This paper investigated the effects of discarding blood before collection and delayed analysis on the levels of P-ionized calcium in serum.
Is a discard tube necessary, when drawing blood for P-Ionized calcium analysis?
Novakovic V, Abdija S, Borowik T, Gredal L, Madsen KV, Jacobsen KK
Purpose
Conclusion
P-ionized calcium levels were comparable in specimens from the first (no discard) and second tube in specimens when analyzed ≤96 h although small but significant differences were observed when analyzed after 120 h. However, all except one specimen remained within the 95% limit of agreement, even after 120 h.
Studies (1)
Purpose
The purpose of this study was to investigate the effects of discarding blood before collection and delayed analysis on the levels of P-ionized calcium in serum. Blood from 100 randomly selected outpatients was obtained using a winged collection set with a 19-gauge needle into paired Vacutainer clot activator tubes with gel. Blood was not discarded prior to first collection. Serum was obtained 0.5-2 h after collection by centrifugation at 3580 x g for 4 min and pH adjusted to 7.4. Serum was stored at 4-6˚C for 24, 48, 72, 96, and 120 h before analysis on a Konelab 60i.
Summary of Findings
P-ionized calcium levels were comparable in specimens from the first and second tube in specimens when analyzed ≤96 h but were 0.0016 mmol/L lower in the second tube than the first tube when analyzed after 120 h (P=0.0068). Even after 120 h the mean difference between the first and second tube remained within the 95% limit of agreement for all specimens except one.
Biospecimens
FluidBloodFluidSerumPreservation Types
None (Fresh)Diagnoses
Not specifiedPlatforms
Electrolyte/MetalClinical chemistry/auto analyzerPre-analytical Factors