Skip to main content

Feasibility of using alternative swabs and storage solutions for paired SARS-CoV-2 detection and microbiome analysis in the hospital environment.

Minich J, Ali F, Marotz C, Belda-Ferre P, Chiang L, Shaffer JP, Carpenter CS, McDonald D, Gilbert J, Allard SM, Allen EE, Knight R, Sweeney DA, Swafford AD

Publication: Res Sq (2020)PMID: 32839765View on PubMed

Purpose

This paper compared detection SARS-CoV-2, the virus that causes the novel 2019 coronavirus disease (COVID, COVID-19, COVID19) in viral transport media (VTM) and ethanol after short-term storage of nasopharyngeal swabs and among six different swab types. The effects of swab type on environmental detection of SARS-CoV-2 RNA by real-time RT-PCR and detected microbial analysis by next-generation sequencing (NGS) were also investigated.

Conclusion

Significantly less RNAse P RNA was recovered from the ethanol than from the VTM or the swab head when RNA was extracted from the storage media, but viral RNA levels were comparable between the swab head stored in ethanol as the VTM. While recovery of RNA was comparable between 95% ethanol and 91% isopropanol, 95% ethanol provided better protection against RNAse A than 91% isopropanol. The yield of RNA was significantly affected by swab type (Kruskal-Wallis P=0.03), with the highest yields occurring with the CVS nonsterile, cotton-head, plastic-shaft, consumer-grade swabs (CGp) followed by the non-sterile, cotton-head, plastic-shaft swabs in use by TMI (TMI) and BD synthetic rayon-head, plastic-shaft swabs (SYN).  

The false negative rate for SARS CoV-2 was 12.5% for SYN swabs stored in VTM and 44%, 33%, and 50% for SYN, CGP, and TMI swabs stored in ethanol, respectively. When only swabs collected within 72 h of initial positive test were considered, the false negative rates for Syn, CGp, and TMI swabs stored in ethanol decreased to 18.2%, 25%, and 30%, respectively. Importantly, there were no false positives in the swabs from the four patients who did not have SARS-CoV-2. In floor swabs, the highest rate of detection of SARS-CoV-2 was found using the CGp swabs, but swab type had no effect on detection in bed rail specimens. NGS read counts varied between patients and tended to be higher in patient than floor specimens, with less variability observed between swab types than patients. Principle component analysis grouped specimens by patient rather than by swab type with distinct clusters observed for each patient and between floor and patient samples. Not surprisingly, microbial diversity was higher in floor than patient specimens.

Studies (2)

Purpose

This study compared detection of SARS-CoV-2 RNA in viral transport media (VTM) and ethanol after short-term storage of nasopharyngeal swabs and between the swab head and the ethanol in which it was stored. Using commercial RNA, the authors also investigated the effects of ethanol and isopropanol on the recovery of RNA and the susceptibility of the specimen to RNAse treatments. Nasopharyngeal swabs were obtained from 39 patients with SARS-CoV-2 by inserting the swab 2-3 cm into the nostril and rotating for 5-10 sec. After collection, swabs were placed in VTM and transported on dry ice. Additional specimens were collected from the nares of 11 SARS-Cov-2 patients and 11 healthcare workers using sterile synthetic-head, plastic-shaft swabs, placed in 95% ethanol and stored on dry ice. RNA was extracted from the swab eluents using the Omega Mag-Bind Viral DNA/RNA 96 Kit and from the swab heads using the MagMAX Microbiome Ultra Kit. Human RNAse P and SARS-CoV-2 RNA were quantified by real-time PCR. Extraction efficiency was evaluated by spiking SARS-CoV-2 RNA into 95% ethanol and 91% isopropanol with or without 0, 2.5, or 25 µg RNAse A.

Summary of Findings

Significantly less human RNAse P RNA was recovered from the ethanol than from the VTM (P<0.001) when RNA was extracted from the storage media, but comparable viral RNA levels were obtained from the swab head stored in ethanol as from the VTM. The SARS-CoV-2 viral RNA load was also significantly higher in the swab specimen than in the ethanol in which it was stored (P=0.032). Using commercial RNA, the authors found that 49.5% of the RNA was recoverable when no buffer was used and 32.1% and 35.3% of RNA were recoverable from 95% ethanol and 91% Isopropanol, respectively. Importantly, 95% ethanol provided better protection against RNAse A than 91% isopropanol.

  • Biospecimens

    CellNasal cavity
  • Preservation Types

    EthanolFrozen
  • Diagnoses

    Pneumonia/Respiratory Infection
  • Platforms

    RNAReal-time qRT-PCR
  • Pre-analytical Factors

    ClassificationPre-Analytical FactorValue(s)
    StorageShort-term storage solution
    91% Isopropanol
    95% Ethanol
    VTM
    Real-time qRT-PCR SpecificTargeted nucleic acid
    RNAseP
    SARS-CoV-2