of tissue type, formalin buffering, and fixation duration by comparing histology, DNA yield, and PCR success among matched FFPE autopsy specimens of five different tissues fixed in buffered or unbuffered formalin for 6 h up to 2 months. The effect of DNA extraction method on DNA yield and purity and subsequent PCR success was also evaluated. Two specimens from each heart, liver, brain, lung, and kidney were obtained during autopsy from two previously healthy people who suffered a violent death. The post-mortem interval before autopsy was 24 h at 4°C. Each of the samples was further divided into subspecimens which were fixed in 10% phosphate buffered saline (PBS) or 4% unbuffered formalin for 6 h, 24 h, 48 h, 72 h, 96 h, 5 days, 6 days, 7 days, 10 days, 14 days, 28 days, or 2 months at room temperature. Following fixation, specimens were processed on an automated tissue processor and the resultant FFPE blocks were stored at room temperature until use. The first and last section of each block were H&E stained. DNA was extracted from 4-8 µm sections using phenol-chloroform-isoamyl alcohol and the commercial PureLink Genomic DNA Mini Kit and then stored at -20°C. DNA was quantified by spectrophotometer. Maximum fragment size was evaluated by PCR amplification of GPD1 (glycerol-3-phosphate dehydrogenase), ACTB (ß-actin), and RPL4 (ribosomal protein L4) genes and gel electrophoresis.
Summary of Findings
Tissue architecture as well as cytological and nuclear details were equivalent in specimens fixed in buffered and unbuffered formalin but staining was slightly better when fixed and stored in buffered formalin. There seemed to be no clear effect of prolonged fixation on histology. DNA yield and quality did not differ between specimens fixed in buffered and unbuffered formalin but were higher when extraction was with the phenol-chloroform-isoamyl alcohol method rather than the PureLink Kit. PCR success was significantly higher in specimens fixed in buffered formalin than unbuffered formalin at all timepoints. Prolonged fixation in either fixative had an adverse effect on PCR success with the 407 bp fragment of RPL4 amplifiable only in specimens fixed for ≤72 h in buffered formalin or ≤6 h in unbuffered formalin; however, fragment size was a confounding factor as the 150 bp fragment of GPD1 and the 252 bp fragment of ACTB were amplifiable in specimens fixed in buffered formalin for ≤28 days and ≤14 days; respectively, and in unbuffered formalin for ≤7 days and ≤5 days, respectively. PCR success like DNA yield was also dependent on extraction method with a lower PCR success rate found after extraction with PureLink rather than phenol-chloroform-isoamyl alcohol for specimens fixed for ≥72 h (P<0.05, all). Significant differences in band intensity between adjacent timepoints were found between specimens fixed in buffered formalin for 24 and 48 h (p=0.046), 48 h and 72 h (P=0.021), and 28 days and 2 months (P=0.046) and in unbuffered formalin for 6 and 24 h (P=0.018). The effects of formalin buffering and fixation duration were observed in all five tissue types examined.
Biospecimens
TissueBrainTissueHeartTissueLiverTissueLungTissueKidneyPreservation Types
FormalinDiagnoses
AutopsyNormalPlatforms
DNAPCRDNASpectrophotometryMorphologyH-and-E microscopyPre-analytical Factors
Classification Pre-Analytical Factor Value(s) Biospecimen Acquisition Biospecimen location BrainHeartKidneyLiverLungBiospecimen Preservation Time in fixative 10 days14 days2 months24 h28 days48 h5 days6 days6 h7 days72 h96 hBiospecimen Preservation Type of fixation/preservation Formalin (buffered)Formalin (unbuffered)Analyte Extraction and Purification Analyte isolation method PCIPureLink KitPCR Specific Length of gene fragment 150 bp252 bp406 bpPCR Specific Targeted nucleic acid ACTBGPD1RPL4