Skip to main content

Short-Duration Rapid Chilling of Mastectomy Specimens Does Not Interfere With Breast Cancer Biomarker and Molecular Testing.

Kumarapeli AR, Bellamy W, Olgaard E, Massoll N, Korourian S

Publication: Arch Pathol Lab Med (2019) • Vol 143 • Page 92-98PMID: 29932859View on PubMed

Purpose

The purpose of this paper was to determine if chilling a breast mastectomy specimen at -80°C for 20 min prior to formalin fixation affects DNA quantity, purity, and integrity; molecular and proteomic analyses; and histomorphology compared to results obtained with case-matched, pre-surgical formalin-fixed, paraffin-embedded (FFPE) biopsy specimens.

Conclusion

No observable differences in histomorphology, DNA purity, DNA integrity, or immunohistochemical staining of estrogen receptor (ER), progesterone receptor (PR), or HER2 were observed between case-matched pre-surgical FFPE biopsy specimens and mastectomy specimens that were chilled prior to formalin-fixation and paraffin-embedding to facilitate pre-fixation grossing.

Studies (1)

Purpose

The purpose of this paper was to determine if chilling a breast mastectomy specimen at -80°C for 20 min prior to formalin fixation affects DNA quantity and purity; successful PCR amplification of differently sized β-actin amplicons; immunohistochemical staining of ER, PR, and HER-2; and histomorphology when compared to results obtained with case-matched, pre-surgical formalin-fixed, paraffin-embedded (FFPE) biopsy specimens. A total of 95 case-matched specimen pairs (pre-surgical FFPE biopsies, mastectomy specimens chilled to facilitate grossing and the production of 4 mm thick cross sections prior to formalin-fixation and paraffin embedding) were collected and analyzed for histomorphology by hematoxylin and eosin staining, and immunohistochemical staining of ER, PR, and HER2. Additional details on formalin fixation and paraffin embedded were not provided. Immunostaining was scored as the intensity and percentage of stained tumor nuclei. Specimens from six cases were used for DNA analysis. DNA was isolated from four 10 µm-thick FFPE sections per sample using the FFPE Plus LEV DNA purification kit and an automated extractor. DNA quantity and purity were assessed by spectrophotometry. DNA integrity was determined by PCR analysis of differentially sized β-actin amplicons (100-600 bp).

Summary of Findings

Histomorphology was well preserved in mastectomy specimens that were pre-chilled at -80°C for 20 min prior to formalin fixation.  When the 95 cases with case-matched chilled mastectomy specimens and FFPE pre-surgical biopsies were compared, discordant immunohistochemical findings were observed among 1.05% of cases for ER and 0% for PR.  Among the 77 cases evaluated for HER2/neu, 0% produced discordant findings among chilled mastectomy specimens and case-matched pre-surgical biopsy specimens.  DNA isolated from pre-chilled FFPE mastectomy specimens and case-matched pre-surgical biopsies were all of acceptable purity, falling within the acceptable range of 1.6 - 1.9 (260/280 nm). PCR amplification of 300 and 400 bp fragments of β-actin was successful for all cases and specimens.

  • Biospecimens

    TissueBreast
  • Preservation Types

    Formalin
  • Diagnoses

    NeoplasticCarcinoma
  • Platforms

    DNASpectrophotometry
    DNAPCR
    MorphologyH-and-E microscopy
    ProteinImmunohistochemistry
  • Pre-analytical Factors

    ClassificationPre-Analytical FactorValue(s)
    Biospecimen AcquisitionMethod of tissue acquisition
    Core needle biopsy
    Mastectomy
    Surgical resection
    Biospecimen AcquisitionPre-preservation condition
    -80°C for 20 min
    No treatment
    PCR SpecificLength of gene fragment
    100-600 bp
    PCR SpecificTargeted nucleic acid
    β-actin
    Immunohistochemistry SpecificTargeted peptide/protein
    ER
    HER-2
    PR