This paper investigated the effects of frozen storage duration (2–11 years) on peripheral blood mononuclear cell (PBMC) viability rates, total cell counts, and live cell numbers. Correlations between total cell counts and DNA yield were also examined.
Quality of Cryopreserved Peripheral Blood Mononuclear Cells Recovered from the Hepatitis/AIDS Biobank.
Sun J, Gao M, Li K, Qin L, Sun H, Qiao G, Zhao Y, Zhang Y
Purpose
Conclusion
The median cell viability rate, total cell counts, and live cell numbers for frozen PBMCs stored for 11 y was significantly lower compared to those stored for 10, 4, or 2 y. Cell viability was positively correlated with the live cell count and total cell count. As expected, DNA yield was positively correlated with total cell count.
Studies (1)
Purpose
This study investigated the effects of frozen storage duration (2–11 years) on PBMC viability rates, total cell counts, and live cell numbers. Correlations between total cell counts and DNA yield were also examined. Peripheral blood obtained from 87 patients was obtained by an unspecified method and peripheral blood mononuclear cells (PBMCs) were separated by Ficoll density gradient centrifugation (details not provided). Cells were frozen in 90% FBS + 10% dimethyl sulfoxide at -80°C overnight before transfer to liquid nitrogen storage for 2, 4, 10, or 11 y. Frozen PBMCs were thawed in a 37°C water bath and then transferred into prewarmed medium. 20 µL of cell suspension was used to count PBMCs by acridine orange/propidium iodide (AO/PI) staining in an automated cell counter. Thirty of the specimens were randomly selected for DNA extraction using the Qiagen DNA Extraction Kit and yield was measured on a spectrophotometer.
Summary of Findings
The median cell viability rate, total cell counts, and live cell numbers for frozen PBMCs stored for 11 y was significantly lower compared to those stored for 10, 4, or 2 y (P<0.05, all). Statistical significance between specimens stored for 10 y versus 2 or 4 y was not performed. Cell viability was modestly correlated with live cell count (r=0.578, P<0.0001) and weakly correlated with total cell count (r=0.338, P=0.0003). As expected, DNA yield was positively correlated, albeit very weakly, with total cell count (r=0.1982).
Biospecimens
FluidBloodCellWhite CellsPreservation Types
FrozenDiagnoses
Not specifiedPlatforms
Cell count/volumeCoulter counterDNASpectrophotometryPre-analytical Factors
Classification Pre-Analytical Factor Value(s) Storage Storage duration 10 y11 y2 y4 y