Skip to main content

An efficient and cost-effective method for purification of small sized DNAs and RNAs from human urine.

Zainabadi K, Dhayabaran V, Moideen K, Krishnaswamy P

Publication: PLoS One (2019) • Vol 14 • Page e0210813PMID: 30721243View on PubMed

Purpose

This paper optimized an in-house cell-free DNA extraction protocol and an alternative protocol for larger volumes. The location and size distribution of DNA in urine and the effects of storage at cooler temperatures or preservation on the stability of cell-free DNA in urine were also investigated.

Conclusion

For volumes of less than 400 µL urine, the addition of BSA to the urine before adding a lysis solution containing 3 M guanidine thiocyanate, 33% isopropanol, and 0.5% 2-mercaptoethanol added at a ratio of 1:1 and application to a Nunc plate resulted in the highest DNA yields. Interestingly, the pH of the lysis buffer was shown to specifically affect the recovery of small DNA fragments. For larger urine volumes (>800 µL), the addition of 250 µL silica to the lysate and application to Pall GHP 0.45 µm size-exclusion plates resulted in the highest DNA yields. Importantly, as the input volume was adjusted from 250 µL to 2.5 mL and 25 mL, the average cycle threshold (CT) values decreased by 2.5 and 5.2 cycles, respectively. The supernatants and pellets produced by centrifugation at 7500 rpm and 15000 rpm had similar levels of DNA, but DNA >241 bp was less abundant in the supernatant than the pellet.  Average CT values increased when urine was stored for 1 week at room temperature. This increase was partially attenuated by the addition of EDTA with or without sodium azide and by refrigeration; however, the addition of the lysis buffer containing 3 M guanidine thiocyanate and 33% isopropanol resulted in lower CT values than even urine frozen at -20 or -80˚C. Further study showed that 3 M guanidine thiocyanate and 33% isopropanol provided comparable stability to the Qiagen RLT buffer with isopropanol for up to 2 weeks.

Studies (4)

Purpose

This study investigated the effects of lysis buffer composition, ratio of urine to lysis buffer, addition of BSA or casein to the urine, filtration plate type, and wash solution components on the recovery of spiked-in DNA fragments of different sizes from urine. Excess first-morning urine from an unspecified number of healthy males were pooled and spiked with 100 bp DNA ladder. Lysis buffer containing guanidine thiocyanate (3 M, 4 M, or 6 M) or 3M guanidine hydrochloride, 20-33% isopropanol or ethanol, 0-1% 2-mercaptoethanol in addition to 20 mM TrisHCl, 50 mM EDTA, and 4% Triton-X100 at pH 6.0 or 6.5 was mixed with urine at a ratio of 1:1 or 2:1. The mixture was placed into filter plates (Nunc, Omega EZ, Econospin, or Pureplate), centrifuged at 2250 x g for 1 min, and washed in a solution containing lysis buffer without 2-mercaptoethanol. The plate was centrifuged again at 2250 x g for 1 min; washed in 25% ethanol, 25% isopropanol, 10 mM NaCl, and 10 mM Tris pH 7.4; and centrifuged again at 2250 x g for 2 min. The plate was then dried and DNA was eluted with TE buffer (pH 8.0). DNA ladder was quantified by electrophoresis. Extracted DNA was reverse-transcribed and total DNA isolated was quantified by real-time PCR amplification of actin.

Summary of Findings

Recovery of DNA larger than 100 bp was not affected by the pH of the lysis buffer, but recovery of the 100 bp band was only possible when the pH of the lysis buffer was ≤6.5 or contained ethanol (15 or 20%). The average CT for actin was lowest when the lysis solution contained 3 M guanidine thiocyanate (rather than 4 M or 6 M guanidine thiocyanate or 3 M guanidine hydrochloride), 33% isopropanol (rather than 20% isopropanol or 20 or 33% ethanol), and 0.5% 2-mercaptoethanol (rather than 0%, 0.1%, 0.25%, 0.33%, or 1%) and was used at a ratio of 1:1 (rather than 2:1). There was no effect of using a lysis buffer with a pH of 6.0 versus 6.5 on the average CT value of actin. Interestingly, the addition of BSA to the lysis buffer had no effect or increased the average CT, but adding BSA to the urine directly resulted in a lower average actin CT with the lowest average CT achieved with the addition of 1 or 3.3 mg/ml (compared with 0, 0.1, 0.33, or 10 mg/mL) to the urine depending on the plate used. The addition of isopropanol to the lysis buffer only affected the average CT value when a reverse-transcription step was included, indicating it enhanced the co-purification of RNA. In conjunction with the optimized lysis buffer, the lowest average CT value of actin for combined lysis urine volumes of ≤800 µL was when Nunc 96-well filter plates were used (compared with Omega EZ, Econospin, or Pureplate). Interestingly, the components of the wash solution (0% or 0.5% 2-mercaptoethanol, 0.1 mg/mL or 1 mg/mL BSA, or 0.1 mg/mL or 1 mg/mL α-casein) had little to no effect on the average CT value of actin (all changes were within SD).

  • Biospecimens

    FluidUrine
  • Preservation Types

    None (Fresh)
  • Diagnoses

    Normal
  • Platforms

    DNAElectrophoresis
    DNAReal-time qPCR
  • Pre-analytical Factors

    ClassificationPre-Analytical FactorValue(s)
    Biospecimen Aliquots and ComponentsBiospecimen components
    0 mg/mL BSA added to urine
    0.1 mg/mL BSA added to urine
    0.33 mg/mL BSA added to urine
    1 mg/mL BSA added to urine
    10 mg/mL BSA added to urine
    3.3 mg/mL BSA added to urine
    Analyte Extraction and PurificationAnalyte isolation method
    Lysis buffer containing 3 M guanidine thiocyanate and 20% isopropanol
    Lysis buffer containing 3 M guanidine thiocyanate and 33% isopropanol
    Lysis buffer containing 4 M guanidine thiocyanate and 20% isopropanol
    Lysis buffer containing 4 M guanidine thiocyanate and 33% isopropanol
    Lysis buffer containing 6 M guanidine thiocyanate and 20% isopropanol
    Lysis buffer containing 6 M guanidine thiocyanate and 33% isopropanol
    Lysis buffer pH 6.0
    Lysis buffer pH 6.5
    Lysis buffer pH 7.5
    Lysis buffer with 0% 2-mercaptoethanol
    Lysis buffer with 0.1% 2-mercaptoethanol
    Lysis buffer with 0.25% 2-mercaptoethanol
    Lysis buffer with 0.33% 2-mercaptoethanol
    Lysis buffer with 0.5% 2-mercaptoethanol
    Lysis buffer with 1% 2-mercaptoethanol
    Lysis to urine 1:1
    Lysis to urine 2:1
    Analyte Extraction and PurificationAnalyte purification
    Econospin
    Nunc plate
    Omega EZ
    Pureplate
    Analyte Extraction and PurificationWashing
    Containing 0% 2-mercaptoethanol
    Containing 0.1 mg/ mL α-casein
    Containing 0.1 mg/mL BSA
    Containing 0.5% 2-mercaptoethanol
    Containing 1 mg/ mL α-casein
    Containing 1 mg/mL BSA