This paper compared levels of hemoglobin, lactate dehydrogenase (LDH), and cell-free DNA (cfDNA) between plasma obtained from blood hemolyzed by passage through a thin needle and plasma from non-hemolyzed blood. The relationship between cfDNA levels and hemoglobin and LDH was also examined.
The Effect of In Vitro Hemolysis on Measurement of Cell-Free DNA.
Nishimura F, Uno N, Chiang PC, Kaku N, Morinaga Y, Hasegawa H, Yanagihara K
Purpose
Conclusion
As expected, hemolysis and LDH levels in plasma increased with increasing passages of blood through a 26-gauge needle but there was a high degree of interindividual variability in the magnitude of the changes. Levels of RNAse P and β-globin in plasma also increased with each passage of the blood through a 26-gauge needle and were modestly to strongly correlated with both free hemoglobin and LDH levels.
Studies (1)
Purpose
This study compared levels of hemoglobin, LDH, and cfDNA between plasma obtained from blood hemolyzed by passage through a thin needle and plasma from non-hemolyzed blood. The relationship between cfDNA levels and hemoglobin and LDH was also examined. Blood was obtained from each of 10 healthy volunteers into four heparin tubes. Blood in one tube was not damaged while hemolysis was induced in the remaining tubes of blood from each patient by passage through a 26-gauge needle once, twice, or three times. The blood was centrifuged at 1700 x g for 5 min to obtain plasma. Hemoglobin levels were measured using a Hitachi 7011 spectrometer and lactate dehydrogenase quantified using a Biomajesty clinical chemistry autoanalyzer. Plasma was recentrifuged at 14000 x g for 15 min and the supernatants stored at -80°C overnight before DNA extraction using the QIAamp DNA Blood Mini Kit. RNase P and β-globin levels in plasma were quantified by digital PCR.
Summary of Findings
As expected, hemolysis in plasma increased with increasing passages of blood through a 26-gauge needle, with significant differences from non-damaged blood noted after one, two, or three passages (11.5 mg/dL, 25.5 mg/dL, and 39 mg/dL; respectively, versus 1 mg/dL; P<0.001, all). However, there was a high degree of variability between patients in the extent of hemolysis, with a range of hemoglobin levels between 21 and 82 mg/dL observed after three passages. Similarly, LDH in plasma increased with each passage through the needle (P<0.01 after one passage and P<0.001 after two or three passages). Levels of RNAse P and β-globin in plasma increased comparably after passage of the blood through a 26-gauge needle once (~2-fold, P<0.05 and ~1.9-fold, P<0.05; respectively), twice (~2.5-fold, P<0.01 and ~2.3-fold, P<0.01; respectively) and three-times (4.8-fold, P<0.001 and 4.6-fold, P<0.001; respectively). Levels of RNAse P and β-globin in plasma were modestly to strongly correlated with free hemoglobin (R=0.6958, P<0.0001 and R=0.6916, P<0.0001; respectively) and LDH levels (R=0.7163, P<0.0001 and R=0.7132, P<0.0001; respectively).
Biospecimens
FluidBloodFluidPlasmaPreservation Types
FrozenNone (Fresh)Diagnoses
NormalPlatforms
ProteinSpectrophotometryProteinClinical chemistry/auto analyzerDNADigital PCRPre-analytical Factors
Classification Pre-Analytical Factor Value(s) Biospecimen Aliquots and Components Hemolysis Fine needle aspiration-inducedNot induced