Skip to main content

Comparison of nasopharyngeal nylon flocked swabs with universal transport medium and rayon-bud swabs with a sponge reservoir of viral transport medium in the diagnosis of paediatric influenza.

Esposito S, Molteni CG, Daleno C, Valzano A, Cesati L, Gualtieri L, Tagliabue C, Bosis S, Principi N

Publication: J Med Microbiol (2010) • Vol 59 • Page 96-99PMID: 19815662View on PubMed

Purpose

This paper compared detection of influenza in children between nasopharyngeal specimens collected with a nylon flocked swab and stored in universal transport medium (UTM) and those collected using a shafted rayon-budded swab and transported in viral transport medium (VTM).

Conclusion

Influenza A and B detection rates and cycle threshold (CT) values were comparable between flocked swab specimens in UTM and rayon swab specimens in VTM. 

Studies (1)

Purpose

This study compared detection of influenza in children between nasopharyngeal specimens collected with a nylon flocked swab and stored in UTM and those collected using a plastic-shafted rayon-budded swab transported in VTM. Specimens were collected from 314 children (186 males, 128 females; mean age 2.32 ± 2.27 years) with influenza-like illness defined as an acute respiratory disease of sudden onset with fever >38°C, at least one general symptom (headache, generalized malaise, a feverish sensation, or asthenia), and at least one respiratory symptom (cough, pharyngodynia, or nasal congestion). In a randomized order, nasopharyngeal specimens were collected using a nylon flocked swab and rayon-budded swab (one swab per nostril) gently inserted towards the pharynx until resistance was felt, rotated three times, and then withdrawn and put into the tube containing the specific transport medium (nylon swab in universal transport medium and rayon swab in viral transport medium). Specimens were kept cool by an unspecified method and delivered to the laboratory within 3 h of collection. RNA was extracted directly from 190 µl UTM of nylon flocked swab specimens. For rayon swab specimens, tubes were vortexed and incubated for 10 min at room temperature before extraction. RNA was extracted from all specimens using an EasyMAG automated extraction system. Influenza A and B RNA was detected by real-time RT-PCR.

Summary of Findings

Influenza A and B detection rates were comparable between flocked swab specimens in UTM and rayon swab specimens in VTM (8.9% versus 8.3% and 14.3% versus 13.7%, respectively). Cycle threshold (CT) values for influenza A and B were also similar between flocked and nylon swab specimens (28.71 ± 4.61 versus 29.95 ± 5.16 and 30.70 ± 5.48 versus 31.20 ± 5.57, respectively).

  • Biospecimens

    CellNasopharynx
  • Preservation Types

    None (Fresh)
  • Diagnoses

    Pneumonia/Respiratory Infection
  • Platforms

    RNAReal-time qRT-PCR
  • Pre-analytical Factors

    ClassificationPre-Analytical FactorValue(s)
    Biospecimen AcquisitionMethod of cell acquisition
    Nylon flocked swab in universal transport medium
    Rayon-budded swab in viral transport medium
    StorageShort-term storage solution
    Universal transport medium
    Viral transport medium
    Real-time qRT-PCR SpecificTargeted nucleic acid
    Influenza A
    Influenza B