Evaluation of commercial kits for purification of circulating free DNA.

Diefenbach RJ, Lee JH, Kefford RF, Rizos H

Publication: Cancer Genet (2018) • Vol 228-229 • Page 21-27PMID: 30553469View on PubMed

Purpose

This paper compared extraction kits and fragment size on the recovery of spiked-in DNA from plasma and compared the yield of endogenous cfDNA using two kits.

Conclusion

Average recovery of spiked-in DNA was significantly higher when extraction was with the spin column-based QIAamp Circulating Nucleic Acid kit and Plasma/Serum Cell-Free Circulating DNA Purification Midi kit than when extracted using the magnetic bead based kits. Among the magnetic bead-based kits, the QIAamp MinElute ccfDNA Mini kit resulted in the highest recovery rates. All of the kits examined recovered spiked-in DNA fragments of 50-808 bp but none were able to efficiently recover the 25 bp fragment of spiked-in DNA. Consistent levels of recovery of fragments between 75-808 bp were observed for all kits with the exception of the NextPrep-Mag cfDNA Isolation kit which showed decreasing recovery with increasing fragment size of more than 200 bp.

Extraction of cfDNA with QIAamp Circulating Nucleic Acid kit yielded significantly more copies of the endogenous NRAS and higher recovery of spiked-in BRAF mutated DNA than the QIAamp MinElute cfDNA Mini kit; however, the recovery of spiked-in mutated BRAF was only significantly different when the spiked-in DNA was undiluted.

Studies (2)

Purpose

This study compared extraction kits and fragment size on the recovery of spiked-in DNA from plasma. Blood from four healthy individuals was immediately centrifuged at 800 x g for 15 min followed by centrifugation of the supernatant in a new tube at 1600 x g for 10 min. Plasma was immediately aliquoted and stored at -80˚C. Three 1 mL aliquots of plasma was spiked with 500 ng/ml of low molecular weight DNA ladder while the remaining aliquot was left unspiked. cfDNA was extracted from pooled plasma using each of the following kits: QIAamp Circulating nucleic acid kit, Plasma/Serum Cell-Free Circulating DNA Purification Midi kit, QIAamp MinElute ccfDNA Mini kit; Maxwell RSC ccfDNA Plasma kit, MagMAX cell-free DNA isolation kit, NextPrep-Mag cfDNA Isolation kit. Fragment size recovery was determined using an Experion automated electrophoresis system (running a DNA 1K analysis and comparing the purified amount to the input amount). The average recovery was based on the recovery of each individual fragment size.     

Summary of Findings

Average recovery of spiked-in DNA was significantly higher when extraction was with the spin column-based QIAamp Circulating Nucleic Acid kit and Plasma/Serum Cell-Free Circulating DNA Purification Midi kit than when extracted using the magnetic bead-based kits (P<0.001, all). Among the magnetic bead-based kits, the QIAamp MinElute ccfDNA Mini kit resulted in the highest recovery rates and the NextPrep-Mag cfDNA Isolation kit the lowest recovery rates. All of the kits examined recovered spiked-in DNA fragments of 50-808 bp but none were able to efficiently recover the 25 bp fragment of spiked-in DNA. Consistent levels of recovery of fragments between 75-808 bp were observed for all kits with the exception of the NextPrep-Mag cfDNA Isolation kit which showed decreasing recovery with increasing fragment size of more than 200 bp.

  • Biospecimens

    FluidPlasma
  • Preservation Types

    Frozen
  • Diagnoses

    Normal
  • Platforms

    DNAAutomated electrophoresis/Bioanalyzer
  • Pre-analytical Factors

    ClassificationPre-Analytical FactorValue(s)
    Analyte Extraction and PurificationAnalyte isolation method
    MagMAX cell-free DNA isolation kit
    Maxwell RSC ccfDNA plasma kit
    NextPrep-Mag cfDNA isolation kit
    Plasma/serum cell-free circulating DNA Purification midi kit
    QIAamp circulating nucleic acid kit
    QIAamp minElute ccfDNA mini kit