The purpose of this paper was to identify potential effects of centrifugation speed (400 to 2,000 g) and post-centrifugation storage at 4°C for up to 24 h on the number and viability of peripheral blood leukocytes isolated from EDTA blood of young healthy volunteers. The distribution of peripheral blood leukocytes within and below the buffy coat layer was also investigated at different centrifugation speeds. Potential effects of short-term frozen storage of isolated peripheral blood leukocytes (-80°C for up to 1 month) on DNA yield and quality were also evaluated in EDTA plasma specimens.
Biostorage and quality control for human peripheral blood leukocytes.
Zhou J, Wu J, Zhao X, Shen W, Liu X, Xu C, Jin H
Purpose
Conclusion
Centrifugation speed significantly affects both the volume of plasma and the number of leukocytes obtained from EDTA blood specimens. Significantly more leukocytes were isolated from EDTA blood after centrifugation at 800 g when compared to 400 g (4.2 - 4.9 x107 cells vs. 2.98 x107; p=0.023). Significantly greater plasma volumes were obtained when EDTA blood was centrifuged at ≥1,200 g compared to 400 g (1214-1218 vs. 936 µl, respectively; p=0.006). The authors estimated that up to 70% of leukocytes in a collection tube were located in the 600 µl containing and immediately below the buffy coat when EDTA blood was centrifuged at ≥800 g. Conversely, post-centrifugation storage of whole blood at 4°C for up to 24 h prior to buffy coat collection did not affect the number or viability of leukocytes isolated from the buffy coat of EDTA blood specimens. Frozen storage of isolated leukocytes from EDTA blood at -80°C for up to a month did not significantly affect DNA yield, or quality as determined by gel electrophoresis and multiplex PCR of amplicons up to 600 bp.
Studies (3)
Purpose
The purpose of this study was to determine if centrifugation speed affects the number of peripheral blood leukocytes recovered from EDTA blood, their vertical distribution within the collection tube, or the volume of plasma obtained. A total of 50 ml of blood from six healthy female volunteers (24-34 y) was collected into tubes containing EDTA. Blood (3 ml from each volunteer) was then centrifuged at 400 g, 800 g, 1200 g, 1600 g, and 2000 g at 4°C. The total volume of plasma collected after centrifugation was determined. Aliquots (300 µl per layer) were collected from each specimen after centrifugation based on a vertical gradient relative to the buffy coat (layer 1, included the buffy coat; layer 2; 3; 4; 5, bottom of the tube). White blood cells were quantified in each layer using a hematology analyzer. DNA was extracted from buffy coats using the AxyPrep Blood Genomic SNA Miniprep Kit, then quantified with a NanoQuant spectrophotometer.
Summary of Findings
The number of peripheral blood leukocytes retrieved from EDTA blood specimens, as well as their vertical distribution within the tube were both influenced by centrifugation speed. Significantly more leukocytes were isolated from the buffy coat of EDTA blood when centrifuged at 800 g compared to 400 g (4.2 - 4.9 x107 cells vs. 2.98 x107; p=0.023). A greater percentage of leukocytes were isolated from the buffy coat when EDTA blood was centrifuged at ≥800 g than 400 g (~50% versus 28%, respectfully). When EDTA blood specimens were centrifuged at ≥800 g approximately 70% of peripheral blood leukocytes were retrieved from the uppermost two layers of the blood cell pack (the 600 µl closest to and including the buffy coat), with the remaining leukocytes distributed among layers of erythrocytes. A centrifugation speed ≥ 1200 g resulted in a significantly higher plasma volume than obtained after a 400 g centrifugation (1214-1218 vs. 936 µl, respectively; p=0.006).
Overall, the authors observed a positive relationship between DNA yield and the number of peripheral blood leukocytes.
Biospecimens
FluidBloodFluidBuffy CoatFluidPlasmaCellWhite CellsPreservation Types
None (Fresh)Diagnoses
NormalPlatforms
Cell count/volumeHematology/ auto analyzerDNASpectrophotometryPre-analytical Factors
Classification Pre-Analytical Factor Value(s) Biospecimen Aliquots and Components Blood and blood products Buffy coatBuffy coat with red blood cellsBiospecimen Aliquots and Components Centrifugation Multiple speeds compared
Purpose
The purpose of this study was to determine if a delay at 4°C after centrifugation adversely affects the number or viability of peripheral blood leukocytes isolated from buffy coat. Blood from eleven healthy female volunteers (24-34 y) was collected into tubes containing EDTA, and centrifuged at 800 g at 4°C for 10 min. Specimens then experienced a post-centrifugation delay at 4°C of 0, 8, 16, or 24 h prior to removal and analysis of the buffy coat. The number of leukocytes in each sample was quantified by a hematology analyzer. Cell viability was assessed using trypan blue and lactate dehydrogenase (LDH) assays, which are hallmarks of membrane integrity.
Summary of Findings
Post-centrifugation storage at 4°C for up to 24 h did not significantly alter the number of peripheral blood leukocytes nor their viability (determined by trypan blue and LDH assays). The number of leukocytes isolated ranged between 3.8 and 4.7 x 107 cells for a 3 ml aliquot.
Biospecimens
FluidBuffy CoatCellWhite CellsPreservation Types
None (Fresh)Diagnoses
NormalPlatforms
Cell count/volumeHematology/ auto analyzerCell count/volumeColorimetric assayCell count/volumeChemiluminescencePre-analytical Factors
Classification Pre-Analytical Factor Value(s) Storage Storage duration 0 h at 4 degrees C16 h at 4 degrees C24 h at 4 degrees C8 h at 4 degrees C
Purpose
The purpose of this study was to assess the effects of short-term frozen storage of isolated peripheral blood leukocytes on DNA yield and quality. Blood from eleven healthy female volunteers (24-34 y) was collected into tubes containing EDTA, centrifuged at 800 g at 4°C for 10 min, and the buffy coat was removed. Buffy coat specimens underwent DNA extraction immediately or were frozen at -80°C for 1 h, 1 week, or 1 month before DNA isolation and analysis. DNA was extracted from buffy coats using the AxyPrep Blood Genomic SNA Miniprep Kit, then quantified with a NanoQuant spectrophotometer. DNA quality was determined by gel electrophoresis, and multiplex PCR for 100, 200, 300, 400 and 600 bp amplicons.
Summary of Findings
DNA yield and quality were not significantly affected by frozen storage of buffy coat specimens at -80°C for up to 1 month. Amplification of the 600 bp product was successful for all samples regardless of frozen storage duration. High molecular weight DNA (~48.5 kb) was also observed in all samples.
Biospecimens
FluidBuffy CoatPreservation Types
None (Fresh)FrozenDiagnoses
NormalPlatforms
DNASpectrophotometryDNAElectrophoresisDNAPCRPre-analytical Factors
Classification Pre-Analytical Factor Value(s) Storage Storage duration 1 h at -80 degrees C1 month at -80 degrees C1 week at -80 degrees CFresh/ Not frozen