Influence of delayed separation of plasma from whole blood and centrifugation protocol on Zn plasma concentration.

Leger M, Despinasse Q, Faure P, Arnaud J, Ravelet C, Chovelon B

Publication: Clin Chem Lab Med (2020)PMID: 32609637View on PubMed

Purpose

The purpose of this paper was to investigate the effects of delayed centrifugation of blood and centrifugation speed on zinc levels in plasma from volunteers.

Conclusion

The authors conclude the acceptable delay for analysis of zinc is 1 h as increases in zinc levels exceeding the total change limit (TCL) were observed when stored for 2 h prior to centrifugation. However, zinc levels were comparable when centrifugation was at 1300 x g versus 2000 x g or at 2,500 x g for 15 min versus 2000 x g for 10 min.

Studies (2)

Purpose

The purpose of this study was to investigate the effects of delayed centrifugation of blood and centrifugation speed on zinc levels in plasma from volunteers. Blood was collected from 32 members of the laboratory staff into sodium heparin tubes and aliquoted. Specimens were stored at room temperature for 0, 1, 2, 3, and 4 h before centrifugation at 1300 x g for 10 min or 2000 x g for 10 min. Plasma was transferred to polypropylene tubes and frozen at -20°C. Plasma was thawed immediately before analysis of zinc levels by inductively-coupled plasma mass spectrometry (ICP-MS) in the same run. Changes were compared to the total change limit (TCL) and reference change value (RCV) which are determined based on within-run imprecision and intra-individual variability.

Summary of Findings

Zinc levels increased with increasing delay to centrifugation and increases exceeded the TCL when specimens were stored for 2 h or more before centrifugation (6.75% at 2 h versus TLC of 5.03%) but the differences remained less than the RCV of 23.0%. ANOVA analysis identified no effects of centrifugation speed on levels of zinc.

  • Biospecimens

    FluidBlood
    FluidPlasma
  • Preservation Types

    Frozen
  • Diagnoses

    Normal
    Not specified
  • Platforms

    Electrolyte/MetalInductively coupled plasma mass spectrometry
  • Pre-analytical Factors

    ClassificationPre-Analytical FactorValue(s)
    Biospecimen Aliquots and ComponentsCentrifugation
    Centrifugation delays investigated
    Multiple speeds compared
    StorageTime at room temperature
    0 h
    1 h
    2 h
    3 h
    4 h