The purpose of this paper was to investigate the effects of different extraction methods on the concentration, quality, and amplifiability of RNA from formalin-fixed paraffin-embedded (FFPE) specimens.
Against All Odds: RNA Extraction From Different Protocols Adapted to Formalin-fixed Paraffin-embedded Tissue.
Guerra JM, Monteiro RL, Gonzalez L, Kimura LM, Cirqueira CDS, de Araújo LJT
Purpose
Conclusion
The concentration of RNA was significantly higher when extraction was with phenol-chloroform followed by QIAamp and RNeasy. The ratio of absorbance at 260 to 280 was significantly higher when extracted using QIAmp than phenol-chloroform or RNeasy but there were no differences in the ratio of the absorbance at 260 to 230, PCR success, or quantification cycle (Cq) value for RNaseP.
Studies (1)
Purpose
The purpose of this study was to investigate the effects of different extraction methods on the concentration, quality, and amplifiability of RNA from FFPE specimens. Twelve blocks of formalin-fixed (10% formalin) paraffin-embedded liver, spleen, lung, and brain tissue were obtained from an archive after unspecified storage. Details of specimen procurement and processing were not provided. FFPE blocks were sectioned at 9 µm and stored frozen at −35°C for up to 7 days before extraction. Before extraction, specimens were deparaffinized in xylene and lysed in lysis buffer containing proteinase K at 55°C for 10 min, followed by 45°C overnight, and inactivation at 85°C for 10 min. RNA was then extracted from 12 FFPE replicates using each of the following methods: (1) phenol-chloroform-isoamyl alcohol with carrier RNA, (2) QIAamp viral mini kit including the Carrier AVL-RNA buffer, and (3) the RNeasy Mini Kit. RNA was quantified by spectrophotometer and stored at -34°C. Levels of 18s rRNA were quantified by RT-PCR followed by gel electrophoresis. Levels of RNAseP were quantified by real-time RT-PCR. RNA presence in the sections was confirmed by 28S rRNA chromogenic in situ hybridization (CISH) of 3 μm sections.
Summary of Findings
CISH analysis confirmed the preservation of RNA in the sections and H&E staining revealed good morphologic preservation. The concentration of RNA was significantly higher when extraction was with phenol-chloroform than with QIAamp (420.3 ng/µL versus 69.2 ng/µL, P=0.034) or RNeasy (420.3 ng/µL versus 14.7 ng/µL, P=0.015). The ratio of absorbance at 260 to 280 was significantly higher when RNA was extracted using QIAmp than phenol-chloroform (P<0.001) or RNeasy (P<0.001) but there were no differences in the ratio of the absorbance at 260 to 230. Amplification of 18s rRNA was possible in all 12 specimens, regardless of the extraction method. Further the Cq value for RNaseP did not differ significantly among the extraction methods.
Biospecimens
TissueLiverTissueLungTissueSpleenTissueBrainPreservation Types
FormalinDiagnoses
Not specifiedPlatforms
RNAReal-time qRT-PCRRNART-PCRRNASpectrophotometryRNAIn situ hybridizationMorphologyH-and-E microscopyPre-analytical Factors
Classification Pre-Analytical Factor Value(s) Analyte Extraction and Purification Analyte isolation method Phenol-chloroform-isoamyl alcoholQIAmp viral RNA mini kitRNeasy mini kitRT-PCR Specific Targeted nucleic acid 18S rRNAIn situ hybridization Specific Targeted nucleic acid 28S rRNAReal-time qRT-PCR Specific Targeted nucleic acid RNAse P