Skip to main content

A Study of Pre-Analytical Variables and Optimization of Extraction Method for Circulating Tumor DNA Measurements by Digital Droplet PCR.

Cavallone L, Aldamry M, Lafleur J, Lan C, Gonzalez Ginestet P, Alirezaie N, Ferrario C, Aguilar-Mahecha A, Basik M

Publication: Cancer Epidemiol Biomarkers Prev (2019)PMID: 30824523View on PubMed

Purpose

This paper investigated the effects of extraction method, blood collection tube type, and centrifugation protocol on the recovery of cell-free DNA (cfDNA) from blood. The effects of preamplification and whole genome amplification (WGA) on the variant allele frequency (VAF) of cfDNA and tumor DNA was also investigated.

Conclusion

The percentage of cfDNA recovered differed slightly between genes but the yield was always highest using the in-house hybrid method of the QIAamp circulating nucleic acid (CNA) and DSP kits. Slightly more copies of TP53 were obtained from EDTA plasma than CTAD plasma, but the difference was not significant. There was no effect of freezing plasma for 2 weeks between centrifugation steps or of the speed of the second centrifugation on the amount of cfDNA obtained. The VAFs were very strongly correlated between preamplified and nonpreamplified plasma as well as tumor DNA specimens. In contrast, VAFs were strongly correlated between WGA and unamplified tumor DNA specimens but not plasma DNA specimens.

Studies (3)

Purpose

The purpose of this study was to compare the efficiency of cfDNA extraction using the QIAamp circulating nucleic acid (CNA) kit, the QIAamp DSP virus kit, and an in-house hybrid protocol. Plasma was obtained from a healthy patient by centrifugation of K2EDTA blood at 1500 x g followed by immediate centrifugation at 16000 x g. Plasma was spiked with known amounts of reference DNA from cell lines or tumors from breast cancer patients participating in a clinical trial. cfDNA was extracted from 1 mL of plasma using the QIAamp CNA and DSP kits following the manufacturer’s instructions or using an in-house hybrid protocol. The in-house hybrid protocol included a 15 min Proteinase K digestion at 56˚C using the buffer from the DSP kit with the addition of carrier RNA from the CNA kit, addition of ACB buffer, vortexing, incubation on ice, followed by purification using the DSP kit MiniElute columns, and elution with AVE buffer. DNA was stored at -20˚C until DNA quantification by droplet digital (dd)PCR amplification of CDH5, MAP1LC3B, PARK2, TP53, and ROBO2.

Summary of Findings

The average recovery of the spiked-in DNA was significantly higher using the hybrid method than the QIAamp CNA (89% versus 46.9%, P<0.0001) or DSP (89% versus 75.4%, P<0.01) kits. When each of the five variants were examined individually, the efficiency varied between the genes but was always highest with the hybrid protocol and lowest with the CNA protocol.

  • Biospecimens

    FluidPlasma
  • Preservation Types

    None (Fresh)
  • Diagnoses

    Normal
  • Platforms

    DNADigital PCR
  • Pre-analytical Factors

    ClassificationPre-Analytical FactorValue(s)
    Analyte Extraction and PurificationAnalyte isolation method
    Hybrid protocol
    QIAamp CNA kit
    QIAamp DSP virus kit
    Digital PCR SpecificTargeted nucleic acid
    CDH5
    MAP1LC3B
    PARK2
    ROBO2
    TP53