Skip to main content

Relationship between formalin reagent and success rate of targeted sequencing analysis using formalin fixed paraffin embedded tissues.

Amemiya K, Hirotsu Y, Oyama T, Omata M

Publication: Clin Chim Acta (2019) • Vol 488 • Page 129-134PMID: 30395866View on PubMed

Purpose

This paper investigated the impact of fixation in 10 or 20% neutral buffered or unbuffered formalin for 1 to 7 d on DNA integrity.  It also compared next generation sequencing success in specimens fixed in 10% neutral buffered formalin (NBF) with those fixed in 20% unbuffered formalin. DNA fragmentation and NGS success rates were also compared between surgical resection and biopsy specimens from multiple tissue types.

Conclusion

DNA fragmentation was more prevalent among specimens fixed in unbuffered formalin and at a higher concentration of formalin than in those fixed in a concentration of 10% or in NBF. NGS success rates were substantially higher when specimens were fixed in 10% NBF compared to 20% unbuffered formalin (98.3 vs 34.6%), but were similar among specimens fixed in 10% NBF for 1 to 7 d. DNA fragmentation and NGS success rates were comparable among biopsies and resections and among the different tissue types evaluated.

Studies (2)

Purpose

The purpose of this study was to determine if the extent of DNA fragmentation is affected by the concentration (10%, 20%) and buffer used during formalin fixation and the duration of formalin fixation.  Surgically resected and biopsy liver specimens were dissected and fixed in 10 or 20% neural buffered formalin (NBF) or unbuffered formalin for 6 h to 7 d. Results were compared to controls that were snap-frozen in liquid nitrogen and then stored at -80°C. Tumor specimens were isolated via laser microdissection prior to DNA extraction with the QIAamp DNA FFPE kit and elution with QIAamp Mini Elute columns. DNA fragmentation was assessed by real-time PCR and the relative quantification of DNA via RQ values. RQ values reflect the ratio of a long (268 bp) to short (87 bp) amplicon, with a higher RQ value indicating better genomic DNA quality.

Summary of Findings

Based on RQ values, all FFPE specimens yielded degraded DNA compared to snap-frozen liver specimens. When specimens were fixed for 24 h, DNA fragmentation was less severe when formalin was buffered compared to unbuffered and when a lower concentration of formalin (10% versus 20%)was used.  The highest RQ values were obtained from specimens fixed in 10% NBF followed by 20% NBF, 10% unbuffered formalin, and 20% unbuffered formalin. Long DNA fragments were amplifiable when liver specimens were fixed for 3 d or less, but fixation for 7 d resulted in severe DNA fragmentation; effects were dependent on formalin composition, with the least fragmentation observed among specimens fixed in 10% NBF, 10% unbuffered formalin, 20% NBF, followed by 20% unbuffered formalin.

  • Biospecimens

    TissueLiver
  • Preservation Types

    Formalin
  • Diagnoses

    NeoplasticCarcinoma
  • Platforms

    DNAReal-time qPCR
  • Pre-analytical Factors

    ClassificationPre-Analytical FactorValue(s)
    Biospecimen PreservationConcentration of fixative
    10%
    20%
    Biospecimen PreservationTime in fixative
    1 d
    12 h
    3 d
    6 h
    7 d
    Biospecimen PreservationType of fixation/preservation
    Formalin (buffered)
    Formalin (unbuffered)
    Real-time qPCR SpecificLength of gene fragment
    268 bp
    87 bp