The purpose of this paper was to investigate the effects of storing blood pre- and post-centrifugation at 4°C, room temperature, or 37°C on levels of interleukin (IL)-6 in plasma and serum. The paper also investigated if the effects of post-centrifugation storage could be attenuated by the separation of the plasma or serum before storage.
Effects of blood sample handling procedures on measurable interleukin 6 in plasma and serum.
Gong Y, Liang S, Zeng L, Ni Y, Zhou S, Yuan X
Purpose
Conclusion
IL-6 levels were higher in plasma than serum but strongly correlated in matched plasma and serum. Plasma levels of IL-6 were not significantly affected by storage of blood pre- and post-centrifugation, and separated plasma at 4°C, room temperature, or 37°C. In contrast, serum levels of IL-6 were stable when blood or serum were stored at 4°C but increased when blood or serum in the same tube were stored at room temperature for 24 h or at 37°C for ≥ 8 h. However, the levels of IL-6 remained steady during subsequent storage at all three temperatures for up to 24 h when serum was separated immediately after centrifugation.
Studies (1)
Purpose
The purpose of this study was to investigate the effects of storing blood pre- and post-centrifugation at 4°C, room temperature, or 37°C on levels of IL-6 in plasma and serum and to investigate if the effects of post-centrifugation storage could be attenuated by the separation of the plasma or serum before storage. Blood was collected from a total of 45 healthy individuals into Vacutainer tubes with clot activator and K2EDTA tubes. Tubes were immediately inverted ten times. The specimens were divided into batches that used 5 different specimens (2 from females, 3 from males) for each experimental condition. Blood from fifteen donors was centrifuged immediately at 1760 x g for 15 min and stored at 4°C, room temperature, or 37°C (5 specimens each) and IL-6 levels were determined after 0, 1, 2, 4, 8, and 24 h. Blood from another 15 donors was stored at 4°C, room temperature, or 37°C (5 specimens each) for 0, 1, 2, 4, 8, and 24 h before centrifugation at 1760 x g for 15 min and then analyzed. Blood from the remaining fifteen donors was centrifuged immediately at 1760 x g for 15 min, placed in new tubes, and stored at 4°C, room temperature, or 37°C and IL-6 levels were determined after 0, 8, and 24 h. IL-6 levels were determined using an electrochemiluminescence method on Cobas e601 auto-analyzer.
Summary of Findings
IL-6 levels were higher in plasma than serum (P<0.001) but levels in serum were very strongly correlated with those in matched plasma (r=0.9180, P=0.0001). Plasma levels of IL-6 were unaffected by storage of blood at room temperature or 37°C but declined non-significantly when blood was stored at 4°C. In contrast, serum levels of IL-6 were stable when blood was stored at 4°C but increased when blood was stored at room temperature for 24 h (4.53-fold, P=0.003) or at 37°C for 8 h (17.43-fold, P=0.02) or 24 h (20.45-fold, P=0.011). Storage of plasma post-centrifugation in the same tube for up to 24 h did not affect the levels of IL-6 in plasma, regardless of temperature. However, IL-6 increased significantly when serum was stored post-centrifugation in the same tube for 8 h at 37°C (9.26-fold, P=0.006) and when stored for 24 h at room temperature (3.28-fold, P=0.015) or 37°C (9.55-fold, P=0.001). The levels of IL-6 remained steady during subsequent storage at 4°C, room temperature, and 37°C for up to 24 h when the serum was separated immediately after centrifugation.
Biospecimens
FluidBloodFluidPlasmaFluidSerumPreservation Types
None (Fresh)Diagnoses
NormalPlatforms
PeptideClinical chemistry/auto analyzerPre-analytical Factors
Classification Pre-Analytical Factor Value(s) Biospecimen Aliquots and Components Blood and blood products PlasmaSerumBiospecimen Aliquots and Components Centrifugation Centrifugation delays investigatedStorage Storage duration 0 h1 h2 h24 h4 h8 hStorage Storage temperature 37°C4°CRoom temperature