Skip to main content

Comparison of stool collection and storage on Whatman FTA Elute cards versus frozen stool for enteropathogen detection using the TaqMan Array Card PCR assay.

Lalani T, Tisdale MD, Liu J, Mitra I, Philip C, Odundo E, Reyes F, Simons MP, Fraser JA, Hutley E, Connor P, Swierczewski BE, Houpt E, Tribble DR, Riddle MS

Publication: PLoS One (2018) • Vol 13 • Page e0202178PMID: 30165370View on PubMed

Purpose

This paper compared the detection of enteropathogens by real-time PCR in fecal specimens stored on Whatman FTA Elute cards to those stored frozen.

Conclusion

The overall detection rate for enteropathogens was comparable between frozen specimens and those on FTA cards. Using the frozen specimen as reference, the overall sensitivity and specificity for enteropathogens of specimens on FTA cards was 72.9% and 98.0%, respectively. Cycle threshold (CT) values were higher for specimens on FTA cards. Sensitivity for all enteropathogens, enteropathogenic Escherichia coli, enteroaggregative Escherichia coli, Campylobacter, and norovirus was lower for specimens on FTA cards compared to frozen specimens, which the authors attribute to the difference in sampling volumes (200 μL of frozen feces vs. approximately <20 μL from punches of the FTA card).

Studies (1)

Purpose

This study compared detection of enteropathogens by real-time PCR in f fecal specimens stored on Whatman FTA Elute cards to those stored frozen. Matched specimens were collected from 187 patients diagnosed with traveler’s diarrhea (defined by ≥3 unformed stools in 24 hours or >2 stools in 24 hours associated with nausea, vomiting, abdominal cramps, or tenesmus). Specimens were processed in on-site laboratories by applying a thin smear of fresh diarrheal fecal specimens across a FTA card using a wooden applicator and then air-dried for 30 minutes, placed in a pouch with a desiccant, sealed, and stored at room temperature. An aliquot of 180-220 mg of feces (200 μL if liquid) was placed in a cryovial and stored at -80°F. Specimens were stored for a median of 712 days (range of 396-750 days) before shipment. The FTA cards were shipped at ambient temperature and frozen specimens were shipped on dry ice to the testing lab. DNA and RNA were extracted from frozen stool samples using the modified QIAamp Fast DNA Stool Mini Kit and from smears on FTA cards from three, 3 mm discs punched from the sample area that were pulse vortexed with sterile water, subjected to bead beating, and then incubated at 95°C for 5 mins. DNA extracted from frozen specimens and eluent from FTA cards were stored at -20°C until real-time RT-PCR using the TaqMan® Array Card PCR platform for detection of 20 common diarrheal pathogens.

Summary of Findings

The overall detection rate for enteropathogens was comparable between frozen specimens and those on FTA cards (78.6% and 73.2%, respectively; P=0.22) with a positive percent agreement of 76.1% and negative percent agreement of 99.3% (overall diagnostic agreement of 0.80). Using the frozen specimen as reference, the overall sensitivity and specificity for enteropathogens for specimens on FTA cards was 72.9% and 98.0%, respectively. Cycle threshold (CT) values were higher for specimens on FTA cards. Sensitivity for all enteropathogens, enteropathogenic Escherichia coli, enteroaggregative Escherichia coli, Campylobacter, and norovirus was lower for specimens on FTA cards compared to frozen specimens, which the authors attribute to the difference in sampling volumes (200 μL of frozen feces vs. approximately <20 μL from punches of the FTA card). Mixed infections were common but there was no significant difference between frozen specimens and those on FTA cards in the average number of pathogens (1.4 +/- 1.1 versus 1.2 +/- 1.0 pathogens; P=0.16).

  • Biospecimens

    FluidFeces
  • Preservation Types

    FrozenNone (Fresh)
  • Diagnoses

    Other diagnoses
  • Platforms

    DNAReal-time qPCR
    RNAReal-time qRT-PCR
  • Pre-analytical Factors

    ClassificationPre-Analytical FactorValue(s)
    Biospecimen PreservationType of fixation/preservation
    Air-dried
    Frozen
    StorageStorage conditions
    Frozen at -80°F
    Room temperature on FTA card
    Real-time qRT-PCR SpecificTargeted nucleic acid
    Adenovirus hexon
    Astrovirus capsid
    Cryptosporidium 18S rRNA
    Cyclospora 18S rRNA
    Entamoeba histolytica 18S rRNA
    Giardia 18S rRNA
    Norovirus GI ORF1-2
    Norovirus GII ORF1-2
    Rotavirus NSP3
    Sapovirus RdRp
    Real-time qPCR SpecificTargeted nucleic acid
    Aeromonas aerolysin
    C. jejuni cadF
    Campylobacter cpn60
    Clostridium difficile tcdA
    Clostridium difficile tcdB
    Enteroaggregative E. coli aaiC
    Enteropathogenic E. coli bfpA
    Enteropathogenic E. coli eae
    Enterotoxigenic E. coli LT
    Enterotoxigenic E. coli STh
    Enterotoxigenic E. coli STp
    Salmonella invA
    Shiga toxin-producing E. coli O157:H7 rfbE
    Shiga toxin-producing E. coli stx1
    Shiga toxin-producing E. coli stx2
    Shigella ipaH
    V. parahaemolyticus toxR