This paper compared platelet counts, microRNA (miRNA, miR) miR-16 levels, platelet viability, and microbial contamination in platelet concentrates (PCs) stored at room temperature for up to 7 days in Composol with those stored in plasma.
The Effect of Composol Medium on miR-16 Expression during Platelet Storage up to Day 7 at Room Temperature.
Rajabi A, Sharifi Z, Yari F, Deyhim MR, Jalili MA
Purpose
Conclusion
The Composol PCs had a slightly lower mean platelet count than the plasma PCs on Day 1, which the authors attribute to the additional centrifugation step as the counts were identical prior. miR-16 levels were lower in the PCs in Composol than plasma, but the differences were only significant in PCs stored for ≤5 days. Mean miR-16 levels in plasma PC concentrates were higher on Days 3 and 5 compared to Day 1 in both groups. As expected, platelet viability declined with storage, but the decline was slower in the PCs in Composol resulting in significant differences in viability between the groups on Days 3 and 5. Microbial contamination was not found in any of the specimens.
Studies (1)
Purpose
This study compared platelet counts, miR-16 levels, platelet viability, and microbial contamination in PCs stored at room temperature for up to 7 days in Composol with those stored in plasma. Platelet concentrates were prepared according to the Iranian Blood Transfusion Organization methods from the blood of 10 healthy donors. Platelets were counted using a Sysmex K-1000 Hematology Analyzer and the bags were divided into two bags using a connective device. Both bags were centrifuged at 5000 x g for 6 min at 22°C. From one bag, 70% of the plasma was removed and Composol-PS was added while the plasma was retained in the other bag. Both bags were stored on a shaker at 20-24°C for one week. Bags were sampled on Days 1, 3, 5, and 7. Samples were centrifuged at 96 x g for 4 min to reduce white blood cells before miRNA extraction using SanPrep column microRNA Mini-Prep Kit. miR-16 and RNU were quantified using the BONmiR qPCR Kits and miR-16 levels were normalized to RNU6. Bacterial contamination was evaluated in samples collected on Days 1 and 7 by culture. Platelet viability was assessed using the WST-1 Cell Proliferation Assay Kit and an optical density microplate reader.
Summary of Findings
The Composol PCs had a slightly lower mean platelet count than the plasma PCs on Day 1 (0.99 ± 0.08×1012 platelets/L versus 1.15 ± 0.10×1012 platelets/L), which the authors attribute to the additional centrifugation step as the counts were identical prior. miR-16 levels were lower in the PCs in Composol than plasma (mean 0.356-fold) but the differences were only significant (P<0.05) in PCs stored for ≤5 days. Compared to Day 1, mean miR-16 levels in plasma PC concentrates were 2.58-fold higher on Day 3 (P=0.027) and 4.87-fold higher on Day 5 (P=0.037), but only non-significantly higher on Day 7 (2.95-fold, P=0.124). Similarly, when PCs were stored with Composol, significantly higher mean levels of miR-16 were found after 3 days (2.70-fold, P=0.029) or 5 days (3.13-fold, P=0.048) compared to Day 1 but only a non-significant difference was found at Day 7 (2.48-fold, P=0.115). As expected, platelet viability declined with storage but the decline was slower in the PCs in Composol, resulting in significant differences in viability between the groups on Days 3 (P=0.034) and 5 (P=0.049), but not Day 7. Microbial contamination was not found in any of the specimens.
Biospecimens
FluidBloodPreservation Types
None (Fresh)Diagnoses
NormalPlatforms
Cell count/volumeHematology/ auto analyzerCell count/volumeSpectrophotometryCell count/volumeMicrobiological assayRNAReal-time qRT-PCRPre-analytical Factors
Classification Pre-Analytical Factor Value(s) Storage Short-term storage solution ComposolPlasmaStorage Storage duration 1 day3 days5 days7 daysReal-time qRT-PCR Specific Targeted nucleic acid RNU6miR-16