Skip to main content

Preanalytical sample handling recommendations for Alzheimer's disease plasma biomarkers.

Rózga M, Bittner T, Batrla R, Karl J

Publication: Alzheimers Dement (Amst) (2019) • Vol 11 • Page 291-300PMID: 30984815View on PubMed

Purpose

This paper investigated the effects of circadian rhythms, anticoagulant type, tube type and volume, partial tube filling, delayed centrifugation, plasma tube transfers, plasma storage (fresh, thawed of frozen), and freeze-thaw cycling on levels of the amyloid β peptides(1-40) [Aβ(1-40)] and Aβ(1-42) and total Tau (tTau) in plasma.

Conclusion

Levels of Aβ(1-40), Aβ(1-42), and tTau in plasma were affected by the time of day blood was collected, anticoagulant type, and delayed centrifugation. Levels of Aβ(1-40) and Aβ(1-42) were affected by the storage of fresh or thawed plasma but tTau levels were unaffected. tTau was affected by partial filling of the tubes and freeze-thaw cycling of plasma at -80 ˚C, but there were only minimal effects on levels of Aβ(1-40) and Aβ(1-42). There was no effect of the tube material [polypropylene (S-Monovette) versus polyethylene terephthalate (Vacutainer)], tube volume (2.7, 4.9, 8.5, 9, or 10 mL), EDTA cation (K2 or K3), presence of gel separator, frozen storage temperature, or transfer of plasma between tubes.

Studies (4)

Purpose

The purpose of this study was to determine if collection day or time of day affect levels of Aβ(1-40), Aβ(1-42), and tTau in plasma. Blood was collected from eight healthy volunteers into 9 mL K3EDTA tubes at 8 AM, noon, and 3 PM on Day 1 and at 8 AM only on Days 2 and 7. Within 10 min of collection, blood was centrifuged for 10 min at 2000 x g. Plasma was transferred to a polypropylene tube, inverted several times, and aliquoted. Levels of Aβ(1-40), Aβ(1-42), and tTau were quantified using a Roche Cobas e 601 analyzer and were normalized to levels at 8 AM on Day 1.

Summary of Findings

Levels of Aβ(1-40), and Aβ(1-42) were 5-9% higher and tTau approximately 8% lower in specimens collected at noon and 3 PM on Day 1 than in specimens collected at 8 AM, but levels of all three were comparable at 8 AM on the three days.

 

  • Biospecimens

    FluidBlood
    FluidPlasma
  • Preservation Types

    None (Fresh)
  • Diagnoses

    Normal
  • Platforms

    PeptideClinical chemistry/auto analyzer
    ProteinClinical chemistry/auto analyzer
  • Pre-analytical Factors

    ClassificationPre-Analytical FactorValue(s)
    Biospecimen AcquisitionTime of biospecimen collection
    12 PM on day 1
    3 PM on day 1
    8 AM on day 1
    8 AM on day 2
    8 AM on day 3