This paper investigated the effects of long-term frozen storage of whole blood on genomic DNA recovery, purity, and integrity. The effect of blood volume used for extraction and patient age, gender, HIV status, and cancer diagnosis on DNA yield was also examined.
The Integrity and Yield of Genomic DNA Isolated from Whole Blood Following Long-Term Storage at -30°C.
Chen WC, Kerr R, May A, Ndlovu B, Sobalisa A, Duze ST, Joseph L, Mathew CG, Babb de Villiers C
Purpose
Conclusion
The mean A260/280 ratio for all specimens (stored 2-19 y) was 1.79 indicating good quality DNA, but the mean A260/230 ratio was 1.71 suggesting the presence of proteins, contaminants, or RNA residue. No significant differences in total DNA yield were observed across the duration of storage but differences between DNA yield as measured by Qubit or in %dsDNA. Nonparametric trend analysis demonstrated a positive trend with the %dsDNA increasing with increased storage duration, but this effect was negligible after adjusting for blood volume used for extraction, and patient age, and gender. No statistically significant differences in DNA yield per mL of blood were observed between different storage durations or between specimens from cancer patients and those without cancer but a lower yield per 1 mL of blood was observed in specimens from patients that were HIV-positive than those that were HIV-negative.
Studies (1)
Purpose
This study investigated the effects of long-term frozen storage of whole blood on genomic DNA recovery, purity, and integrity. The effect of blood volume used for extraction and patient age, gender, HIV status, and cancer diagnosis on DNA yield was also examined. Blood was collected from 2758 patients into 4 mL EDTA vacutainers and stored at room temperature until transport to the lab (<24 h). Specimens were frozen and stored at -30°C for 2-19 y. Total genomic DNA was isolated using the Qiagen FlexiGene DNA Kit. DNA quantity was assessed in all specimens spectrophotometrically using NanoDrop and DNA purity was calculated using A260/280 and A260/230 ratios. DNA integrity was assessed using gel electrophoresis in 218 randomly selected specimens stored 4-19 y. dsDNA quantity was assessed by fluorometry in 200 randomly selected specimens stored 2-19 y.
Summary of Findings
The mean A260/280 ratio for all specimens (stored 2-19 y) was 1.79 indicating good quality DNA, but the mean A260/230 ratio was 1.71 suggesting the presence of proteins, contaminants, or RNA residue. Gel electrophoresis analysis revealed high-molecular-weight staining for the 218 specimens randomly selected (stored 4-19 y). The average yield as measured by NanoDrop for all specimens was 108.95 mg but the average yield for the 200 specimens measured by Qubit was 86.19 mg per specimen, indicating that ~79% of total DNA measured by spectrophotometry was dsDNA and the remaining proportion was single-stranded DNA and/or degraded DNA. No significant differences in total DNA yield as measured by Qubit (P=0.46) or in %dsDNA (P=0.10) were observed across the duration of storage. While nonparametric trend analysis for %dsDNA as quantified by Qubit demonstrated a positive trend (P<0.001) with the %dsDNA increasing with increased storage duration, this effect was negligible after adjusting for blood volume used for extraction, patient age, and gender (P=0.045). No statistically significant differences in DNA yield per mL of blood were observed between different storage durations (P=0.25) or between specimens from cancer patients and those without cancer (P=0.50) but a lower yield per 1 mL of blood was observed in specimens from patients that were HIV-positive than those that were HIV-negative (P=0.0076).
Biospecimens
FluidBloodPreservation Types
FrozenDiagnoses
AIDS/HIV-relatedNeoplasticNot specifiedNot specifiedPlatforms
DNAFluorometryDNASpectrophotometryDNAElectrophoresisPre-analytical Factors
Classification Pre-Analytical Factor Value(s) Preaquisition Diagnosis/ patient condition Cancer diagnosisHIV-negativeHIV-positiveNon-cancer diagnosisPreaquisition Patient age Range not providedPreaquisition Patient gender FemaleMaleBiospecimen Aliquots and Components Aliquot size/volume < 2 mL> 2 mLStorage Storage duration 2-19 y