The purpose of this paper was to determine the effects of collection tube type and delayed processing on RNA concentration, purity, integrity, and thyroglobulin (TG) mRNA levels.
Stabilization of circulating thyroglobulin mRNA transcripts in patients treated for differentiated thyroid carcinoma.
Feddersen S, Bastholt L, Pedersen SM
Purpose
Conclusion
RNA yield was unaffected by storage of blood for 72 h in PAXgene tubes but increased when stored in Tempus tubes and decreased when stored in K2EDTA tubes. Although RNA integrity numbers (RINs) were unaffected by storage of blood in EDTA tubes for 72 h, RINs were significantly lower for blood stored for 72 h in PAXgene and Tempus tubes. The OD260/280 ratios were close to 2 for all specimens but were lower in blood from PAXgene tubes compared to Tempus or EDTA tubes. Relative TG levels were significantly lower in all PAXgene and EDTA specimens stored for 72 h compared to baseline but were significantly higher in 9 of 11 specimens stored for 72 h in Tempus. The authors report similar changes in the quantification cycle (Cq) of TG, glyceraldehyde 3-phosphate dehydrogenase (GAPDH), and beta-actin (ACTB) to that seen for relative expression of TG. Although most specimens showed a difference in GAPDH and ACTB normalized TG levels after 72 h at room temperature, the mean change was not significant when storage was in PAXgene or Tempus tubes. In contrast, the mean expression TG normalized to GAPDH and ACTB was significantly lower when blood was stored in EDTA tubes for 72 h.
Studies (1)
Purpose
The purpose of this study was to determine the effects of collection tube type and delayed processing on RNA concentration, purity, integrity, and TG mRNA levels. Blood was collected from 11 patients who had undergone total or near total thyroidectomy and radio-iodine ablation as treatment for differentiated thyroid carcinoma. Blood was collected into two K2EDTA, two PAXgene, and two Tempus tubes. RNA was extracted from one Tempus and one EDTA tube immediately, from one PAXgene tube after 2 h at room temperature, and from the remaining tube of each type after 72 h at room temperature. RNA was isolated from 1 mL of K2EDTA blood using TriReagent followed by further purification using the NucleoSpin RNA Clean-up XS kit. RNA was isolated from blood in PAXgene tubes using the PAXgene Blood RNA Kit. RNA was extracted from blood in Tempus tubes using the Tempus Spin RNA Isolation Kit. A DNase step (DNAse I for PAXgene and TURBO DNA-free for Tempus and EDTA) was included in all isolations. RNA concentrations were determined spectrophotometrically. Purity and integrity were assessed by bioanalyzer. RNA was reverse-transcribed using the High Capacity cDNA Reverse Transcription Kit. Levels of High Capacity cDNA Reverse Transcription Kit. Levels of TG, GAPDH, and ACTB were determined by real-time RT-PCR.
Summary of Findings
RNA yield was unaffected by storage of blood for 72 h in PAXgene tubes for 72 h but increased significantly when stored in Tempus tubes (1.8 µg/mL to 5.1 µg/mL, P=0.0143) and decreased significantly when stored in K2EDTA tubes (3.3 µg/mL to 2.1 µg/mL, P=0.0296). The concentration of RNA was significantly higher when blood was stored in Tempus tubes for 72 h than when stored in PAXgene tubes for 72 h (P=0.0011). Although RNA integrity numbers (RINs) were unaffected by storage of blood in EDTA tubes for 72 h (6.67 at 72 h versus 6.81 at 0 h), RINs were significantly lower for blood stored for 72 h in PAXgene (7.18 at 72 h versus 8.53 at 2 h, P=0.001) or Tempus (6.46 at 72 h versus 8.98 at 0 h, P=0.0002) tubes. The OD260/280 ratios were close to 2 for all specimens but were significantly lower in blood from PAXgene tubes compared to blood from Tempus (P<0.0001) or EDTA tubes (P=0.0015). Relative TG levels were significantly lower in all PAXgene and EDTA specimens stored for 72 h than in matched specimens stored for 2 h (PAXgene, mean 1.4-fold) or 0 h (EDTA, mean 15-fold). In contrast, TG levels were significantly higher in 9 of 11 specimens stored in Tempus tubes for 72 h compared to those stored for 0 h (mean 1.4-fold). The authors report similar changes in the Cq of TG, GAPDH, and ACTB to that seen for relative expression of TG. Although most specimens showed a difference in GAPDH and ACTB normalized TG levels after 72 h at room temperature, the mean change was not significant when storage was in PAXgene or Tempus tubes. In contrast, the mean expression TG normalized to GAPDH and ACTB was significantly lower when blood was stored in EDTA tubes for 72 h (P=0.0263).
Biospecimens
FluidBloodPreservation Types
PAXgeneNone (Fresh)Other PreservativeDiagnoses
NeoplasticCarcinomaPlatforms
RNASpectrophotometryRNAAutomated electrophoresis/BioanalyzerRNAReal-time qRT-PCRPre-analytical Factors
Classification Pre-Analytical Factor Value(s) Biospecimen Acquisition Type of collection container/solution K2EDTAPAXgeneTempusBiospecimen Aliquots and Components Centrifugation Centrifugation delays investigatedBiospecimen Preservation Type of fixation/preservation EDTAPAXgeneTempusStorage Time at room temperature 0 h2 h72 hReal-time qRT-PCR Specific Targeted nucleic acid ACTBGAPDHTG