MicroRNA Isolation by Trizol-Based Method and Its Stability in Stored Serum and cDNA Derivatives.

Trakunram K, Champoochana N, Chaniad P, Thongsuksai P, Raungrut P

Publication: Asian Pac J Cancer Prev (2019) • Vol 20 • Page 1641-1647PMID: 31244282View on PubMed

Purpose

This paper investigated the effects of extraction method used, serum volume, storage of serum and extracted microRNA (miRNA, miR), and freeze/thaw cycling of extracted miRNA on the levels of miR-20a, miR-145, and RNU6 in serum.

Conclusion

The RNA yield was lower when extracted using Trizol LS rather than miRNeasy but the purity (A260/280 ad A260/230) was comparable between the two methods. RNA concentration increased with increasing serum volume. Storage of serum or extracted miRNA at room temperature resulted in significant increases in the cycle threshold (CT) values for miR-20a, miR-145, and RNU6 but the magnitude of increase and significance depended on the miRNA in question. However, there was no effect of storing serum or extracted miRNA at 4°C, -20°C, or -80°C and up to four freeze/thaw cycles on CT values for miR-20a, miR-145, or RNU6.

Studies (1)

Purpose

This study investigated the effects of extraction method used, serum volume, storage of serum and extracted miRNA, and freeze/thaw cycling of extracted miRNA on the levels of miR-20a, miR-145, and RNU6 in serum. Blood was collected from healthy volunteers into Greiner Bio-One clotting tubes. After 30 min clotting at room temperature, serum was isolated by centrifugation at 3400 x g for 10 min followed by filtration through a 0.22 µm filter. Serum was aliquoted and stored at room temperature, 4°C, -20°C, or -80°C for 0, 1, 3, 5, 24, 48, or 72 h before being frozen at an unspecified temperature until RNA isolation. RNA was isolated from plasma using the miRNeasy Serum/Plasma Kit or Trizol LS. RNA concentration and purity was determined spectrophotometrically. Extracted RNA was stored for 0 or 3 months at -20°C before quantification of miR-145, miR-20a, and RNU6 by real-time PCR using the miScript SYBR Green PCR kit. The effect of freeze/thaw cycling of extracted miRNAs was investigated by thawing at 4°C for 1 h one to four times before analysis.

Summary of Findings

The RNA yield was 35% lower when extracted using Trizol LS rather than miRNeasy but the purity (A260/280 ad A260/230) was comparable between the two methods. RNA concentration increased with increasing serum volume from 9.75 ng/µL when 50 µL was used to 25.96 ng/µL when 200 µL was used. Storage of serum at room temperature resulted in a significant increase in the CT value for miR-20a and miR-145 after only 1 h (P<0.05, both) and RNU6 after 24 h (-15%, P=0.008) but no changes were observed in CT values for miR-20a, miR-145, or RNU6 when serum was stored for up to 72 h at 4°C, -20°C, or -80°C. Similarly, there was no effect of storing extracted miRNA at 4°C, -20°C, or -80°C on CT values for miR-20a, miR-145, or RNU6 but storage at room temperature resulted in higher CT values for miR-20a, miR-145, and RNU6 (P<0.05, all). Further, there was no effect of up to four freeze/thaw cycles on the CT values for miR-20a, miR-145, or RNU6.

  • Biospecimens

    FluidBlood
    FluidSerum
  • Preservation Types

    Frozen
  • Diagnoses

    Normal
  • Platforms

    RNASpectrophotometry
    RNAReal-time qRT-PCR
  • Pre-analytical Factors

    ClassificationPre-Analytical FactorValue(s)
    Biospecimen Aliquots and ComponentsAliquot size/volume
    100 µL
    150 µL
    200 µL
    50 µL
    StorageFreeze/thaw cycling
    0 cycles
    1 cycle
    2 cycles
    3 cycles
    4 cycles
    StorageStorage conditions
    As extracted miRNA
    As serum
    StorageStorage duration
    0 h
    1 h
    24 h
    3 h
    48 h
    5 h
    72 h
    StorageStorage temperature
    -20°C
    -80°C
    4°C
    Room temperature
    Analyte Extraction and PurificationAnalyte isolation method
    Trizol LS reagent
    miRNeasy mini kit
    Real-time qRT-PCR SpecificTargeted nucleic acid
    RNU6
    miR-145
    miR-20a